[1]刘姝言,等.锥形束CT图像引导乳腺癌放疗中不同配准方法研究[J].中国医学物理学杂志,2023,40(1):7-12.[doi:DOI:10.3969/j.issn.1005-202X.2023.01.002]
 LIU Shuyan,GAO Xingwang,et al.Comparison of different registration methods in cone beam CT image guided radiotherapy for breast cancer[J].Chinese Journal of Medical Physics,2023,40(1):7-12.[doi:DOI:10.3969/j.issn.1005-202X.2023.01.002]
点击复制

锥形束CT图像引导乳腺癌放疗中不同配准方法研究()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
40卷
期数:
2023年第1期
页码:
7-12
栏目:
医学放射物理
出版日期:
2023-01-07

文章信息/Info

Title:
Comparison of different registration methods in cone beam CT image guided radiotherapy for breast cancer
文章编号:
1005-202X(2023)01-0007-06
作者:
刘姝言1 2高兴旺3刘懿梅1周杨4邓小武1陈仲本5彭应林1
1.中山大学肿瘤防治中心/华南肿瘤学国家实验室/肿瘤医学协同创新中心, 广东 广州 510060; 2.中山大学附属第一医院, 广东 广州 510062; 3.国家癌症中心/国家肿瘤临床医学研究中心/中国医学科学院北京协和医学院肿瘤医院深圳医院, 广东 深圳 518116; 4.中南大学湘雅医学院附属株洲医院, 湖南 株洲412000; 5.中山大学新华学院, 广东 广州 510520
Author(s):
LIU Shuyan1 2 GAO Xingwang3 LIU Yimei1 ZHOU Yang4 DENG Xiaowu1 CHEN Zhongben5 PENG Yinglin1
1. Department of Radiation Oncology, Sun Yat-sen University Cancer Center/State Key Laboratory of Oncology in Southern China/Collaborative Innovation Center for Cancer Medicine, Guangzhou 510060, China 2. The First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510062, China 3. Shenzhen Hospital, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital of Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen 518116, China 4. Zhuzhou Hospital Affiliated to Xiangya School of Medicine, Central South University, Zhuzhou 412000, China 5. Xinhua College of Sun Yat-sen University, Guangzhou 510520, China
关键词:
乳腺癌图像引导放射治疗锥形束CT摆位误差图像配准六维床
Keywords:
Keywords: breast cancer image-guided radiotherapy cone beam CT positioning error image registration six-dimensional couch
分类号:
R318;R811.1
DOI:
DOI:10.3969/j.issn.1005-202X.2023.01.002
文献标志码:
A
摘要:
目的:比较锥形束CT(CBCT)图像引导乳腺癌放疗中采用不同配准方法[3D配准(平移)和6D配准(平移+旋转)]对配准精度的影响,为选择合理的图像引导方法提供临床依据。方法:回顾性分析18例乳腺癌患者共101次治疗前摆位CBCT图像,将CBCT图像与计划CT图像分别采用3D灰度配准和6D灰度配准方法进行配准,比较和分析两种配准方法的3D平移方向的配准偏差差异并计算其平移差别,进一步统计分析旋转角度偏差与平移差别的相关性并做线性模拟。结果:3D和6D两种配准方法得到不同的平移配准结果,其中在头脚(Y)方向[(-1.47±3.00) mm vs (-0.87±3.27) mm]和前后(Z)方向[(-2.91±4.49) mm vs (-3.41±5.38) mm]的差异存在统计学意义(P<0.001)。旋转角度偏差与平移差别存在相关性,其中ΔX和ΔZ均与Ry呈线性强相关性,其相关系数PCC分别为-0.883和0.795(P<0.001);ΔY与Rx呈线性强负相关性,PCC=-0.722(P<0.001)。根据线性模拟公式计算,当Rx>1°且Ry>2°时,两种配准方法将在各平移方向上存在将近1 mm的平移差别。结论:3D和6D平移配准结果的差异具有统计学意义。6D配准的旋转角度大小影响平移差别的大小,其中Ry影响最大。建议使用6D配准方法时应使用六维床进行6D偏差修正,以减小平移差别的影响。 【关键词】乳腺癌;图像引导放射治疗;锥形束CT;摆位误差;图像配准;六维床
Abstract:
Abstract: Objective To compare the effects of three-dimensional (3D) registration (translation only) and six-dimensional (6D) registration (translation+rotation) on registration accuracy in cone beam CT (CBCT) image guided radiotherapy for breast cancer for providing clinical basis for selecting the optimal image guidance method. Methods The positioning CBCT images before 101 treatments in 18 patients with breast cancer were retrospectively analyzed. The CBCT images and planned CT images were registered by 3D grey-scale image registration and 6D grey-scale image registration, separately. The registration deviation differences in the 3D translation directions of the two registration methods were compared and analyzed and the translation difference (Δ) was calculated. Furthermore, the correlation between rotation angle deviation (R) and translation difference (Δ) was statistically analyzed, and a linear simulation was carried out. Results 3D and 6D registration methods had different translation registration results, in which there were statistical differences in superior-inferior (Y) direction and anterior-posterior (Z) directions [(-1.47±3.00) mm vs (-0.87±3.27) mm, (-2.91±4.49) mm vs (-3.41±5.38) mm P<0.001]. The rotation angle deviation (R) was correlated with the translation difference (Δ). ΔX and ΔZ had strong linear correlations with Ry (PCC=-0.883, 0.795 P<0.001), and there was a strong linear negative correlation between ΔY and Rx (PCC=-0.722, P<0.001). According to the linear simulation formula, when Rx was greater than 1° and Ry was greater than 2°, there was nearly 1 mm translation difference between the two registration methods in each translation direction. Conclusion The 3D translation registration results significantly differ from 6D translation registration results. The rotation angle of 6D registration affects the translation difference, among which Ry has the greatest impact. It is suggested that when using 6D registration method, 6D couch should be used to correct 6D deviations in order to reduce the effects of translation difference.

