[1]刘珩,王雁南,那飞扬,等.低管电压联合ASiR-V算法“一站式”心脑血管CTA扫描模式的应用价值[J].中国医学物理学杂志,2023,40(2):176-181.[doi:DOI:10.3969/j.issn.1005-202X.2023.02.008]
 LIU Heng,WANG Yannan,NA Feiyang,et al.Clinical significance of one-stop cardio-cerebrovascular CTA scanning mode of low-tube voltage combined with ASiR-V algorithm[J].Chinese Journal of Medical Physics,2023,40(2):176-181.[doi:DOI:10.3969/j.issn.1005-202X.2023.02.008]
点击复制

低管电压联合ASiR-V算法“一站式”心脑血管CTA扫描模式的应用价值()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
40卷
期数:
2023年第2期
页码:
176-181
栏目:
医学影像物理
出版日期:
2023-03-03

文章信息/Info

Title:
Clinical significance of one-stop cardio-cerebrovascular CTA scanning mode of low-tube voltage combined with ASiR-V algorithm
文章编号:
1005-202X(2023)02-0176-06
作者:
刘珩1王雁南23那飞扬4刘显旺23刘建莉23张小卫15
1.兰州大学第二临床医学院, 甘肃 兰州 730000; 2.兰州大学第二医院放射科, 甘肃 兰州 730000; 3.甘肃省医学影像重点实验室, 甘肃 兰州730000; 4.甘肃省妇幼保健院过敏反应科, 甘肃 兰州 730000; 5.兰州大学第二医院心内科, 甘肃 兰州 730000
Author(s):
LIU Heng1 WANG Yannan2 3 NA Feiyang4 LIU Xianwang2 3 LIU Jianli2 3 ZHANG Xiaowei1 5
1. The Second Clinical Medical College of Lanzhou University, Lanzhou 730000, China 2. Department of Radiology, Lanzhou University Second Hospital, Lanzhou 730000, China 3. Key Laboratory of Medical Imaging in Gansu Province, Lanzhou 730000, China 4. Allergy Department, Gansu Provincial Maternity and Child-care Hospital, Lanzhou 730000, China 5. Department of Cardiology, Lanzhou University Second Hospital, Lanzhou 730000, China
关键词:
动脉粥样硬化低剂量一站式扫描冠状动脉头颈CT血管造影
Keywords:
Keywords: atherosclerosis low dose one-stop scanning coronary artery head and neck CT angiography
分类号:
R318;R816.2
DOI:
DOI:10.3969/j.issn.1005-202X.2023.02.008
文献标志码:
A
摘要:
目的:探讨低管电压联合ASiR-V算法“一站式”心脑血管CTA扫描模式在动脉粥样硬化导致的心脑血管疾病评估中的临床应用价值。方法:回顾性分析需要进行心脑血管疾病筛查扫描的120例患者。依据扫描方式不同,分为3组,每组40人。A组为低剂量一站式”心脑血管CTA扫描模式组(80 kV,管电流智能调控,前置40%ASIR-V,后置50%ASiR-V),B组为常规剂量冠状动脉CTA扫描组(100 kV,550 mA),C组为常规剂量头颈动脉CTA扫描组(100 kV, 500 mA)。对比3组扫描模式的辐射剂量和对比剂用量,同时将3组图像进行主观评价和客观评价。结果:低管电压联合ASiR-V算法“一站式”心脑血管CTA扫描模式有效辐射剂量为(1.36±0.66) mSv,B组的辐射剂量为(2.31±0.75) mSv,C组的辐射剂量为(1.12±0.04) mSv,A组辐射剂量与B组+C组辐射剂量之和差异有统计学意义(P<0.05),A组与B组的LAD近端、LCX近端、RCA近端的CT值差异均无统计学意义(P>0.05),A组与B组的SD、CNR值差异无统计学意义(P>0.05),A组与B组CTA图像质量主观评分差异无统计学意义(P>0.05);A组与C组的CT值差异均无统计学意义(P>0.05),A组与C组的SD、CNR值差异有统计学意义(P<0.05),A组与C组图像质量主观评分差异无统计学意义(P>0.05)。结论:低剂量“一站式”头颈冠脉血管成像扫描模式的图像质量能满足临床需求,能全面评估动脉粥样硬化导致的心脑血管疾病。
Abstract:
Abstract: Objective To investigate the value of one-stop cardio-cerebrovascular CT angiography (CTA) scanning mode of low-tube voltage combined with ASiR-V algorithm in the evaluation of cardiovascular and cerebrovascular diseases caused by atherosclerosis. Methods A retrospective analysis was conducted on 120 patients who needed screening for cardiovascular and cerebrovascular diseases. According to different scanning methods, the patients were divided into 3 groups, with 40 patients in each group. Low-dose one-stop cardio-cerebrovascular CTA scanning mode (80 kV, automatic milliamperage, 40%ASIR-V preposition, 50%ASIR-V postposition) was adopted in group A, conventional-dose coronary CTA scanning mode (100 kV, 550 mA) in group B, and conventional-dose head and neck CTA scanning mode (100 kV, 500 mA) in group C. The radiation dose and contrast agent dosage were compared among 3 groups of scanning modes, and the obtained images were evaluated subjectively and objectively. Results The effective radiation dose of one-stop cardio-cerebrovascular CTA scanning mode of low tube voltage combined with ASiR-V algorithm was (1.36±0.66) mSv, and the radiation dose was (2.31±0.75) mSv in group B and (1.12±0.04) mSv in group C. The effective radiation dose in group A was significantly lower than the sum of group B and group C (P<0.05). There was no statistical significance between group A and group B in the CT number of LAD proximal end, LCX proximal end and RCA proximal end, SD, CNR, and the subjective score of CTA image quality (P>0.05). The CT number and subjective score of image quality in group A were close to those in group C (P>0.05), but there were significant differences in SD and CNR between group A and group C (P<0.05). Conclusion The low-dose one-stop head and neck coronary angiography scanning mode ensures that the image quality meets the requirements, and it can be used to comprehensively evaluate the cardiovascular and cerebro vascular diseases caused by atherosclerosis.

