[1]倪晓雷,陈榕钦,柏朋刚,等. 图像引导下宫颈癌容积旋转调强放疗中膀胱和直肠实际受照剂量评估[J].中国医学物理学杂志,2019,36(2):142-145.[doi:DOI:10.3969/j.issn.1005-202X.2019.02.004]
 NI Xiaolei,CHEN Rongqin,BAI Penggang,et al. Evaluation of actual doses to bladder and rectum during image-guided volumetric modulated arc therapy for cervical cancer[J].Chinese Journal of Medical Physics,2019,36(2):142-145.[doi:DOI:10.3969/j.issn.1005-202X.2019.02.004]
点击复制

 图像引导下宫颈癌容积旋转调强放疗中膀胱和直肠实际受照剂量评估()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
36卷
期数:
2019年第2期
页码:
142-145
栏目:
医学放射物理
出版日期:
2019-02-25

文章信息/Info

Title:
 Evaluation of actual doses to bladder and rectum during image-guided volumetric modulated arc therapy for cervical cancer
文章编号:
1005-202X(2019)02-0142-04
作者:
 倪晓雷1陈榕钦2柏朋刚2陈文娟2翁星3林秀容2李奇欣2戴艺涛2陈开强2陈济鸿2张玮婷1
 1.福建医科大学附属龙岩市第一医院,福建 龙岩 364000; 2.福建医科大学附属福建省肿瘤医院, 福建 福州 350014; 3.南华大学核科学技术学院, 湖南 衡阳 421001
Author(s):
 NI Xiaolei1 CHEN Rongqin2 BAI Penggang2 CHEN Wenjuan2 WENG Xing3 LIN Xiurong2 LI Qixin2 DAI Yitao2 CHEN Kaiqiang2 CHEN Jihong2 ZHANG Weiting
 1. Longyan First Hospital, Fujian Medical University, Longyan 364000, China; 2. Fujian Tumor Hospital, Fujian Medical University, Fuzhou 350014, China; 3. School of Nuclear Science and Technology, University of South China, Hengyang 421001, China
关键词:
宫颈癌锥形束CT图像引导技术膀胱直肠平移摆位误差剂量变化
Keywords:
 Keywords: cervical cancer cone beam computed tomography image-guided radiotherapy bladder rectum translational setup error dosimetric change
分类号:
R811.1
DOI:
DOI:10.3969/j.issn.1005-202X.2019.02.004
文献标志码:
A
摘要:
 目的:研究宫颈癌容积旋转调强放疗过程中,利用图像引导技术评估膀胱与直肠因平移摆位误差因素对受照剂量的影响。 方法:入组2017年2~4月的25例行容积旋转调强放疗的宫颈癌病人。在计划CT图像和首次摆位的锥形束CT(CBCT)图像中勾画出膀胱和直肠。然后根据首次摆位误差,对膀胱和直肠在前后、左右、头脚方向上进行相应的平移。分别比较计划设计与加入平移摆位误差下的膀胱和直肠剂量差异,并用配对t检验分析差异。 结果:在计划CT与CBCT图像上勾画出的直肠体积为(33.0±16.0)和(21.8±16.5) cm3,膀胱体积为(387.1±222.3)和(227.8±107.3) cm3。在计划CT图像与考虑平移摆位误差的CBCT图像上,直肠的V50为(17.27±13.42)%和(23.9±26.58)%,膀胱的V50为(33.59±12.2)%和(44.27±22.61)%,直肠的最大剂量为(5 324±383)和(5 370±441) cGy,膀胱的最大剂量为(5 547±365)和(5 513±328) cGy。直肠和膀胱的V50均有统计学意义(t=-3.60, P<0.01;t=-2.98, P<0.01),直肠和膀胱的最大剂量均无统计学意义(t=-1.18, P=0.20;t=0.66, P=0.51)。 结论:宫颈癌放射治疗中,膀胱和直肠在计划CT和首次治疗时的体积与剂量均有较大差异,故应该多次采集图像来评估剂量分布,才能准确评价放射治疗的真正疗效。
Abstract:
 Abstract: Objective To evaluate the effects of translational setup errors on the doses to bladder and rectum during image-guided volumetric modulated arc therapy for cervical cancer. Methods Twenty-five patients receiving volumetric modulated arc therapy for cervical cancer from February 2017 to April 2017 were enrolled in this study. Bladder and rectum were delineated on the planning computed tomography (CT) images and the cone beam CT (CBCT) images obtained in the first treatment fraction. Then, bladder and rectum were shifted in the anterior-posterior, left-right, and superior-inferior directions according to the first setup errors. The planned dose of bladder and rectum were compared by those data obtained with CBCT images considering setup errors, and the dosimetric differences were compared with paired t-test. Results The rectum volumes delineated on the planning CT and CBCT images were (33.0±16.0) cm3 and (21.8±16.5) cm3, respectively, and the bladder volumes were (387.1±222.3) and (227.8±107.3) cm3, respectively. The V50 of rectum based on the planning CT and CBCT images was (17.27±13.42) % and (23.9±26.58) %, respectively; and the V50 of bladder was (33.59±12.2) % and (44.27±22.61) %, respectively, with statistical differences (t=-3.60, P<0.01; t=-2.98,P<0.01). The maximum dose of rectum based on the planning CT and CBCT images was (5 324±383) and (5 370±441) cGy, respectively; and the maximum dose of bladder was (5 547±365) and (5 513±328) cGy, respectively, with no statistical differences (t=-1.18, P=0.20; t=0.66, P=0.51). Conclusion During the radiotherapy course for cervical cancer, the volumes and doses of bladder and rectum in planning CT are significantly different from those in the first treatment fraction. CT images should be obtained for multiple fractions to evaluate the dose distribution and further assess the benefits of radiotherapy.

