Title:
An analysis of influence of different equipment and different scanning parameters on reproducibility of radiomics features
文章编号:
1005-202X(2021)01-0061-04
作者:
张白霖戴振晖朱琳杨耕朱远湖招什武蔡春雅李飞王学涛
广州中医药大学第二附属医院放疗中心, 广东 广州 510006
Author(s):
ZHANG Bailin DAI Zhenhui ZHU Lin YANG Geng ZHU Yuanhu ZHAO Shiwu LI Fei CAI Chunya WANG Xuetao
Radiotherapy Center, the Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510006, China
关键词:
影像组学可再现性计算机断层扫描扫描参数
Keywords:
Keywords: radiomics reproducibility computed tomography scanning parameter
分类号:
R318
DOI:
DOI:10.3969/j.issn.1005-202X.2021.01.011
文献标志码:
A
摘要:
目的:分析影像组学特征在不同设备不同扫描参数中的可再现性。方法:在3台CT设备上设置不同扫描参数:重建层厚(1、3、5 mm)、重建核函数(和CT设备有关)、曝光时间(50、100、300 mAs),扫描2种模体,提取影像组学特征并评估特征可再现性。结果:81.6%的特征在不同层厚条件下可再现性差(变异系数CV>10%);有8.8%的特征在3台设备中均满足要求(CV<10%)。46.4%的特征在不同重建核函数条件下可再现性差;有12.1%的特征在3台设备中均满足要求(CV<10%);占总数31.7%的特征只在单一设备中达到可再现性要求。54%的特征在不同曝光时间条件下可再现性差。结论:应用影像组学建立模型研究临床问题时,应充分考虑并避免扫描参数对影像组学特征可再现性的不利影响,以获得更好的临床研究结果。
Abstract:
Abstract: Objective To analyse the reproducibility of radiomics features in different CT equipment with various scanning parameters. Methods Different scanning parameters were set on three CT machines: different reconstruction slice thickness (1, 3, 5 mm respectively), different reconstruction kernel function (related to specific CT machines), different exposure time (50, 100, 300 mAs respectively), and two kinds of phantom were scanned to extract radiomics features and evaluate their reproducibility. Results 81.6% of the features had poor reproducibility (CV>10%) under different slice thickness, and only 8.8% of the features in the three machines met the requirements (CV<10%) 46.4% of the features have poor reproducibility under different reconstruction kernel functions, and only 12.1% of the features in three machines meet the requirements (CV<10%) 31.7% of the features met the reproducibility requirements only in a single machine 54% of the features have poor reproducibility under different exposure time. Conclusion When using radiomics to establish a model to study clinical problems, the adverse effects of scanning parameters on the reproducibility of imaging histology features should be fully considered and avoided in order to obtain better clinical research results.

相似文献/References:

