[1]彭莉,宋鑫,鄢苏鹏,等.基于PPG收缩期上升波形特征参数的无创血压检测模型[J].中国医学物理学杂志,2022,39(3):333-340.[doi:DOI:10.3969/j.issn.1005-202X.2022.03.013]
 PENG Li,SONG Xin,YAN Supeng,et al.Noninvasive blood pressure measurement model based on characteristic parameters of PPG systolic upstroke waveform[J].Chinese Journal of Medical Physics,2022,39(3):333-340.[doi:DOI:10.3969/j.issn.1005-202X.2022.03.013]
点击复制

基于PPG收缩期上升波形特征参数的无创血压检测模型()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
39卷
期数:
2022年第3期
页码:
333-340
栏目:
医学信号处理与医学仪器
出版日期:
2022-03-28

文章信息/Info

Title:
Noninvasive blood pressure measurement model based on characteristic parameters of PPG systolic upstroke waveform
文章编号:
1005-202X(2022)03-0333-08
作者:
彭莉宋鑫鄢苏鹏魏良龚渝顺李永勤
陆军军医大学生物医学工程与影像医学系, 重庆 400038
Author(s):
PENG Li SONG Xin YAN Supeng WEI Liang GONG Yushun LI Yongqin
Department of Biomedical Engineering and Imaging Medicine, Army Medical University, Chongqing 400038, China
关键词:
光电容积脉搏波血压检测收缩期上升波形特征参数
Keywords:
Keywords: photoplethysmography blood pressure measurement systolic upstroke waveform characteristic parameter
分类号:
R318
DOI:
DOI:10.3969/j.issn.1005-202X.2022.03.013
文献标志码:
A
摘要:
旨在提出一种基于光电容积脉搏波(PPG)收缩期上升波形(SUW)特征提取的血压计算模型。首先,采集130例成年志愿者的II导心电图、手指PPG信号以及袖带血压值。数据被随机分为训练集(共80例,其中46例血压正常)和测试集(共50例,其中35例血压正常)。然后从PPG信号的SUW中提取时间、面积、斜率最大点与波谷点连线与时间轴夹角的正切值、上升期占脉宽的比例等特征,采用偏最小二乘回归法分别建立收缩压和舒张压的检测模型。最后与基于脉冲到达时间(PAT)的模型以及PAT联合PPG的模型进行对比。结果显示,本模型计算的收缩压和舒张压与参考值的相关系数分别为0.80和0.62,判断血压异常的准确率为90%。这些指标均显著高于基于PAT和PAT联合PPG参数的血压模型(P<0.05)。研究表明,基于PPG收缩上升波形特征参数的无创血压检测模型具有较好的鲁棒性和较强的异常血压检测能力。
Abstract:
Abstract: A model for noninvasive measurement of blood pressure based on the characteristics of the systolic upstroke waveform (SUW) of photoplethysmography (PPG) is proposed in this study. Firstly, lead II electrocardiogram (ECG), finger PPG signals and the blood pressure measured from a cuff-base electronic sphygmomanometer were recorded from 130 adult volunteers, and the data were randomly divided into a training set (n=80, 46 of which had normal blood pressure) and a test set (n=50, 35 of which had normal blood pressure). Some characteristics, such as upstroke time, area under SUW, tangent of the angle between the line of the maximum slope point to the trough point and the time axis, and the ratio of upstroke period to pulse width, were extracted from the SUW of PPG. The measurement models of systolic pressure and diastolic pressure were established by partial least square regression method. Finally, the performance of the proposed method was compared with the model based on pulse arrival time (PAT) and the model based on PAT combined with PPG. The correlation coefficients between the calculation results by the proposed model and the reference values were 0.80 and 0.62 for systolic pressure and diastolic pressure, respectively. The accuracy of the proposed model in finding abnormal blood pressure was 90%. These indicators were all significantly higher than those obtained by the model based on PAT combined with PPG (P<0.05). The study reveals that the SUW-based noninvasive blood pressure measurement model has improved robustness and better performance in finding abnormal blood pressure.

