[1]吴建篪,邓婷,赵罂.自动计划与人工计划在宫颈癌术后VMAT放疗中的剂量学比较[J].中国医学物理学杂志,2020,37(8):989-992.[doi:DOI:10.3969/j.issn.1005-202X.2020.08.009]
 WU Jianchi,DENG Ting,ZHAO Ying.Dosimetric comparison between automatic planning and manual planning in volumetric modulated arc therapy of cervical cancer[J].Chinese Journal of Medical Physics,2020,37(8):989-992.[doi:DOI:10.3969/j.issn.1005-202X.2020.08.009]
点击复制

自动计划与人工计划在宫颈癌术后VMAT放疗中的剂量学比较()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
37
期数:
2020年第8期
页码:
989-992
栏目:
医学放射物理
出版日期:
2020-08-27

文章信息/Info

Title:
Dosimetric comparison between automatic planning and manual planning in volumetric modulated arc therapy of cervical cancer
文章编号:
1005-202X(2020)08-0989-04
作者:
吴建篪1邓婷1 赵罂2
1.郴州市第一人民医院妇科, 湖南 郴州 423000; 2.广西柳州市妇幼保健院门诊, 广西 柳州 545001
Author(s):
WU Jianchi1 DENG Ting1 ZHAO Ying2
1. Department of Gynaecology, Chenzhou No.1 Peoples Hospital, Chenzhou 423000, China 2. Outpatient Department, Liuzhou Maternity and Child Healthcare Hospital, Liuzhou 545001, China
关键词:
宫颈癌自动计划人工计划容积弧形调强放射剂量
Keywords:
Keywords: cervical cancer automatic planning manual planning volumetric modulated arc therapy radiation dose
分类号:
R815
DOI:
DOI:10.3969/j.issn.1005-202X.2020.08.009
文献标志码:
A
摘要:
目的:观察并比较自动计划与人工计划在宫颈癌术后患者容积弧形调强(VMAT)中的剂量学参数,对自动计划应用于临床宫颈癌术后放疗中的可行性进行研究。方法:选取2018年11月~2019年11月郴州市第一人民医院接受放射治疗的宫颈癌患者30例,将其作为对象展开临床分析与探究。采用Pinnacle放射治疗计划系统,分别进行VMAT人工计划与自动计划,比较两种计划靶区的D95、Dmean、均匀性指数(HI)、适形度指数(CI)、危及器官的剂量参数。结果:人工计划与自动计划在D95的比较差异无统计意义(P>0.05);人工计划与自动计划在靶区Dmean、HI、CI的比较差异显著(P<0.05)。人工计划与自动计划在膀胱、骨、小肠、直肠、右侧股骨头及左侧股骨头的危及器官剂量体积比较,差异有显著意义(P<0.05)。结论:VMAT自动计划与VMAT人工计划比较,自动计划的计划质量较高,可提高剂量参数合理性,应用Pinnacle放射治疗计划系统自动计划的宫颈癌术后VMAT计划,临床可行性较高,可将VMAT自动计划应用于临床宫颈癌术后放疗中。
Abstract:
Abstract: Objective To observe and compare the dose parameters between automatic planning and manual planning in volumetric modulated arc therapy (VMAT) for patients with cervical cancer after surgery, and to study the feasibility of automatic planning in postoperative radiotherapy of cervical cancer. Methods Thirty patients with cervical cancer who received radiotherapy in Chenzhou No.1 Peoples Hospital from November 2018 to November 2019 were enrolled for clinical analysis and exploration. Pinnacle treatment planning system was used for manual and automatic VMAT planning. The D95, Dmean, homogeneity index, conformity index of target areas and the dose parameters of organs-at-risk were compared between two plans. Results There were significant differences in the Dmean, homogeneity index and conformity index of target areas between manual planning and automatic planning (P<0.05), but not in D95 (P>0.05). Moreover, there were statistical differences in the dose-volume parameters of bladder, bone, small intestine, rectum, right femoral head and left femoral head between manual planning and automatic planning (P<0.05). Conclusion Compared with manual VMAT planning, automatic VMAT planning has higher planning quality and can improve the rationality of dose distribution. The VMAT plan automatically planned by Pinnacle treatment planning system which has higher clinical feasibility can be applied to the postoperative radiotherapy of cervical cancer.