相似文献/References:

[1]柏 晗,王 丽,刘旭红,等.左乳腺5种不同主野分布IMRT计划的剂量比较分析[J].中国医学物理学杂志,2015,32(02):210.[doi:10.3969/j.issn.1005-202X.2015.02.013]
[2]张晋建,黎 静,文 婷,等.Arc CHECK在乳腺癌螺旋断层放疗计划剂量验证中的应用[J].中国医学物理学杂志,2015,32(02):244.[doi:10.3969/j.issn.1005-202X.2015.02.021]
[3]白 雪,杜向慧,王升晔,等.半野技术结合非共面照射技术在乳腺癌胸锁联合照射中的应用[J].中国医学物理学杂志,2014,31(03):4849.[doi:10.3969/j.issn.1005-202X.2014.03.001]
[4]赵永亮,储开岳,吴建亭,等.两种不同调强技术配合主动呼吸控制系统在乳腺癌放疗中的比较[J].中国医学物理学杂志,2014,31(03):4862.[doi:10.3969/j.issn.1005-202X.2014.03.004]
[5]沈奕晨,聂生东.锥形束CT与螺旋CT图像配准算法及其在放疗中的应用[J].中国医学物理学杂志,2014,31(05):5151.[doi:10.3969/j.issn.1005-202X.2014.05.013]
[6]林俊华,魏贤顶,孔旭东,等.kV级锥形束CT在图像引导放疗中的应用[J].中国医学物理学杂志,2014,31(05):5157.[doi:10.3969/j.issn.1005-202X.2014.05.014]
[7]周永强,金献测,易金玲,等.锥形束CT的验收与QA探讨[J].中国医学物理学杂志,2013,30(01):3854.[doi:10.3969/j.issn.1005-202X.2013.01.005]
[8]花威,张西志,张先稳,等.RapidArc在乳腺癌术后放疗中的应用[J].中国医学物理学杂志,2013,30(02):3984.[doi:10.3969/j.issn.1005-202X.2013.02.005]
[9]张淑慧,杨敬贤,贾飞,等.肿瘤立体定向放射治疗摆位误差分析与质量控制[J].中国医学物理学杂志,2013,30(02):3988.[doi:10.3969/j.issn.1005-202X.2013.02.006]
[10]徐金济,成俊,李伟,等.左侧乳腺癌改良根治术后逆向调强放射治疗的摆位误差分析[J].中国医学物理学杂志,2013,30(05):4358.[doi:10.3969/j.issn.1005-202X.2013.05.004]

备注/Memo

备注/Memo:
【收稿日期】2022-05-14 【基金项目】国家自然科学基金(12005316);中华国际医学交流基金会肿瘤精准放疗星火计划(2019-N-11-20);广州市科技计划项目(202206010154,202206010180);广州新华学院大学生创新创业训练项目(202113902007) 【作者简介】刘姝言,研究方向:肿瘤放射治疗物理学,E-mail: liusy0826@163.com 【通信作者】彭应林,助理研究员,研究方向:肿瘤放射治疗物理学,E-mail: pengyl@sysucc.org.cn
更新日期/Last Update: 2023-01-07