相似文献/References:

[1]文 苗,王 成,白丽红,等.基于DTCWT和cICA的光电容积脉搏波运动干扰消除算法[J].中国医学物理学杂志,2015,32(02):229.[doi:10.3969/j.issn.1005-202X.2015.02.018]
[2]田树香,朱健铭,陈真诚,等.一种新的人体呼吸波采集方法与实现[J].中国医学物理学杂志,2014,31(05):5169.[doi:10.3969/j.issn.1005-202X.2014.05.016]
[3]石波,刘胜洋,陈建方,等.线性回归算法提取脉搏血氧特征值初步验证[J].中国医学物理学杂志,2013,30(01):3913.[doi:10.3969/j.issn.1005-202X.2013.01.019]
[4]雷恒波,郭友达,莫镜清,等.基于人脸视频的光电容积脉搏波信号获取与处理[J].中国医学物理学杂志,2016,33(11):1178.[doi:10.3969/j.issn.1005-202X.2016.11.019]
 [J].Chinese Journal of Medical Physics,2016,33(3):1178.[doi:10.3969/j.issn.1005-202X.2016.11.019]
[5]陈真诚,宋浩,朱健铭,等. 基于光电容积脉搏波的呼吸监测系统研究[J].中国医学物理学杂志,2019,36(5):579.[doi:DOI:10.3969/j.issn.1005-202X.2019.05.017]
 CHEN Zhencheng,SONG Hao,ZHU Jianming,et al. Respiration monitoring system based on photolethysmography[J].Chinese Journal of Medical Physics,2019,36(3):579.[doi:DOI:10.3969/j.issn.1005-202X.2019.05.017]
[6]张浩强,安蒙蒙,卜朝晖,等.基于超声回波信号的指端脉搏波提取[J].中国医学物理学杂志,2020,37(10):1306.[doi:DOI:10.3969/j.issn.1005-202X.2020.10.016]
 ZHANG Haoqiang,AN Mengmeng,BU Zhaohui,et al.Fingertip pulse wave extraction based on ultrasonic echo signal[J].Chinese Journal of Medical Physics,2020,37(3):1306.[doi:DOI:10.3969/j.issn.1005-202X.2020.10.016]
[7]张悦,陈真诚,梁永波,等.基于光电容积脉搏波的心房颤动识别方法[J].中国医学物理学杂志,2020,37(11):1416.[doi:DOI:10.3969/j.issn.1005-202X.2020.11.014]
 ZHANG Yue,CHEN Zhencheng,LIANG Yongbo,et al.Atrial fibrillation identification based on photoplethysmography[J].Chinese Journal of Medical Physics,2020,37(3):1416.[doi:DOI:10.3969/j.issn.1005-202X.2020.11.014]
[8]黄益平,陈真诚,梁永波,等.基于脉搏波的呼吸频率计算方法[J].中国医学物理学杂志,2021,38(9):1124.[doi:10.3969/j.issn.1005-202X.2021.09.014]
 HUANG Yiping,CHEN Zhencheng,LIANG Yongbo,et al.Calculation methods of respiratory rate based on PPG[J].Chinese Journal of Medical Physics,2021,38(3):1124.[doi:10.3969/j.issn.1005-202X.2021.09.014]
[9]潘嘉婷,梁丽诗,陈真诚.基于Bi-UNet的无创动脉血压波形重建算法[J].中国医学物理学杂志,2024,41(1):66.[doi:DOI:10.3969/j.issn.1005-202X.2024.01.010]
 PAN Jiating,LIANG Lishi,CHEN Zhencheng,et al.Non-invasive arterial blood pressure waveform reconstruction algorithm based on Bi-UNet[J].Chinese Journal of Medical Physics,2024,41(3):66.[doi:DOI:10.3969/j.issn.1005-202X.2024.01.010]

备注/Memo

备注/Memo:
【收稿日期】2021-11-28 【基金项目】陆军后勤科研项目(BLJ20J006-1);国家重点研发计划(2021YFC0122400) 【作者简介】彭莉,硕士研究生,主要从事生物医学信号检测处理研究,E-mail: 1623913414@qq.com 【通信作者】李永勤,教授,博士生导师,主要从事生物医学信号检测处理、现代医学仪器关键技术研究,E-mail: lyq@tmmu.edu.cn
更新日期/Last Update: 2022-03-28