[1]黄晓宇,解琪琪,邓亚军,等. 能谱CT评估生物力学的初步研究[J].中国医学物理学杂志,2018,35(6):720-723.[doi:DOI:10.3969/j.issn.1005-202X.2018.06.018]
 HUANG Xiaoyu,XIE Qiqi,DENG Yajun,et al. Preliminary study of evaluating biomechanics with energy spectral computed tomography[J].Chinese Journal of Medical Physics,2018,35(6):720-723.[doi:DOI:10.3969/j.issn.1005-202X.2018.06.018]
点击复制

 能谱CT评估生物力学的初步研究()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
35卷
期数:
2018年第6期
页码:
720-723
栏目:
医学生物物理
出版日期:
2018-06-22

文章信息/Info

Title:
 Preliminary study of evaluating biomechanics with energy spectral computed tomography
文章编号:
1005-202X(2018)06-0720-04
作者:
 黄晓宇12解琪琪13邓亚军13赵若辰14董强4周俊林12
 1.兰州大学, 甘肃 兰州730030; 2.兰州大学第二医院放射科, 甘肃 兰州730030; 3.兰州大学第二医院骨科, 甘肃 兰州730030; 4.兰州大学第二医院神经外科, 甘肃 兰州730030
Author(s):
 HUANG Xiaoyu12 XIE Qiqi13 DENG Yajun13 ZHAO Ruochen14 DONG Qiang4 ZHOU Junlin12
 1. Lanzhou University, Lanzhou 730030, China; 2. Department of Radiology, Second Hospital of Lanzhou University, Lanzhou 730030, China; 3. Department of Orthopedics, Second Hospital of Lanzhou University, Lanzhou 730030, China; 4. Department of Neurosurgery, Second Hospital of Lanzhou University, Lanzhou 730030, China
关键词:
能谱CT骨质疏松生物力学骨强度
Keywords:
 Keywords: energy spectrum computed tomography osteoporosis biomechanics bone strength
分类号:
R445.3
DOI:
DOI:10.3969/j.issn.1005-202X.2018.06.018
文献标志码:
A
摘要:
 目的:通过分析能谱CT定量参数与生物力学的相关性,探讨能谱CT定量参数评估骨强度的价值。 方法:采用能谱CT成像扫描36个羊腰椎椎体,测定每个椎体的骨松质、骨皮质及皮质+松质的能谱CT基物质对(铁-水、钙-水、羟基磷灰石-水)密度,然后将各个椎体去除附件对应编号,行腰椎压缩实验。将能谱不同基物质对(铁-水、钙-水、羟基磷灰石-水)密度值与生物力学测得的最大载荷和最大应力进行相关性分析。 结果:能谱CT基物质对密度值与生物力学相关性分析可得,在松质+皮质时钙-水、羟基磷灰石-水与最大应力呈强相关(R2=0.508, P<0.05; R2=0.507, P<0.05),与最大载荷呈中等程度相关(R2=0.454, P<0.05; R2=0.451, P<0.05),而铁-水相关性较低;皮质、松质的3个基物质对密度值与生物力学值相关性较差。 结论:能谱CT定量参数可以用来评价骨强度。
Abstract:
 Abstract: Objective To analyze the correlations between energy spectral computed tomography (CT) quantitative parameters and biomechanics, and explore the value of energy spectral CT quantitative parameters in the assessment of bone strength. Methods Energy spectral CT scanning was performed on 36 vertebral bodies to determine the density of CT-based material pairs (iron-water, calcium-water and hydroxyl-phosphorus) in cancellous, cortex and cortico-cancellous in each vertebral body of the sheep. Then the corresponding number of each vertebral body was removed, and lumbar compression experiment was conducted. The correlations between the density values of different pairs??(iron-water, calcium-water and hydroxyapatite-water) and the maximum load and maximum stress measured by biomechanics were analyzed. Results The analysis of the correlations between density values and biomechanical properties of energy spectral CT-based materials showed that for cortico-cancellous, calcium-water and hydroxyapatite-water were strongly correlated with the maximum stress (R2=0.508, P<0.05; R2=0.507, P<0.05), and moderately correlated with the maximum load (R2=0.454, P<0.05;R2=0.451, P<0.05), while the iron-water correlation was relatively lower. The 3 CT-based material pairs of cortex and cancellous had poor correlations between density values ??and biomechanical properties. Conclusion Energy spectral CT quantitative parameters can be used to evaluate bone strength.

