[1]胡志,余晓锷,康立丽,等. 基于一种体模对CT能谱技术的质量检测[J].中国医学物理学杂志,2018,35(1):54-59.[doi:DOI:10.3969/j.issn.1005-202X.2018.01.011]
 HU Zhi,YU Xiaoe,KANG Lili,et al. Phantom-based quality testing for spectral computed tomography technology[J].Chinese Journal of Medical Physics,2018,35(1):54-59.[doi:DOI:10.3969/j.issn.1005-202X.2018.01.011]
点击复制

 基于一种体模对CT能谱技术的质量检测()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
35卷
期数:
2018年第1期
页码:
54-59
栏目:
医学影像物理
出版日期:
2018-02-07

文章信息/Info

Title:
 Phantom-based quality testing for spectral computed tomography technology
文章编号:
1005-202X(2018)01-0054-06
作者:
 胡志1余晓锷1康立丽1杨绍洲2陈宏文3王凡3
 1.南方医科大学生物医学工程学院, 广东 广州 510515; 2.南方医科大学中西医结合医院, 广东 广州 510315; 3.南方医科大学南方医院, 广东 广州 510515
Author(s):
 HU Zhi1 YU Xiao’e1 KANG Lili1 YANG Shaozhou2 CHEN Hongwen3 WANG Fan3
 1. School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China; 2. TCM-Integrated Cancer Center of Southern Medical University, Guangzhou 510315, China; 3. Nanfang Hospital, Southern Medical University, Guangzhou 510515, China
关键词:
能谱CT定量分析体模成像技术质量保证
Keywords:
 Keywords: spectral computed tomography quantitative analysis phantom imaging technology iodine quality assurance
分类号:
R318.6;R814.42
DOI:
DOI:10.3969/j.issn.1005-202X.2018.01.011
文献标志码:
A
摘要:
 目的:探讨CT能谱成像技术的质量检测方法。 方法:采用自行制作的碘试剂原型体模在西门子force双源CT和GE Discovery CT750 CT上,运用常用头部条件进行能量扫描实验,然后用双方的后处理工作站上进行图像定量分析。 结果:在临床常用的单能量模式下,得到两者在60、70、80 keV能谱图像,经过对比两者的CT值吻合,再通过能谱成像等功能软件如等效原子序数直方图、基质散点分布图和CT值随射线能量变化曲线图,实现对不同浓度的碘溶液进行区分和定量分析其碘基含量。 结论:经过利用原型体模分别对西门子force双源CT和GE 750能谱CT进行一系列的能谱扫描实验,证明该体模检测CT能谱成像技术的质量是可行的。
Abstract:
 Abstract: Objective To discuss the quality testing method for spectral computed tomography (CT) technology. Methods Based on the conditions for head scan, we used a self-produced iodine reagent phantom to carry out energy scanning experiments on SIEMENS force dual-source CT and GE Discovery CT750 CT. The obtained images were quantitatively analyzed by the post-processing workstation of the two CT systems. Results In the single-energy mode, the spectral CT images under the energy of 60, 70 and 80 keV were obtained, and the obtained images on the two CT systems had agreement CT values. The iodine radical content in iodine solution with different concentrations was distinguished and quantitatively analyzed with the spectral imaging software such as equivalent atomic number matrix histogram, matrix scatter diagram and CT value-energy curves. Conclusion The energy scanning experiments using self-produced iodine reagent phantom on SIEMENS force dual-source CT and GE Discovery CT750 CT verify that using the proposed self-produced iodine reagent phantom for the quality assurance of spectral CT technology is feasible.

相似文献/References:

