[1]贺瑶瑶,汪立文,孙哲,等. 等效组织材料聚氯乙烯的医学成像特性[J].中国医学物理学杂志,2019,36(9):1091-1094.[doi:DOI:10.3969/j.issn.1005-202X.2019.09.019]
 HE Yaoyao,,et al. Medical imaging properties of tissue equivalent material of polyvinyl chloride[J].Chinese Journal of Medical Physics,2019,36(9):1091-1094.[doi:DOI:10.3969/j.issn.1005-202X.2019.09.019]
点击复制

 等效组织材料聚氯乙烯的医学成像特性()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
36卷
期数:
2019年第9期
页码:
1091-1094
栏目:
生物材料与力学
出版日期:
2019-09-25

文章信息/Info

Title:
 Medical imaging properties of tissue equivalent material of polyvinyl chloride
文章编号:
1005-202X(2019)09-1091-04
作者:
 贺瑶瑶123汪立文4孙哲123徐志康123郑凤莲123石丽婷123袁子龙5孙勇3邱建峰123
 1.山东第一医科大学(山东省医学科学院)医学工程技术研究中心, 山东 泰安 271016; 2.Imaging-X联合实验室, 山东 泰安 271016; 3.山东第一医科大学(山东省医学科学院)放射学院, 山东 泰安 271016; 4.广州计量检测技术研究院, 广东 广州 510016; 5.湖北省肿瘤医院放射科, 湖北 武汉 430079
Author(s):
 HE Yaoyao1 2 3 WANG Liwen4 SUN Zhe1 2 3 XU Zhikang1 2 3 ZHENG Fenglian1 2 3 SHI Liting1 2 3 YUAN Zilong5 SUN Yong3 QIU Jianfeng1 2 3
 1. Medical Engineering and Technology Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai’an 271016, China; 2. Imaging-X Joint Laboratory, Tai’an, 271016, China; 3. Department of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai’an 271016, China; 4. Guangzhou Institute of Measurement and Testing Technology, Guangzhou 510016, China; 5. Department of Radiology, Hubei Cancer Hospital, Wuhan 430079, China
关键词:
 聚氯乙烯树脂等效组织材料CT值MRI弛豫时间X线衰减系数
Keywords:
 Keywords: polyvinyl chloride tissue equivalent material CT number MRI relaxation time X-ray attenuation coefficient
分类号:
R318.08;R814.4
DOI:
DOI:10.3969/j.issn.1005-202X.2019.09.019
文献标志码:
A
摘要:
 目的:聚氯乙烯树脂(PVC)的光学透明性和硬度与真实组织接近,适用于作为等效组织材料应用于医学领域,本研究旨在探讨不同PVC-增塑剂(对苯二甲酸二辛酯, DOTP)混合比与医学成像特性(如X线衰减系数、CT值和MRI弛豫时间)的关系。方法:不同PVC-DOTP混合比会影响材料的医学成像特性。本实验制作11组不同混合比的PVC聚合物样品,通过测量各组PVC聚合物样品的CT值和MRI弛豫时间,对PVC材料的成像特性进行评估;同时随机抽取5组PVC聚合物样品在不同电压下测量X线衰减系数。结果:当PVC-DOTP混合比范围为8.0×10-2~23.3×10-2 g/mL时,测得平均CT值范围为-0.6~109.0 HU,T1弛豫时间为172.3~203.9 ms,T2弛豫时间为13.7~32.1 ms;在电压为40~120 kV时,样品的X线衰减系数的范围为6~20.8 m-1。结论:PVC聚合物具有可控的CT值和MRI弛豫时间,透光度好,具有一定的粘弹性,可以作为组织等效材料制作医用体模。
Abstract:
 Abstract: Objective Polyvinyl chloride (PVC) which had similar optical transparency and hardness with those of human tissues is suitable for medical applications as tissue equivalent materials. The purpose of this study is to investigate the relationships between different PVC-softener (dioctyl terephthalate, DOTP) mixture ratios and the medical imaging characteristics (such as X-ray attenuation coefficient, CT number and MRI relaxation time). Methods The medical imaging properties of the materials were affected by different PVC-DOTP mixture ratios. Therefore, 11 groups of PVC samples with different mixture ratios were prepared in the study. The medical imaging properties of PVC materials were evaluated by measuring the CT number and MRI relaxation time of PVC samples. Meanwhile, the X-ray attenuation coefficients of 5 groups of PVC samples at different voltages were also measured. Results When the PVC-DOTP mixture ratio ranged from 8.0×10-2 to 23.3×10-2 g/mL, the corresponding average CT number was -0.6 to 109.0 HU, and the T1 and T2 relaxation time was 172.3-203.9 ms and 13.7-32.1 ms, respectively. At the voltage of 40-120 kV, the X-ray attenuation coefficient of the samples was 6.0-20.8 m-1. Conclusion PVC which has controllable CT number and MRI relaxation time, with the advantages of good light transmittance and a certain degree of viscoelasticity, can be used as the tissue equivalent material for medical phantom.