相似文献/References:

[1]张俊俊,杨 振,柏朋刚,等.运动模体中靶区长度与锥形束CT扫描速度的相关性[J].中国医学物理学杂志,2015,32(02):259.[doi:10.3969/j.issn.1005-202X.2015.02.025]
[2]戴相昆,杨丰蔚,杜 镭,等.等效均匀剂量优化法在宫颈癌调强计划中的应用[J].中国医学物理学杂志,2015,32(02):290.[doi:10.3969/j.issn.1005-202X.2015.02.033]
[3]张一戈,邱小平,陈维军,等.基于图像引导技术对头颈部肿瘤临床摆位误差的剂量学影响[J].中国医学物理学杂志,2015,32(01):25.[doi:10.3969/j.issn.1005-202X.2015.01.007]
[4]刘 浩,王 新,李公平,等.宫颈癌放疗高危临床靶区变化及其对累计吸收剂量的影响[J].中国医学物理学杂志,2015,32(03):379.[doi:10.3969/j.issn.1005-202X.2015.03.017]
[5]孙晓欢,周咏春,谭丽娜,等.容积旋转调强与固定野调强在宫颈癌术后放疗中的剂量学比较[J].中国医学物理学杂志,2014,31(01):4604.[doi:10.3969/j.issn.1005-202X.2014.01.003]
[6]刘 浩,王 新,李公平,等.用二维电离室矩阵验证宫颈癌腔内放疗剂量分布[J].中国医学物理学杂志,2014,31(04):4988.[doi:10.3969/j.issn.1005-202X.2014.04.004]
[7]李 毅,李文荣,苏 进,等.基于CBCT非小细胞肺癌外放边界研究[J].中国医学物理学杂志,2014,31(04):5006.[doi:10.3969/j.issn.1005-202X.2014.04.008]
[8]翁邓胡,王 建,尹中明,等.基于锥形束CT研究肺癌图像引导放疗的内靶区外放边界值[J].中国医学物理学杂志,2014,31(04):5012.[doi:10.3969/j.issn.1005-202X.2014.04.009]
[9]余 辉,张书旭.宫颈癌后装治疗剂量的调强优化方法[J].中国医学物理学杂志,2014,31(05):5114.[doi:10.3969/j.issn.1005-202X.2014.05.004]
[10]查元梓,吴晔明,陆冬青,等.应用锥形束CT研究儿童神经母细胞瘤放射治疗的摆位误差[J].中国医学物理学杂志,2014,31(05):5128.[doi:10.3969/j.issn.1005-202X.2014.05.007]
[11]闵蒙真,丘敏敏,钟嘉健,等. 宫颈癌调强放疗中膀胱体积改变及其剂量学变化测量[J].中国医学物理学杂志,2019,36(4):402.[doi:DOI:10.3969/j.issn.1005-202X.2019.04.007]
 MIN Mengzhen,QIU Minmin,ZHONG Jiajian,et al. Measurement of changes in bladder volume and dosimetric variations in intensity-modulated radiotherapy for cervical cancer[J].Chinese Journal of Medical Physics,2019,36(2):402.[doi:DOI:10.3969/j.issn.1005-202X.2019.04.007]
[12]刘巍巍,王美娇,杨敬贤,等. 热塑膜联合发泡胶固定技术在宫颈癌放疗中的应用价值[J].中国医学物理学杂志,2019,36(6):636.[doi:DOI:10.3969/j.issn.1005-202X.2019.06.004]
 LIU Weiwei,WANG Meijiao,YANG Jingxian,et al. Application value of thermoplastic film combined with styrofoam fixation technology in radiotherapy for cervical cancer[J].Chinese Journal of Medical Physics,2019,36(2):636.[doi:DOI:10.3969/j.issn.1005-202X.2019.06.004]
[13]梁黎,李勇.体质量指数对锥形束CT引导的宫颈癌放疗分次间摆位误差的影响[J].中国医学物理学杂志,2023,40(2):144.[doi:DOI:10.3969/j.issn.1005-202X.2023.02.003]
 LIANG Li,LI Yong.Effect of body mass index on inter-fractional setup errors in cone beam CT-guided radiotherapy of cervical cancer[J].Chinese Journal of Medical Physics,2023,40(2):144.[doi:DOI:10.3969/j.issn.1005-202X.2023.02.003]

备注/Memo

备注/Memo:
 【收稿日期】2018-09-21
【基金项目】福建省自然科学基金(2015J01366);福建省医学创新课题(2017-CX-8);福建省卫生计生中青年骨干人才培养项目(2017-ZQN-15)
【作者简介】倪晓雷,硕士,副主任医师,主要研究方向:恶性肿瘤放射治疗,E-mail: nixiaolei2005@126.com
【通信作者】陈文娟,E-mail: chenwj92@126.com
更新日期/Last Update: 2019-02-26