相似文献/References:

[1]戴相昆,杨丰蔚,杜 镭,等.等效均匀剂量优化法在宫颈癌调强计划中的应用[J].中国医学物理学杂志,2015,32(02):290.[doi:10.3969/j.issn.1005-202X.2015.02.033]
[2]刘 浩,王 新,李公平,等.宫颈癌放疗高危临床靶区变化及其对累计吸收剂量的影响[J].中国医学物理学杂志,2015,32(03):379.[doi:10.3969/j.issn.1005-202X.2015.03.017]
[3]孙晓欢,周咏春,谭丽娜,等.容积旋转调强与固定野调强在宫颈癌术后放疗中的剂量学比较[J].中国医学物理学杂志,2014,31(01):4604.[doi:10.3969/j.issn.1005-202X.2014.01.003]
[4]刘 浩,王 新,李公平,等.用二维电离室矩阵验证宫颈癌腔内放疗剂量分布[J].中国医学物理学杂志,2014,31(04):4988.[doi:10.3969/j.issn.1005-202X.2014.04.004]
[5]余 辉,张书旭.宫颈癌后装治疗剂量的调强优化方法[J].中国医学物理学杂志,2014,31(05):5114.[doi:10.3969/j.issn.1005-202X.2014.05.004]
[6]查元梓,张松方,屠永清,等.子野权重优化对CMS XiO宫颈癌调强计划的影响[J].中国医学物理学杂志,2013,30(01):3866.[doi:10.3969/j.issn.1005-202X.2013.01.007]
[7]张富利,刘清智,张伟超,等.宫颈癌术后盆腔螺旋断层调强放疗两种计划设计方法的剂量学分析[J].中国医学物理学杂志,2013,30(04):4229.[doi:10.3969/j.issn.1005-202X.2013.04.003]
[8]王佳浩,赖建军,唐荣军,等.结合EPID与EUD方法确定宫颈癌病例靶区最佳生物外放边界的研究[J].中国医学物理学杂志,2013,30(05):4378.[doi:10.3969/j.issn.1005-202X.2013.05.009]
[9]张富利,刘清智,王雅棣,等.基于配置不同类型MLC叶片加速器的宫颈癌术后调强放疗计划评估[J].中国医学物理学杂志,2013,30(05):4383.[doi:10.3969/j.issn.1005-202X.2013.05.010]
[10]刘致滨,王占宇,龙雨松.两种优化技术在宫颈癌术后IMRT计划中的比较[J].中国医学物理学杂志,2015,32(04):534.[doi:10.3969/j.issn.1005-202X.2015.04.018]
 [J].Chinese Journal of Medical Physics,2015,32(8):534.[doi:10.3969/j.issn.1005-202X.2015.04.018]
[11]黄仕雄,杨松华,王亮,等.基于预测剂量引导的宫颈癌自动计划研究[J].中国医学物理学杂志,2020,37(9):1101.[doi:10.3969/j.issn.1005-202X.2020.09.004]
 HUANG Shixiong,YANG Songhua,WANG Liang,et al.Automatic planning of radiotherapy for cervical carcinoma based on dose prediction[J].Chinese Journal of Medical Physics,2020,37(8):1101.[doi:10.3969/j.issn.1005-202X.2020.09.004]

备注/Memo

备注/Memo:
【收稿日期】2020-01-17 【基金项目】广西壮族自治区卫生和计划生育委员会科研课题(Z20170499) 【作者简介】吴建篪,硕士,副主任医师,研究方向:妇科肿瘤,E-mail:c240043xy@163.com 【通信作者】邓婷,硕士,副主任医师,研究方向:妇科肿瘤,E-mail:ee8011013@qq.com
更新日期/Last Update: 2020-08-27