[1]张建平.基于体素的射波刀肺追踪剂量覆盖率体积直方图研究[J].中国医学物理学杂志,2024,41(11):1343-1348.[doi:DOI:10.3969/j.issn.1005-202X.2024.11.004]
 ZHANG Jianping,Dose-coverage rate volume histogram for lung tracking with Cyberknife based on voxels[J].Chinese Journal of Medical Physics,2024,41(11):1343-1348.[doi:DOI:10.3969/j.issn.1005-202X.2024.11.004]
点击复制

基于体素的射波刀肺追踪剂量覆盖率体积直方图研究()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
41卷
期数:
2024年第11期
页码:
1343-1348
栏目:
医学放射物理
出版日期:
2024-11-26

文章信息/Info

Title:
Dose-coverage rate volume histogram for lung tracking with Cyberknife based on voxels
文章编号:
1005-202X(2024)11-1343-06
作者:
张建平12
1.福建医科大学附属协和医院放射治疗科, 福建 福州 350001; 2.福建省消化、血液系统与乳腺恶性肿瘤放射与治疗临床医学研究中心, 福建 福州 350001
Author(s):
ZHANG Jianping1 2
1. Department of Radiation Oncology, Fujian Medical University Union Hospital, Fuzhou 350001, China 2. Fujian Clinical Research Center for Radiology and Radiotherapy for Digestive, Hematological and Breast Malignancies, Fuzhou 350001, China
关键词:
射波刀肺追踪治疗分次剂量覆盖率体积直方图
Keywords:
Keywords: Cyberknife lung tracking treatment fractionation dose-coverage rate volume histogram
分类号:
R811.1
DOI:
DOI:10.3969/j.issn.1005-202X.2024.11.004
文献标志码:
A
摘要:
目的:基于体素计算分次间射波刀肺追踪的剂量覆盖率体积直方图(CVH),并探讨肿瘤体积、解剖位置与CVH鲁棒性之间的相关性。方法:回顾性分析外周型肺癌患者55例(上肺26例,中肺22例,下肺7例),共339分次。所有患者均采用射波刀(VSI型)Xsight Lung追踪(2-view)方式进行治疗,拍片时间间隔为60 s。在射波刀的动态追踪系统(MTS)中记录的呼吸追踪数据均转化为患者坐标系。以射波刀治疗时产生的log文件为基础,基于体素利用MATLAB科学计算软件计算不同外扩范围下的CVH,并讨论肿瘤体积、解剖位置与CVH鲁棒性之间的相关性。结果:采用95%靶区覆盖率(C95)大于95%即C95>95%作为是否满足临床要求的评价指标,满足临床要求的计划在整个治疗疗程内并非所有治疗分次都能达到评价指标。对于同一外扩范围,其CVH由大到小依次为:上肺>中肺>下肺。另外,对于中、下肺而言,肿瘤外扩5 mm并不能满足临床评价指标即C95>95%。肿瘤体积和治疗过程中CVH的鲁棒性之间呈负相关。肿瘤体积越大治疗过程中的CVH波动越小,反之,肿瘤体积越小,治疗期间覆盖率的不确定度越大,鲁棒性越差。对于下肺肿瘤,上述现象更加明显。另外,随着外扩范围的增加,CVH的鲁棒性也逐渐上升。结论:对于小体积和下肺肿瘤的治疗,平均覆盖率小于大体积和上肺肿瘤,治疗过程中应根据患者肿瘤体积、位置等因素综合考虑外放范围,以进一步提高临床疗效。
Abstract:
Abstract: Objective To calculate the inter-fractional dose-coverage rate volume histogram (CVH) of Cyberknife Xsight lung tracking based on voxels, and to investigate the correlation among tumor volume, anatomical location and CVH robustness. Methods A retrospective analysis was conducted on 55 peripheral lung cancer patients, with 26 in upper lobe, 22 in middle lobe and 7 in lower lobe, and there were 399 fractions. All patients were treated with Cyberknife (VSI) Xsight Lung tracking (2-view), with a scanning time interval of 60 s. The respiration tracking data recorded in Cyberknife motion tracking system were converted into patient coordinates. Based on the log files generated during Cyberknife treatment, the CVH of different margins were calculated with MATLAB on a voxel scale, and the correlation among anatomical location, tumor volume and CVH robustness was discussed. Results The target coverage rate (coverage of 95%, C95) greater than 95%, that is C95>95%, was taken as the evaluation criterion of whether the clinical requirements were met. Not coverage rate of all fractions met the clinical requirement when an evaluable treatment plan was delivered during treatment course. For the same margin, the value of CVH in order from the largest to the smallest was: upper lobe > middle lobe > lower lobe. The margin of 5 mm wont met the criterion of C95>95% for lung cancer in middle and lower lobes. There was a negative correlation between tumor volume and CVH robustness during treatment. The larger the tumor size, the smaller the fluctuation of CVH conversely, the smaller the tumor size, the greater the uncertainty of coverage during treatment and the poorer the robustness. For lower lobe lung tumors, the above phenomenon was more obvious. Additionally, CVH robustness improved with increasing margin. Conclusion For small volume and lower lobe lung tumors, the average coverage rate is lower than that of large volume and upper lobe lung tumor, and the margin should be comprehensively considered based on the factors such as tumor volume and location for further improving clinical efficacy.