相似文献/References:

[1]王遥,霍万里,熊壮,等.TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较[J].中国医学物理学杂志,2016,33(6):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
 [J].Chinese Journal of Medical Physics,2016,33(9):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
[2]张新,谷晓芳,王培臣,等.轻离子束治疗设备注册检验关键技术问题[J].中国医学物理学杂志,2016,33(6):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
 [J].Chinese Journal of Medical Physics,2016,33(9):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
[3]江芬芬,王培,康盛伟,等. 热释光剂量片测量肺部肿瘤放疗剂量的方法[J].中国医学物理学杂志,2016,33(6):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
 [J].Chinese Journal of Medical Physics,2016,33(9):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
[4]刘洪源,彭威,杨锐,等. 锥形束CT离线校正肺癌摆位误差[J].中国医学物理学杂志,2016,33(6):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
 [J].Chinese Journal of Medical Physics,2016,33(9):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
[5]赵彪,潘香,杨毅,等. 右乳癌保乳术后瘤床同步X线和后程电子线补量调强放疗剂量学比较[J].中国医学物理学杂志,2016,33(6):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
 [J].Chinese Journal of Medical Physics,2016,33(9):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
[6]邓南,钱建庭,刁现芬,等. 基于宽带检测放疗X-光光声效应仿体实验[J].中国医学物理学杂志,2016,33(9):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
 [J].Chinese Journal of Medical Physics,2016,33(9):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
[7]张先稳,李军,张西志,等. 宫颈癌术后5野调强放疗4个变量组合的最佳治疗模式的剂量学[J].中国医学物理学杂志,2016,33(9):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
 [J].Chinese Journal of Medical Physics,2016,33(9):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
[8]胡健,李承军,徐利明,等. 床面倾斜对剂量验证通过率的影响[J].中国医学物理学杂志,2016,33(9):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
 [J].Chinese Journal of Medical Physics,2016,33(9):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
[9]陈亚正,肖明勇,孙春堂,等. 准直器角度对宫颈癌术后VMAT计划的影响[J].中国医学物理学杂志,2016,33(9):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
 [J].Chinese Journal of Medical Physics,2016,33(9):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
[10]李毅,唐丰文,张晓智. 基于四维CT和锥形束CT确定非小细胞肺癌放疗靶区外放边界[J].中国医学物理学杂志,2016,33(9):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]
 [J].Chinese Journal of Medical Physics,2016,33(9):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]

备注/Memo

备注/Memo:
 【收稿日期】2019-03-29
【基金项目】国家重点研发计划(2016YFC0103400);山东省重点研究发展计划(2017GSF218075)
【作者简介】贺瑶瑶,在读研究生,研究方向:医学物理与医学成像,E-mail: heyaoyao628@163.com;汪立文,高级工程师,硕士研究生,研究方向:物理光学计量检测,E-mail: wangliwen2029@163.com
【通信作者】邱建峰,教授,研究方向:医学物理与医学成像,E-mail: jfqiu100@gmail.com
更新日期/Last Update: 2019-09-24