[1]刘娟,李双双,高山宝,等. 宫颈癌螺旋断层放疗与静态调强技术的剂量学比较[J].中国医学物理学杂志,2019,36(1):23-28.[doi:DOI:10.3969/j.issn.1005-202X.2019.01.005]
 LIU Juan,LI Shuangshuang,GAO Shanbao,et al. Dosimetric comparison of helical tomotherapy versus fixed-field intensity-modulated radiotherapy for cervical cancer[J].Chinese Journal of Medical Physics,2019,36(1):23-28.[doi:DOI:10.3969/j.issn.1005-202X.2019.01.005]
点击复制

 宫颈癌螺旋断层放疗与静态调强技术的剂量学比较()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
36卷
期数:
2019年第1期
页码:
23-28
栏目:
医学放射物理
出版日期:
2019-01-25

文章信息/Info

Title:
 Dosimetric comparison of helical tomotherapy versus fixed-field intensity-modulated radiotherapy for cervical cancer
文章编号:
1005-202X(2019)01-0023-06
作者:
 刘娟1李双双1高山宝1闫婧1侯震2朱丽晶1
 1.南京大学医学院附属鼓楼医院肿瘤中心, 江苏 南京 210000; 2.东南大学生物科学与医学工程学院生物电子学国家重点实验室、医学电子学实验室, 江苏 南京 210096
Author(s):
 LIU Juan1 LI Shuangshuang1 GAO Shanbao1 YAN Jing1 HOU Zhen2 ZHU Lijing1
 1. Cancer Center, Nanjing Drum Tower Hospital Affiliated to Medical School of Nanjing University, Nanjing 210000, China;
2. Laboratory for Medical Electronics, State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
关键词:
宫颈癌放射治疗螺旋断层放射治疗调强放射治疗剂量学
Keywords:
 Keywords: cervical cancer radiotherapy helical tomotherapy intensity-modulated radiotherapy dosimetry
分类号:
R811.1
DOI:
DOI:10.3969/j.issn.1005-202X.2019.01.005
文献标志码:
A
摘要:
 目的:比较宫颈癌盆腔照射螺旋断层放射治疗(Helical Tomotherapy, HT)计划与七野-静态调强放疗(7F-IMRT)计划的靶区和危及器官的剂量学差异。 方法:选取2015年3月~2017年10月行HT治疗的25例宫颈癌患者,均采用俯卧位,憋尿状态。分别进行HT和7F-IMRT两种计划设计,比较两种计划模式之间靶区和危及器官之间的剂量学参数及机器输出跳数。 结果:(1)计划靶区(PTV):HT组CI和HI均优于7F-IMRT组,具有统计学差异(0.898±0.017 vs 0.834±0.013, P<0.001;0.062±0.012 vs 0.109±0.019, P<0.001);HT组PTV的D1、D2均低于7F-IMRT组(P<0.001),Dmean、D98、D95均较7F-IMRT组高(P=0.048, P<0.001, P=0.015)。(2)对于正常组织,HT组小肠、结肠、直肠和膀胱的Dmax、Dmean、V30、V40以及直肠V50均显著低于7F-IMRT组(P<0.001, P<0.001, P<0.001, P=0.001, P=0.006),其余V50略低,无统计学差异(P=0.130);HT组双侧股骨头V25、D5、Dmean、Dmax也显著低于7F-IMRT组(P<0.001);但是,HT组的机器输出量明显高于7F-IMRT组。 结论:HT计划在适形度、均匀性及周围正常组织保护上显著优于7F-IMRT计划,在充分保证靶区剂量的同时又不增加患者放疗毒副反应;但其机器输出量高于7F-IMRT计划,对射束的利用率不高。在后续治疗实施过程中,HT系统作为影像引导放射治疗技术,确保每次治疗过程中的精准度,值得临床应用。
Abstract:
 Abstract: Objective To compare the dosimetric differences of target areas and organs-at-risk between helical tomotherapy (HT) and 7-field intensity-modulated radiotherapy (7F-IMRT) for cervical cancer. Methods Twenty-five patients with cervical cancer who underwent helical tomography between March 2015 and October 2017 were enrolled in this study. All enrolled patients were treated in prone position, with a full bladder. Both HT planning and 7F-IMRT planning were carried out for each patient. The dosimetry parameters of target areas and organs-at-risk, and monitor units (MU) were compared between two planning modes. Results HT plan was better than 7F-IMRT plan in conformity index and homogeneity index [0.898±0.017 vs 0.834±0.013, P<0.001; 0.062±0.012 vs 0.109±0.019, P<0.001]. The D1 and D2 of planning target volume in HT group were lower than those in 7F-IMRT group (all P<0.001) , while Dmean, D98 and D95 in HT group were higher than those in 7F-IMRT group (P=0.048, P<0.001, P=0.015). The Dmax, Dmean, V30 and V40 of small intestine, colon, rectum and bladder and the V50 of rectum were significant lower (P<0.001, P<0.001, P<0.001, P=0.001, P=0.006), and the V50 of the other organs-at-risk was slightly lower (P=0.130) in HT group as compared with 7F-IMRT group. Moreover, the V25, D5, Dmean and Dmax of femoral heads in HT group were significantly lower than those in 7F-IMRT group (all P<0.001). However, compared with 7F-IMRT group, HT group had a much higher MU. Conclusion HT plan which ensures the target dose without increasing the radiotherapy toxicity is superior to 7F-IMRT plan in conformity index, homogeneity index and organs-at-risk sparing. However, the MU of HT plan is higher than that of 7F-IMRT plan, which indicates a lower utilization rate of beams in HT plan. As an image-guided radiotherapy technology, HT system is worthy of application for it can ensure the accuracy of each radiotherapy.