相似文献/References:

[1]章德发,刘 莹,史皓良,等.T型分叉管内牛顿与非牛顿血流特性对比分析[J].中国医学物理学杂志,2015,32(02):198.[doi:10.3969/j.issn.1005-202X.2015.02.010]
[2]黄小伟,张艳玲,魏夏平,等.基于斑块超声图像灰度分布的双峰Gamma模型评估斑块风险[J].中国医学物理学杂志,2015,32(02):272.[doi:10.3969/j.issn.1005-202X.2015.02.029]
[3]沈晓波.低剂量CT技术发展及其临床应用[J].中国医学物理学杂志,2016,33(3):238.[doi:10.3969/j.issn.1005-202X.2016.03.004]
 [J].Chinese Journal of Medical Physics,2016,33(2):238.[doi:10.3969/j.issn.1005-202X.2016.03.004]
[4]李大鹏,田秀梅.基于图像线性融合的低剂量CT成像[J].中国医学物理学杂志,2016,33(8):814.[doi:10.3969/j.issn.1005-202X.2016.08.012]
 [J].Chinese Journal of Medical Physics,2016,33(2):814.[doi:10.3969/j.issn.1005-202X.2016.08.012]
[5]胡安宁,朱景雨,施健. 一种全新的基于EOS影像的骨放射评价标准[J].中国医学物理学杂志,2017,34(4):371.[doi:DOI:10.3969/j.issn.1005-202X.2017.04.010]
[6]楚轶,冯品,张薇,等. 稳恒磁场刺激对糖尿病动脉粥样硬化大鼠血清和主动脉中VEGF、TGF-β1、TNF-α和IL-6表达的影响[J].中国医学物理学杂志,2017,34(10):1045.[doi:DOI:10.3969/j.issn.1005-202X.2017.10.016]
 [J].Chinese Journal of Medical Physics,2017,34(2):1045.[doi:DOI:10.3969/j.issn.1005-202X.2017.10.016]
[7]郭广威,莫贤海,陈炯,等. 低剂量与标准剂量CT对慢性鼻窦炎手术高风险患者图像质量和辐射剂量的影响[J].中国医学物理学杂志,2017,34(11):1137.[doi:DOI:10.3969/j.issn.1005-202X.2017.11.011]
 GUO Guangwei,MO Xianhai,CHEN Jiong,et al. Evaluation of low-dose versus standard-dose CT examination in surgical high-risk patients with chronic rhinosinusitis[J].Chinese Journal of Medical Physics,2017,34(2):1137.[doi:DOI:10.3969/j.issn.1005-202X.2017.11.011]
[8]罗川. 颈动脉多普勒超声对慢性肾病患者动脉粥样硬化程度及血流动力学的诊断价值[J].中国医学物理学杂志,2019,36(4):479.[doi:DOI:10.3969/j.issn.1005-202X.2019.04.021]
 LUO Chuan. Diagnostic value of carotid Doppler ultrasound for atherosclerosis and hemodynamic status in patients with chronic renal diseases[J].Chinese Journal of Medical Physics,2019,36(2):479.[doi:DOI:10.3969/j.issn.1005-202X.2019.04.021]
[9]王雁南,周俊林,刘建莉,等.多排螺旋CT低剂量扫描高分辨率重建在新型冠状病毒肺炎筛查中的应用[J].中国医学物理学杂志,2021,38(4):456.[doi:DOI:10.3969/j.issn.1005-202X.2021.04.012]
 WANG Yannan,,et al.Application of low-dose multidetector CT scan and high-resolution reconstruction in COVID-19 pneumonia screening[J].Chinese Journal of Medical Physics,2021,38(2):456.[doi:DOI:10.3969/j.issn.1005-202X.2021.04.012]
[10]谢孟臻,吴斌,刘于宝,等.超低对比剂剂量和流率在头颈部CT血管造影中的应用[J].中国医学物理学杂志,2022,39(9):1128.[doi:DOI:10.3969/j.issn.1005-202X.2022.09.012]
 XIE Mengzhen,WU Bin,LIU Yubao,et al.Application of ultra-low dose and flow-rate contrast injection protocol in head and neck CT angiography[J].Chinese Journal of Medical Physics,2022,39(2):1128.[doi:DOI:10.3969/j.issn.1005-202X.2022.09.012]

备注/Memo

备注/Memo:
【收稿日期】2022-10-26 【基金项目】国家自然科学基金(82060080);甘肃省自然科学基金(22JR5RA996) 【作者简介】刘珩,住院医师,研究方向:神经影像技术,E-mail: 2177726547@qq.com 【通信作者】张小卫,主任医师,E-mail: xwzhang@lzu.edu.cn
更新日期/Last Update: 2023-03-03