[1]李进,黄玉胜,杨镇洲,等.3D打印组织补偿块在鼻腔NK/T细胞淋巴瘤放疗中的应用[J].中国医学物理学杂志,2021,38(11):1321-1324.[doi:DOI:10.3969/j.issn.1005-202X.2021.11.001]
 LI Jin,HUANG Yusheng,YANG Zhenzhou,et al.Clinical application of 3D printed bolus for nasal natural killer/T-cell lymphoma in radiotherapy[J].Chinese Journal of Medical Physics,2021,38(11):1321-1324.[doi:DOI:10.3969/j.issn.1005-202X.2021.11.001]
点击复制

3D打印组织补偿块在鼻腔NK/T细胞淋巴瘤放疗中的应用()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
38卷
期数:
2021年第11期
页码:
1321-1324
栏目:
医学放射物理
出版日期:
2021-11-26

文章信息/Info

Title:
Clinical application of 3D printed bolus for nasal natural killer/T-cell lymphoma in radiotherapy
文章编号:
1005-202X(2021)11-1321-04
作者:
李进黄玉胜杨镇洲黄顺平
重庆医科大学第二附属医院肿瘤科, 重庆 401336
Author(s):
LI Jin HUANG Yusheng YANG Zhenzhou HUANG Shunping
Department of Oncology, the Second Affiliated Hospital of Chongqing Medical University, Chongqing 401336, China
关键词:
鼻腔NK/T细胞淋巴瘤组织补偿块3D打印技术放射治疗
Keywords:
Keywords: nasal natural killer/T-cell lymphoma bolus 3D printing technology radiotherapy
分类号:
R318;R739.62
DOI:
DOI:10.3969/j.issn.1005-202X.2021.11.001
文献标志码:
A
摘要:
目的:利用3D打印技术为鼻腔NK/T细胞淋巴瘤患者定制个性化的组织补偿块,研究其在放疗计划中的剂量学影响。方法:选取10例早期鼻腔NK/T淋巴瘤患者,分别采用无组织补偿块的常规CTno-bolus图像和3D打印组织补偿块的CTbolus图像进行放疗计划设计,靶区处方剂量均为50 Gy/25次。使用剂量体积直方图评估两种计划中计划靶区、危及器官的剂量学差异。结果:3D打印组织补偿块与体表紧密贴合,提高了靶区的均匀性和适形度;晶体、视神经和腮腺剂量在3D打印组织补偿块计划中均低于无组织补偿块计划(P<0.05)。结论:3D打印组织补偿块有效提高了鼻腔NK/T细胞淋巴瘤紧邻体表靶区的剂量分布,值得临床推广。
Abstract:
Abstract: Objective To prepare a personalized bolus for patients with nasal natural killer (NT)/T-cell lymphoma using 3D printing technology, and to study the dosimetric effect of 3D printed bolus used for nasal NK/Tcell lymphoma in radiotherapy planning. Methods Ten patients with early nasal NK/T-cell lymphoma were enrolled in the study. CT images without bolus (CTno-bolus) and with 3D printed bolus (CTbolus) of each patient were acquired for treatment planning. The prescription dose of planning target volume (PTV) was 50 Gy/25 fractions. The dosimetric differences of PTV and organs-at-risk between two kinds of plans (Planbolus vs Planno-bolus) were evaluated using dose-volume histograms. Results The 3D printed bolus which closely fitted the body surface improved the uniformity and conformity of PTV. The doses to lens, optic nerves and parotids in Planbolus were all lower than those in Planno-bolus (P<0.05). Conclusion 3D printed bolus is worth to be promoted for clinic use for it can effectively improve the dose distribution of nasal NK/T-cell lymphoma target area adjacent to the epidermis.