[1]李长虎,李霞,傅玉川,等.利用公开数据集进行商用形变配准系统的准确度评估[J].中国医学物理学杂志,2026,43(7):898-904.[doi:DOI:10.3969/j.issn.1005-202X.2026.07.009]
 LI Changhu,LI Xia,FU Yuchuan,et al.Accuracy evaluation of commercial deformation registration systems using public datasets[J].Chinese Journal of Medical Physics,2026,43(7):898-904.[doi:DOI:10.3969/j.issn.1005-202X.2026.07.009]
点击复制

利用公开数据集进行商用形变配准系统的准确度评估()

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
43卷
期数:
2026年第7期
页码:
898-904
栏目:
医学影像物理
出版日期:
2026-07-22

文章信息/Info

Title:
Accuracy evaluation of commercial deformation registration systems using public datasets
文章编号:
1005-202X(2026)07-0898-07
作者:
李长虎李霞傅玉川曾宪虎
四川大学华西医院肿瘤中心/放射物理技术中心, 四川 成都 610041
Author(s):
LI Changhu LI Xia FU Yuchuan ZENG Xianhu
Radiotherapy Physics and Technology Center/Cancer Center, West China Hospital, Sichuan University, Chengdu 610041, China
关键词:
图像形变配准自适应放射治疗四维计算机断层扫描目标配准误差质量控制
Keywords:
Keywords: deformable image registration adaptive radiotherapy four-dimensiond computed tomography target registration error quality control
分类号:
R318;R811.1
DOI:
DOI:10.3969/j.issn.1005-202X.2026.07.009
文献标志码:
A
摘要:
目的:利用公开数据集评估商用形变配准系统不同形变配准算法在胸部图像配准中的准确性。方法:通过注册获得美国埃默里大学医学院DIR实验室(www.DIR-lab.com)提供的10例胸部癌症患者4D-CT图像数据集的使用授权,该数据集包含由胸部影像学专家手动识别和配准的解剖标识及其相应的坐标信息,通过比较吸气末时相和呼气末时相图像之间点与点的对应关系,评估RayStation治疗计划系统和MIM软件两种商用系统形变配准算法的配准精度。结果:RayStation系统中生物力学算法以及混合强度算法的Control POI、Control ROI和Focus ROI 3种配准模式以及MIM系统中Image based配准算法的目标配准误差范围分别为:0.20~30.50 mm、0.00~28.20 mm、0.10~31.70 mm,0.00~31.00 mm以及0.09~32.45 mm,通过不同患者和不同配准模式之间的误差分布以及统计学分析可以看出各种配准算法应用于不同患者时有很大的变化,不同的DIR算法给出的匹配结果是有差异的。结论:基于本文的评估方法可进行临床实践中商用形变配准系统形变配准算法几何精度的定量化验证。
Abstract:
Abstract: Objective To evaluate the accuracy of various deformable image registration (DIR) algorithms integrated in commercial systems for thoracic image registration using publicly available datasets. Methods Permission to utilize the 4D-CT image dataset containing 10 thoracic cancer patients, provided by the DIR Lab at Emory University School of Medicine (www.DIR-lab.com), was obtained after official registration. This dataset included anatomical landmarks identified and registered by thoracic imaging experts, together with detailed coordinate lists. Precise point-to-point correspondences between end-inspiratory and end-expiratory phase images were established to evaluate the registration accuracy of different DIR algorithms integrated in the Raystation treatment planning system and MIM software. Results For the RayStation system, the target registration error ranges of the evaluated algorithms were as follows: Biomechanical (0.20-30.50 mm), Control POI (0.00-28.20 mm), Control ROI (0.10-31.70 mm), and Focus ROI (0.00-31.00 mm). For the image based registration algorithm in the MIM system, the target registration error range was 0.09-32.45 mm. The error distribution across patients and registration modes and statistical analysis demonstrated significant inter-patient variability for each registration algorithm. Notably, different DIR algorithms produced markedly varying registration outcomes. Conclusion: The proposed evaluation method enables quantitative verification of the geometric accuracy of DIR algorithms embedded in commercial systems for clinical practice.

相似文献/References:

[1]周祥,张书旭.鼻咽癌自适应放疗时腮腺保护的研究进展[J].中国医学物理学杂志,2016,33(3):258.[doi:DOI:10.3969/j.issn.1005-202X.2016.03.008]
 [J].Chinese Journal of Medical Physics,2016,33(7):258.[doi:DOI:10.3969/j.issn.1005-202X.2016.03.008]
[2]门阔,戴建荣,陈辛元,等. 双能锥形束CT线性混合技术提高相对电子密度的准确性[J].中国医学物理学杂志,2017,34(5):433.[doi:DOI:10.3969/j.issn.1005-202X.2017.05.001]
[3]梁有腾,余辉,张书旭. 基于3种配准方法的宫颈癌外照射放疗累积剂量研究[J].中国医学物理学杂志,2018,35(2):151.[doi:DOI:10.3969/j.issn.1005-202X.2018.02.006]
 LIANG Youteng,YU Hui,ZHANG Shuxu. Accumulated dose in external radiation for cervical cancer based on three registration methods[J].Chinese Journal of Medical Physics,2018,35(7):151.[doi:DOI:10.3969/j.issn.1005-202X.2018.02.006]

备注/Memo

备注/Memo:
【收稿日期】2026-03-21 【基金项目】国家自然科学基金(12405391) 【作者简介】李长虎,放射治疗物理师,研究方向:放射治疗流程控制及质量保证;E-mail: chli@scu.edu.cn 【通信作者】傅玉川,主任技师,研究方向:医学物理,E-mail: ychfu@ hotmail.com
更新日期/Last Update: 2026-07-22