[1]傅博,吴建语,沈佳鹏,等.IMRT、sIMRT及3DCRT在胸中段食管癌放疗中的应用比较[J].中国医学物理学杂志,2022,39(10):1208-1212.[doi:DOI:10.3969/j.issn.1005-202X.2022.10.005]
 FU Bo,WU Jianyu,SHEN Jiapeng,et al.Comparison among IMRT, sIMRT and 3DCRT in radiotherapy for middle thoracic esophageal cancer[J].Chinese Journal of Medical Physics,2022,39(10):1208-1212.[doi:DOI:10.3969/j.issn.1005-202X.2022.10.005]
点击复制

IMRT、sIMRT及3DCRT在胸中段食管癌放疗中的应用比较()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
39卷
期数:
2022年第10期
页码:
1208-1212
栏目:
医学放射物理
出版日期:
2022-11-02

文章信息/Info

Title:
Comparison among IMRT, sIMRT and 3DCRT in radiotherapy for middle thoracic esophageal cancer
文章编号:
1005-202X(2022)10-1208-05
作者:
傅博1吴建语1沈佳鹏1阮必顺1许锦慧1龙泉先1何玉凤1彭志刚2
1.钦州市第二人民医院肿瘤科, 广西 钦州 535000; 2.广西医科大学第一附属医院肿瘤内科, 广西 南宁 530021
Author(s):
FU Bo1 WU Jianyu1 SHEN Jiapeng1 RUAN Bishun1 XU Jinhui1 LONG Quanxian1 HE Yufeng1 PENG Zhigang2
1. Department of Oncology, The Second Peoples Hospital of Qinzhou, Qinzhou 535000, China 2. Department of Oncology, The First Affiliated Hospital of Guangxi Medical University, Nanning 530021, China
关键词:
调强放疗简化调强放疗三维适形放疗胸中段食管癌
Keywords:
Keywords: intensity-modulated radiotherapy simplified intensity-modulated radiotherapy three-dimensional conformal radiotherapy middle thoracic esophageal cancer
分类号:
R816.5
DOI:
DOI:10.3969/j.issn.1005-202X.2022.10.005
文献标志码:
A
摘要:
目的:探讨调强放疗(IMRT)、简化调强放疗(sIMRT)及三维适形放疗(3DCRT)在胸中段食管癌放疗中的应用比较。方法:回顾性选取胸中段食管癌患者105例,根据患者所接受的放疗方式分为IMRT组(n=33)、sIMRT组(n=40)及3DCRT组(n=32),比较各组靶区2%体积的器官所受照射剂量(D2)、D50、D98、均匀性指数(HI)和适形度指数(CI)差异,双肺接受5 Gy剂量照射的肺体积占全肺总体积的百分比(V5)、V10、V20、脊髓最大剂量(Dmax)和心脏平均剂量(Dmean)等。结果:IMRT组和sIMRT组D2、D50、D98和HI分别为(6 659.43±161.15) cGy和(6 603.55±145.54) cGy、(6 312.26±132.20) cGy和(6 289.94±121.17) cGy、(5 815.43±114.41) cGy和(5 801.16±120.03) cGy、(1.09±0.04)和(1.08±0.03),显著高于3DCRT组(P<0.05),CI分别为(0.71±0.02)和(0.72±0.03),显著低于3DCRT组(P<0.05);IMRT组、sIMRT组和3DCRT组双肺V5、V10、V20和脊髓Dmax比较差异无统计学意义(P>0.05);IMRT组和sIMRT组心脏Dmean分别为(784.69±101.16) cGy和(796.79±112.28) cGy,显著低于3DCRT组(P<0.05);sIMRT组机器跳数和子野数目分别为(432.24±71.19) MU和(18.03±5.56),显著低于IMRT组和3DCRT组(P<0.05);IMRT组机器跳数和子野数目分别为(501.16±78.98) MU和26.65±7.140,显著低于3DCRT组(P<0.05);IMRT组、sIMRT组和3DCRT组骨髓抑制、放射性肺炎、放射性食管炎和肺纤维化发生率比较差异无统计学意义(P>0.05);IMRT组、sIMRT组和3DCRT组放疗疗效比较差异无统计学意义(P>0.05)。结论:3DCRT、IMRT和sIMRT靶区剂量参数均可满足临床要求,其中sIMRT心脏受照剂量、机器跳数低,临床上可优先选择sIMRT计划。
Abstract:
Abstract: Objective To compare the dosimetric differences among intensity-modulated radiotherapy (IMRT), simplified intensity-modulated radiotherapy (sIMRT) and three-dimensional conformal radiotherapy (3DCRT) for middle thoracic esophageal cancer. Methods According to the radiotherapy techniques, 105 patients with middle thoracic esophageal cancer were divided into IMRT group (n=33), sIMRT group (n=40) and 3DCRT group (n=32). The D2, D50, D98, homogeneity index (HI) and conformity index (CI) of target areas, the V5, V10, V20 of both lungs, the maximum dose (Dmax) to spinal cord and the mean dose (Dmean) to heart were compared among different groups. Results The D2, D50, D98 and HI in IMRT group and sIMRT group were (6 659.43±161.15) cGy and (6 603.55±145.54) cGy, (6 312.26±132.20) cGy and (6 289.94±121.17) cGy, (5 815.43±114.41) cGy and (5 801.16±120.03) CGy, (1.09±0.04) and (1.08±0.03), respectively, which were significantly higher than those in 3DCRT group (P<0.05). The CI was (0.71±0.02) in IMRT group and (0.72±0.03) in sIMRT group, significantly lower than that in 3DCRT group (P<0.05). There were no significant differences in the V5, V10, V20 of both lungs and the Dmax to spinal cord among IMRT group, sIMRT group and 3DCRT group (P>0.05). The Dmean to heart was (784.69±101.16) cGy in IMRT group and (796.79±112.28) cGy in sIMRT group, significantly lower than that in 3DCRT group (P<0.05). The monitor units and number of subfields in sIMRT group were (432.24±71.19) MU and (18.03±5.56), which were significantly lower than those in IMRT group and 3DCRT group (P<0.05). The monitor units and number of subfields in IMRT group were (501.16±78.98) MU and (26.65±7.140), respectively, which were significantly lower than those in 3DCRT group (P<0.05). The differences in the incidences of bone marrow transplantation, radiation pneumonia, radiation esophagetis, pulmonary fibrosis among IMRT group, sIMRT group and 3DCRT group were trivial (P>0.05), and there was no significant difference in radiotherapy efficacy among IMRT group, sIMRT group and 3DCRT group (P>0.05). Conclusion 3DCRT, IMRT and sIMRT can all meet the clinical requirements for dosimetric parameters, and among them, sIMRT is preferred in clinical practice because of the low cardiac radiation dose and monitor units.