相似文献/References:

[1]武 杰,袁杭英,欧阳蓓蕾.内旋式放射治疗用面罩固定装置的设计[J].中国医学物理学杂志,2015,32(02):265.[doi:10.3969/j.issn.1005-202X.2015.02.027]
[2]戴相昆,杨丰蔚,杜 镭,等.等效均匀剂量优化法在宫颈癌调强计划中的应用[J].中国医学物理学杂志,2015,32(02):290.[doi:10.3969/j.issn.1005-202X.2015.02.033]
[3]司 森,吴鑫全,包尚联,等.基于GPU的蒙特卡洛放疗剂量模拟[J].中国医学物理学杂志,2015,32(01):1.[doi:10.3969/j.issn.1005-202X.2015.01.001]
[4]王 文,程梦云,杨 琪,等.基于MCNP源子程序的放射治疗剂量计算验证方法[J].中国医学物理学杂志,2015,32(01):13.[doi:10.3969/j.issn.1005-202X.2015.01.004]
[5]张一戈,邱小平,陈维军,等.基于图像引导技术对头颈部肿瘤临床摆位误差的剂量学影响[J].中国医学物理学杂志,2015,32(01):25.[doi:10.3969/j.issn.1005-202X.2015.01.007]
[6]孟慧鹏,孙小喆,王 昊,等.胸部偏后背肿瘤RapidArc采用仰卧位设计治疗计划的可行性分析[J].中国医学物理学杂志,2015,32(01):31.[doi:10.3969/j.issn.1005-202X.2015.01.008]
[7]刘 浩,王 新,李公平,等.宫颈癌放疗高危临床靶区变化及其对累计吸收剂量的影响[J].中国医学物理学杂志,2015,32(03):379.[doi:10.3969/j.issn.1005-202X.2015.03.017]
[8]庞皓文,孙小扬.基于快速自由形变的弹性配准算法在放疗CT中的应用[J].中国医学物理学杂志,2015,32(03):404.[doi:10.3969/j.issn.1005-202X.2015.03.023]
[9]孙晓欢,周咏春,谭丽娜,等.容积旋转调强与固定野调强在宫颈癌术后放疗中的剂量学比较[J].中国医学物理学杂志,2014,31(01):4604.[doi:10.3969/j.issn.1005-202X.2014.01.003]
[10]贾卫娟,周一兵,谭维维,等.利用模拟机及挡铅托架进行放疗前的治疗模拟[J].中国医学物理学杂志,2014,31(01):4622.[doi:10.3969/j.issn.1005-202X.2014.01.007]
[11]王金媛,徐寿平,杨微,等.算法和匹配数目对宫颈癌危及器官自动勾画的影响[J].中国医学物理学杂志,2019,36(11):1243.[doi:DOI:10.3969/j.issn.1005-202X.2019.11.001]
 WANG Jinyuan,XU Shouping,YANG Wei,et al.Effects of algorithm and matching number on the auto-segmentation of organs-at-risk in patients with cervical cancer[J].Chinese Journal of Medical Physics,2019,36(1):1243.[doi:DOI:10.3969/j.issn.1005-202X.2019.11.001]
[12]黄洋洋,李家兵,田玉龙,等.宫颈癌直线加速器放疗时保卵巢对靶区和危及器官的影响[J].中国医学物理学杂志,2020,37(9):1115.[doi:10.3969/j.issn.1005-202X.2020.09.007]
 HUANG Yangyang,LI Jiabing,TIAN Yulong,et al.Effects of ovaries sparing on planning target volume and organs-at-risk during linearaccelerator radiotherapy for cervical cancer[J].Chinese Journal of Medical Physics,2020,37(1):1115.[doi:10.3969/j.issn.1005-202X.2020.09.007]
[13]梁黎,李勇.体质量指数对锥形束CT引导的宫颈癌放疗分次间摆位误差的影响[J].中国医学物理学杂志,2023,40(2):144.[doi:DOI:10.3969/j.issn.1005-202X.2023.02.003]
 LIANG Li,LI Yong.Effect of body mass index on inter-fractional setup errors in cone beam CT-guided radiotherapy of cervical cancer[J].Chinese Journal of Medical Physics,2023,40(1):144.[doi:DOI:10.3969/j.issn.1005-202X.2023.02.003]
[14]许晨迪,姜晓勃,王亚娟,等.基于扇形束CT研究不同固定体位下宫颈癌术后放疗中膀胱体积改变对膀胱和小肠受照剂量的影响[J].中国医学物理学杂志,2023,40(5):529.[doi:DOI:10.3969/j.issn.1005-202X.2023.05.001]
 XU Chendi,JIANG Xiaobo,WANG Yajuan,et al.Effects of bladder volume variation on doses to bladder and small bowel in postoperative radiotherapy for cervical cancer in different patient positioning: an analysis based on FBCT[J].Chinese Journal of Medical Physics,2023,40(1):529.[doi:DOI:10.3969/j.issn.1005-202X.2023.05.001]

备注/Memo

备注/Memo:
 【收稿日期】2018-08-11
【基金项目】江苏省自然科学基金青年项目(BK20150102)
【作者简介】刘娟,硕士,主管技师,研究方向:医学物理和肿瘤放射治疗,E-mail: liuuar0813@163.com
【通信作者】朱丽晶,博士,副主任医师,副教授,研究方向:妇科肿瘤的综合治疗,E-mail: zhulj@hotmail.com
更新日期/Last Update: 2019-01-24