[1]李双双,侯震,刘娟,等.影像组学分析与建模工具综述[J].中国医学物理学杂志,2018,35(9):1043.[doi:10.3969/j.issn.1005-202X.2018.09.010]
 LI Shuangshuang,HOU Zhen,LIU Juan,et al.Review of radiomic analysis and modeling tools[J].Chinese Journal of Medical Physics,2018,35(1):1043.[doi:10.3969/j.issn.1005-202X.2018.09.010]
[2]沙雪,巩贯忠,邓红彬,等. 18F-FDG PET/CT影像组学预测非小细胞肺癌亚型的研究[J].中国医学物理学杂志,2019,36(3):311.[doi:DOI:10.3969/j.issn.1005-202X.2019.03.013]
 SHA Xue,GONG Guanzhong,DENG Hongbin,et al. 18F-FDG PET/CT radiomic features for predicting the subtypes of non-small-cell lung cancer[J].Chinese Journal of Medical Physics,2019,36(1):311.[doi:DOI:10.3969/j.issn.1005-202X.2019.03.013]
[3]李腾翔,巩贯忠,仇清涛,等. 鼻咽癌CT影像组学量化分析研究[J].中国医学物理学杂志,2019,36(5):551.[doi:DOI:10.3969/j.issn.1005-202X.2019.05.011]
 LI Tengxiang,GONG Guanzhong,QIU Qingtao,et al. Quantitative analysis of CT radiomics features of nasopharyngeal carcinoma[J].Chinese Journal of Medical Physics,2019,36(1):551.[doi:DOI:10.3969/j.issn.1005-202X.2019.05.011]
[4]周榴,董怡,夏威,等.基于超声影像组学的原发性肝细胞癌分级预测[J].中国医学物理学杂志,2020,37(1):59.[doi:DOI:10.3969/j.issn.1005-202X.2020.01.012]
 ZHOU Liu,DONG Yi,XIA Wei,et al.Prediction of grade of hepatocellular carcinoma by radiomics based on ultrasound[J].Chinese Journal of Medical Physics,2020,37(1):59.[doi:DOI:10.3969/j.issn.1005-202X.2020.01.012]
[5]刘发明,江桂华,杨宁,等.新型冠状病毒肺炎的影像组学研究[J].中国医学物理学杂志,2020,37(4):463.[doi:DOI:10.3969/j.issn.1005-202X.2020.04.012]
 LIU Faming,JIANG Guihua,YANG Ning,et al.Radiomics analysis on COVID-19[J].Chinese Journal of Medical Physics,2020,37(1):463.[doi:DOI:10.3969/j.issn.1005-202X.2020.04.012]
[6]张祥斌,戴谷宇,肖青,等.基于电子射野影像装置通量变化的影像组学特征进行眼突放射治疗摆位误差探测的初步研究[J].中国医学物理学杂志,2021,38(2):153.[doi:DOI:10.3969/j.issn.1005-202X.2021.02.005]
 ZHANG Xiangbin,DAI Guyu,XIAO Qing,et al.Preliminary study of radiomics features of EPID image in detecting setup errors in eye lens radiotherapy[J].Chinese Journal of Medical Physics,2021,38(1):153.[doi:DOI:10.3969/j.issn.1005-202X.2021.02.005]
[7]陈文韬,孙磊,谭爱斌,等.基于CT的影像组学特征同临床物理剂量特征预测肺癌放疗放射性肺炎研究[J].中国医学物理学杂志,2021,38(6):672.[doi:DOI:10.3969/j.issn.1005-202X.2021.06.003]
 CHEN Wentao,SUN Lei,et al.Prediction of radiation pneumonia in lung cancer patients by CT-based radiomics signatures and clinical physical dosimetric features[J].Chinese Journal of Medical Physics,2021,38(1):672.[doi:DOI:10.3969/j.issn.1005-202X.2021.06.003]
[8]范晓鸿,董可,杨银,等.放射性肺损伤与三维剂量分布的相关性研究[J].中国医学物理学杂志,2021,38(6):692.[doi:DOI:10.3969/j.issn.1005-202X.2021.06.007]
 FAN Xiaohong,DONG Ke,YANG Yin,et al.Correlation between radiation-induced lung injury and 3D dose distribution[J].Chinese Journal of Medical Physics,2021,38(1):692.[doi:DOI:10.3969/j.issn.1005-202X.2021.06.007]
[9]卢孔尧,黄钢,左艳.非小细胞肺癌淋巴结转移预测模型研究[J].中国医学物理学杂志,2022,39(2):182.[doi:DOI:10.3969/j.issn.1005-202X.2022.02.009]
 LU Kongyao,HUANG Gang,ZUO Yan.Prediction model for lymph node metastasis in non-small cell lung cancer[J].Chinese Journal of Medical Physics,2022,39(1):182.[doi:DOI:10.3969/j.issn.1005-202X.2022.02.009]
[10]张白霖,黄泽裕,戴振晖,等.直肠充盈对直肠壁CT影像组学特征的影响[J].中国医学物理学杂志,2022,39(2):194.[doi:DOI:10.3969/j.issn.1005-202X.2022.02.011]
 ZHANG Bailin,Huang Zeyu,DAI Zhenhui,et al.Effects of rectal filling on CT radiomics features of rectal wall[J].Chinese Journal of Medical Physics,2022,39(1):194.[doi:DOI:10.3969/j.issn.1005-202X.2022.02.011]

备注/Memo

备注/Memo:
【收稿日期】2020-04-22 【基金项目】广东省科技厅自筹经费类项目(2017ZC0165);广东省医学科学技术研究基金(A2019196);广东省医学会医学工程学分会青年委员会科研课题(2019-GDMAZD-01) 【作者简介】张白霖,工程师,研究方向:肿瘤放射物理,E-mail: 18348- 9907@qq.com 【通信作者】王学涛,主任技师,研究方向:肿瘤放射物理,E-mail: wang- xuetao0625@126.com
更新日期/Last Update: 2021-01-29