相似文献/References:

[1]王光笋,陈强,林桂淼,等.旋转恒定磁场对骨质疏松大鼠血清铁和铁调素的影响[J].中国医学物理学杂志,2014,31(03):4948.[doi:10.3969/j.issn.1005-202X.2014.03.023]
[2]高嵩,杜江,包尚联,等.超短回波磁共振成像与骨质量检测[J].中国医学物理学杂志,2013,30(02):4004.[doi:10.3969/j.issn.1005-202X.2013.02.010]
[3]任晓静,蔡思清,吕国荣,等. 髋部结构分析在预测髋部脆性骨折的意义[J].中国医学物理学杂志,2017,34(5):513.[doi:DOI:10.3969/j.issn.1005-202X.2017.05.016]
 [J].Chinese Journal of Medical Physics,2017,34(6):513.[doi:DOI:10.3969/j.issn.1005-202X.2017.05.016]
[4]胡志,余晓锷,康立丽,等. 基于一种体模对CT能谱技术的质量检测[J].中国医学物理学杂志,2018,35(1):54.[doi:DOI:10.3969/j.issn.1005-202X.2018.01.011]
 HU Zhi,YU Xiaoe,KANG Lili,et al. Phantom-based quality testing for spectral computed tomography technology[J].Chinese Journal of Medical Physics,2018,35(6):54.[doi:DOI:10.3969/j.issn.1005-202X.2018.01.011]
[5]李文洲,解琪琪,任恩惠,等. DXA检测糖尿病性骨质疏松大鼠骨密度的部位选择[J].中国医学物理学杂志,2018,35(7):843.[doi:DOI:10.3969/j.issn.1005-202X.2018.07.020]
 LI Wenzhou,XIE Qiqi,et al. Optimal site for DXA to detect bone mineral density in diabetic osteoporosis rats[J].Chinese Journal of Medical Physics,2018,35(6):843.[doi:DOI:10.3969/j.issn.1005-202X.2018.07.020]
[6]解琪琪,李文洲,邓亚军,等.糖尿病对去势大鼠骨生物力学的影响[J].中国医学物理学杂志,2018,35(9):1099.[doi:10.3969/j.issn.1005-202X.2018.09.019]
 XIE Qiqi,LIWenzhou,DENG Yajun,et al.Effects of diabetes on bone biomechanics in ovariectomized rats[J].Chinese Journal of Medical Physics,2018,35(6):1099.[doi:10.3969/j.issn.1005-202X.2018.09.019]
[7]王警建,李娜,王龙龙,等. 能谱CT鉴别肺部炎性病变和肺癌的临床价值[J].中国医学物理学杂志,2018,35(10):1164.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.010]
 WANG Jingjian,LI Na,WANG Longlong,et al. Clinical value of energy spectrum CT for the differential diagnosis of pulmonary inflammatory lesion and lung cancer[J].Chinese Journal of Medical Physics,2018,35(6):1164.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.010]
[8]韩蕾,柯晓艾,周青,等. 能谱CT在胰腺疾病诊断中的应用进展[J].中国医学物理学杂志,2019,36(2):190.[doi:DOI:10.3969/j.issn.1005-202X.2019.02.013]
 HAN Lei,KE Xiaoai,ZHOU Qing,et al. Progress on application of spectral CT in the diagnosis of pancreatic diseases[J].Chinese Journal of Medical Physics,2019,36(6):190.[doi:DOI:10.3969/j.issn.1005-202X.2019.02.013]
[9]邓亚军,韩蕾,解琪琪,等. 能谱CT与DXA测量骨密度准确性的比较研究[J].中国医学物理学杂志,2019,36(2):194.[doi:DOI:10.3969/j.issn.1005-202X.2019.02.014]
 DENG Yajun,HAN Lei,et al. Comparison of the accuracy of bone mineral density measurement by spectral CT vs DXA[J].Chinese Journal of Medical Physics,2019,36(6):194.[doi:DOI:10.3969/j.issn.1005-202X.2019.02.014]
[10]彭海洲,张孜君,赵文,等. 核磁共振成像影像测量表观扩散系数、信号强度比值与骨质疏松腰椎疾病发生发展的关系[J].中国医学物理学杂志,2019,36(6):689.[doi:DOI:10.3969/j.issn.1005-202X.2019.06.013]
 PENG Haizhou,ZHANG Zijun,ZHAO Wen,et al. Relationship between the MRI measurements of apparent diffusion coefficient and signal intensity ratio and the development of osteoporostic lumbar vertebrae[J].Chinese Journal of Medical Physics,2019,36(6):689.[doi:DOI:10.3969/j.issn.1005-202X.2019.06.013]
[11]董强,解琪琪,赵若辰,等. 能谱CT定量参数与骨生物力学的相关性[J].中国医学物理学杂志,2018,35(8):978.[doi:DOI:10.3969/j.issn.1005-202X.2018.08.021]
 DONG Qiang,XIE Qiqi,et al. Correlation between energy spectrum CT quantitative parameters and bone biomechanics[J].Chinese Journal of Medical Physics,2018,35(6):978.[doi:DOI:10.3969/j.issn.1005-202X.2018.08.021]

备注/Memo

备注/Memo:
 【收稿日期】2018-04-12
【基金项目】国家自然科学基金(81772006)
【作者简介】黄晓宇,硕士研究生,研究方向:神经影像,E-mail: huangxiaoyuyx@163.com
【通信作者】周俊林,博士,主任医师,教授,研究方向:神经影像,E-mail: zjl601@163.com
更新日期/Last Update: 2018-06-22