相似文献/References:

[1]张富利,王雅棣,许卫东,等.应用两种三维探测器阵列进行螺旋断层调强放疗计划剂量验证[J].中国医学物理学杂志,2015,32(02):218.[doi:10.3969/j.issn.1005-202X.2015.02.015]
[2]王捷,裴曦,曹瑞芬,等.一种快速调强放射治疗直接子野优化方法[J].中国医学物理学杂志,2015,32(01):4.[doi:10.3969/j.issn.1005-202X.2015.01.002]
[3]曾 彪,张九堂,席许平.单中心上下半野调强放射治疗的物理剂量验证[J].中国医学物理学杂志,2015,32(01):17.[doi:10.3969/j.issn.1005-202X.2015.01.005]
[4]李珠明,崔玉琴,白晓平,等.多通道剂量测量仪在调强放疗剂量检测中的应用[J].中国医学物理学杂志,2014,31(01):4600.[doi:10.3969/j.issn.1005-202X.2014.01.002]
[5]李丹明,孙新臣,张 胜,等.食道癌患者心脏图谱指导下心脏勾画的一致性研究[J].中国医学物理学杂志,2014,31(03):4857.[doi:10.3969/j.issn.1005-202X.2014.03.003]
[6]陈广涛,汪 淇,刘亚强,等.TrueBeam加速器射野准直器跟随功能在鼻咽癌固定野调强放疗和容积旋转调强放疗中的应用[J].中国医学物理学杂志,2014,31(03):4865.[doi:10.3969/j.issn.1005-202X.2014.03.005]
[7]雷怀宇,张书旭.乏氧显像及其在放射治疗中的应用研究[J].中国医学物理学杂志,2014,31(04):4975.[doi:10.3969/j.issn.1005-202X.2014.04.001]
[8]苏清秀,张 矛,金海国,等.比较调强放射治疗与三维适形放疗治疗中下段食管癌时心脏和冠状动脉的受量[J].中国医学物理学杂志,2014,31(05):5139.[doi:10.3969/j.issn.1005-202X.2014.05.010]
[9]周瑛瑛,邱小平,狄晓云,等."Pretend"Bolus在乳腺癌根治术后调强放疗应用中的剂量学研究[J].中国医学物理学杂志,2013,30(01):3848.[doi:10.3969/j.issn.1005-202X.2013.01.003]
[10]蒋晓芹,段宝风,艾平,等.基于图谱库的自动轮廓勾画软件(ABAS)在鼻咽癌调强放疗中的应用[J].中国医学物理学杂志,2013,30(02):3997.[doi:10.3969/j.issn.1005-202X.2013.02.008]
[11]刘建庭,王晋丽,郭瑞嵩,等.简化调强技术在脑转移瘤外照射中应用的剂量学研究[J].中国医学物理学杂志,2014,31(06):5244.[doi:10.3969/j.issn.1005-202X.2014.06.005]

备注/Memo

备注/Memo:
【收稿日期】2022-03-12 【基金项目】中华国际科学交流基金会检验检测科技专项(Z2020LGX001) 【作者简介】傅博,副主任医师,研究方向:肿瘤内科,E-mail: ffxf1983@163.com 【通信作者】彭志刚,主任医师,研究方向:血液及消化系统肿瘤,E-mail: zhi159086@foxmail.com
更新日期/Last Update: 2022-10-27