相似文献/References:

[1]王小深,鞠忠建,解传滨,等.射波刀准直器个数对脊柱转移瘤放疗计划的影响[J].中国医学物理学杂志,2016,33(2):195.[doi:10.3969/j.issn.1005-202X.2016.02.018]
[2]曹洋森,于春山,张火俊.射波刀关节限制联锁的解决方案[J].中国医学物理学杂志,2016,33(5):522.[doi:10.3969/j.issn.1005-202X.2016.05.018]
 [J].Chinese Journal of Medical Physics,2016,33(11):522.[doi:10.3969/j.issn.1005-202X.2016.05.018]
[3]曹洋森,于春山,张火俊,等.射波刀Monte Carlo与Ray-Tracing算法在胰腺癌中的剂量学比较[J].中国医学物理学杂志,2016,33(10):1008.[doi:10.3969/j.issn.1005-202X.2016.10.007]
 [J].Chinese Journal of Medical Physics,2016,33(11):1008.[doi:10.3969/j.issn.1005-202X.2016.10.007]
[4]赵瑞,李莎,陆军,等.射波刀颅骨追踪俯卧位与仰卧位治疗精度对比[J].中国医学物理学杂志,2017,34(8):790.[doi:DOI:10.3969/j.issn.1005-202X.2017.08.007]
[5]王朝壮,王鑫,王恩敏,等. 不同厚度CT图像重建的DRR对射波刀治疗头部肿瘤精度的影响[J].中国医学物理学杂志,2017,34(9):882.[doi:DOI:10.3969/j.issn.1005-202X.2017.09.005]
 [J].Chinese Journal of Medical Physics,2017,34(11):882.[doi:DOI:10.3969/j.issn.1005-202X.2017.09.005]
[6]杨晶,柳刚,聂鑫,等. 基于仿真头颈模体研究处方等剂量线对射波刀计划质量的影响[J].中国医学物理学杂志,2018,35(12):1371.[doi:DOI:10.3969/j.issn.1005-202X.2018.12.002]
 YANG Jing,LIU Gang,NIE Xin,et al. Effect of prescription isodose line on the quality of CyberKnife plan designed on anthropomorphic head and neck phantom[J].Chinese Journal of Medical Physics,2018,35(11):1371.[doi:DOI:10.3969/j.issn.1005-202X.2018.12.002]
[7]周含,李傲梅,景生华,等. 射波刀计划设计中治疗路径选择对靶区剂量分布的影响[J].中国医学物理学杂志,2018,35(12):1408.[doi:DOI:10.3969/j.issn.1005-202X.2018.12.008]
 ZHOU Han,LI Aomei,JING Shenghua,et al. Effects of treatment paths on target dosimetric distribution in CyberKnife radiotherapy plan[J].Chinese Journal of Medical Physics,2018,35(11):1408.[doi:DOI:10.3969/j.issn.1005-202X.2018.12.008]
[8]葛瑞刚,解传滨,戴相昆,等.D2SRS两种照射技术与CyberKnife在脑转移瘤立体定向放疗中的剂量学研究[J].中国医学物理学杂志,2020,37(3):265.[doi:DOI:10.3969/j.issn.1005-202X.2020.03.001]
 GE Ruigang,XIE Chuanbin,DAI Xiangkun,et al.Dosimetric comparison of two kinds of radiation techniques of D2SRS and CyberKnife in stereotactic radiotherapy for brain metastases[J].Chinese Journal of Medical Physics,2020,37(11):265.[doi:DOI:10.3969/j.issn.1005-202X.2020.03.001]
[9]景生华,李傲梅,季小芹,等.金标伪影对射波刀剂量计算及分布的影响[J].中国医学物理学杂志,2020,37(8):996.[doi:DOI:10.3969/j.issn.1005-202X.2020.08.011]
 JING Sheng-hua,LI Ao-mei,JI Xiao-qin,et al.Effects of fiducial artifact on dose calculation and distribution of Cyberknife treatment[J].Chinese Journal of Medical Physics,2020,37(11):996.[doi:DOI:10.3969/j.issn.1005-202X.2020.08.011]
[10]王琳.位置重复性对射波刀模体绝对剂量验证的影响[J].中国医学物理学杂志,2020,37(9):1107.[doi:10.3969/j.issn.1005-202X.2020.09.005]
 WANG Lin.Effect of position repeatability on the verification of absolute dose for CyberKnife[J].Chinese Journal of Medical Physics,2020,37(11):1107.[doi:10.3969/j.issn.1005-202X.2020.09.005]

备注/Memo

备注/Memo:
【收稿日期】2024-05-15 【基金项目】福建省中青年教师教育科研项目(JAT200165) 【作者简介】张建平,硕士,工程师,研究方向:立体定向放射治疗及放射生物,E-mail: zhangjianpn@126.com
更新日期/Last Update: 2024-11-26