[1]凌茵,王莎莎,陈泽鹏,等. 超声造影评估兔人工骨血管化的实验研究[J].中国医学物理学杂志,2017,34(5):445.[doi:DOI:10.3969/j.issn.1005-202X.2017.05.003]
[2]黄晓宇,解琪琪,邓亚军,等. 能谱CT评估生物力学的初步研究[J].中国医学物理学杂志,2018,35(6):720.[doi:DOI:10.3969/j.issn.1005-202X.2018.06.018]
 HUANG Xiaoyu,XIE Qiqi,DENG Yajun,et al. Preliminary study of evaluating biomechanics with energy spectral computed tomography[J].Chinese Journal of Medical Physics,2018,35(1):720.[doi:DOI:10.3969/j.issn.1005-202X.2018.06.018]
[3]董强,解琪琪,赵若辰,等. 能谱CT定量参数与骨生物力学的相关性[J].中国医学物理学杂志,2018,35(8):978.[doi:DOI:10.3969/j.issn.1005-202X.2018.08.021]
 DONG Qiang,XIE Qiqi,et al. Correlation between energy spectrum CT quantitative parameters and bone biomechanics[J].Chinese Journal of Medical Physics,2018,35(1):978.[doi:DOI:10.3969/j.issn.1005-202X.2018.08.021]
[4]王警建,李娜,王龙龙,等. 能谱CT鉴别肺部炎性病变和肺癌的临床价值[J].中国医学物理学杂志,2018,35(10):1164.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.010]
 WANG Jingjian,LI Na,WANG Longlong,et al. Clinical value of energy spectrum CT for the differential diagnosis of pulmonary inflammatory lesion and lung cancer[J].Chinese Journal of Medical Physics,2018,35(1):1164.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.010]
[5]韩蕾,柯晓艾,周青,等. 能谱CT在胰腺疾病诊断中的应用进展[J].中国医学物理学杂志,2019,36(2):190.[doi:DOI:10.3969/j.issn.1005-202X.2019.02.013]
 HAN Lei,KE Xiaoai,ZHOU Qing,et al. Progress on application of spectral CT in the diagnosis of pancreatic diseases[J].Chinese Journal of Medical Physics,2019,36(1):190.[doi:DOI:10.3969/j.issn.1005-202X.2019.02.013]
[6]邓亚军,韩蕾,解琪琪,等. 能谱CT与DXA测量骨密度准确性的比较研究[J].中国医学物理学杂志,2019,36(2):194.[doi:DOI:10.3969/j.issn.1005-202X.2019.02.014]
 DENG Yajun,HAN Lei,et al. Comparison of the accuracy of bone mineral density measurement by spectral CT vs DXA[J].Chinese Journal of Medical Physics,2019,36(1):194.[doi:DOI:10.3969/j.issn.1005-202X.2019.02.014]
[7]王金媛,徐寿平,刘博,等.定量评价Atlas模板库病例数目对宫颈癌危及器官自动勾画的影响[J].中国医学物理学杂志,2019,36(7):760.[doi:DOI:10.3969/j.issn.1005-202X.2019.07.004]
 WANG Jinyuan,XU Shouping,LIU Bo,et al.Quantitative evaluation of Atlas-based auto-segmentation of organs-at-risk in patients with cervicalcancer using different Atlas database sizes[J].Chinese Journal of Medical Physics,2019,36(1):760.[doi:DOI:10.3969/j.issn.1005-202X.2019.07.004]
[8]解琪琪,史卫东,李文洲,等. 宝石能谱CT在骨骼系统中的应用进展[J].中国医学物理学杂志,2019,36(10):1173.[doi:DOI:10.3969/j.issn.1005-202X.2019.10.011]
 XIE Qiqi,SHI Weidong,et al. Progress on the application of gemstone spectral CT in skeletal system[J].Chinese Journal of Medical Physics,2019,36(1):1173.[doi:DOI:10.3969/j.issn.1005-202X.2019.10.011]
[9]任占丽,雷雨欣,陈晓侠,等. 能谱CT基物质分离技术在肝硬化与正常肝脏血流定量研究中的应用[J].中国医学物理学杂志,2019,36(10):1200.[doi:DOI:10.3969/j.issn.1005-202X.2019.10.017]
 REN Zhanli,LEI Yuxin,CHEN Xiaoxia,et al. Application of basis material decomposition technique with energy spectral CT in the quantitative study on blood flows in cirrhotic liver and healthy liver[J].Chinese Journal of Medical Physics,2019,36(1):1200.[doi:DOI:10.3969/j.issn.1005-202X.2019.10.017]
[10]冀鲲鹏,任基伟,靳宏星.能谱CT扫描在周围型肺癌分型中的应用[J].中国医学物理学杂志,2020,37(5):608.[doi:10.3969/j.issn.1005-202X.2020.05.015]
 JI Kunpeng,REN Jiwei,JIN Hongxing.Application of energy spectrum CT scanning in the typing of peripheral lung cancer[J].Chinese Journal of Medical Physics,2020,37(1):608.[doi:10.3969/j.issn.1005-202X.2020.05.015]

备注/Memo

备注/Memo:
 【收稿日期】2017-10-22
【基金项目】广东省科技计划项目(2015A030401038)
【作者简介】胡志,高级工程师,研究方向:大型医疗影像设备的维修、质控管理,E-mail: 103610132@qq.com
【通信作者】余晓锷,教授,研究方向:医学物理学、大型医疗设备质量保证,E-mail: 877057376@qq.com
更新日期/Last Update: 2018-01-25