[1]张祥斌,李光俊,张英杰,等. 基于形变配准算法评估前列腺癌分次间剂量的可行性研究[J].中国医学物理学杂志,2019,36(9):995-1000.[doi:DOI:10.3969/j.issn.1005-202X.2019.09.001]
 ZHANG Xiangbin,LI Guangjun,ZHANG Yingjie,et al. Feasibility of deformable image registration algorithm for interfractional dose calculation in radiotherapy for prostate cancer[J].Chinese Journal of Medical Physics,2019,36(9):995-1000.[doi:DOI:10.3969/j.issn.1005-202X.2019.09.001]
点击复制

 基于形变配准算法评估前列腺癌分次间剂量的可行性研究()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
36卷
期数:
2019年第9期
页码:
995-1000
栏目:
医学放射物理
出版日期:
2019-09-25

文章信息/Info

Title:
 Feasibility of deformable image registration algorithm for interfractional dose calculation in radiotherapy for prostate cancer
文章编号:
1005-202X(2019)09-0995-06
作者:
 张祥斌12李光俊1张英杰1柏森12
 1.四川大学华西医院放疗科, 四川 成都 610041; 2.四川大学物理科学与技术学院, 四川 成都 610065
Author(s):
 ZHANG Xiangbin12 LI Guangjun1 ZHANG Yingjie1 BAI Sen12
 1. Department of Radiotherapy, West China Hospital of Sichuan University, Chengdu 610041, China; 2. College of Physical Science and Technology, Sichuan University, Chengdu 610065, China
关键词:
 前列腺癌锥形束CT形变配准自适应放疗
Keywords:
 Keywords: prostate cancer cone beam computed tomography deformable image registration adaptive radiotherapy
分类号:
R318;R811.1
DOI:
DOI:10.3969/j.issn.1005-202X.2019.09.001
文献标志码:
A
摘要:
 【摘要】目的:研究基于形变配准算法进行前列腺癌分次间剂量评估的可行性。方法:采用锥形束CT(CBCT)形变配准到再计划CT,产生有明显配准误差的形变CBCT。分别结合频谱峰值转换法和逐层线性变换法,根据刚性盆部模体的噪声模型来修正形变CBCT,生成与再计划CT解剖结构基本一致的两组虚拟CBCT作为形变配准评估的“金标准”。以再计划CT为基准,评估计划CT形变配准到虚拟CBCT形成的虚拟CT的Gamma通过率。比较两组虚拟CT的评估系数,验证再计划CT转换为虚拟CBCT的可行性。评估基于形变场映射产生感兴趣区域(ROI)的dice系数,验证基于形变配准中产生形变场的半自动勾画技术的可行性。结果:计划CT形变配准到两组虚拟CBCT产生的虚拟CT的1 mm/1%和2 mm/2%的Gamma通过率分别为(98.08±0.43)%/(97.95±0.37)%(P>0.05)和(99.53±0.08)%/(99.55±0.10)%(P>0.05)。基于形变场映射产生各个ROI的dice系数均值为0.78~0.95。结论:虚拟CBCT提供了一种解决形变配准算法缺少“金标准”的问题,并验证基于形变配准算法评估前列腺癌分次间剂量的可行性。
Abstract:
Abstract: Objective To evaluate the feasibility of interfractional dose evaluation based on deformable image registration (DIR) algorithm in the radiotherapy for prostate cancer. Methods A deformed cone beam CT (CBCT) with obvious registration errors was generated by the DIR from cone beam CT (CBCT) to replan CT. Based on the rigid pelvic phantom-based noise model, peak spectrum conversion method and layer-by-layer linear transformation method were used to correct the deformed CBCT and then generate two sets of virtual CBCT in which the anatomical structures were consistent with those in replan CT. The two sets of virtual CBCT were taken as the golden standard of DIR evaluation. The replan CT was taken as the baseline to evaluate the Gamma passing rate of virtual CT generated by the DIR from planned CT to virtual CBCT. The evaluation coefficients of two groups of virtual CT were compared, so as to verify the feasibility of converting replan CT to virtual CBCT. Moreover, the dice coefficient of region of interest generated by deformation field mapping was evaluated, so as to verify the feasibility of semi-automatic segmentation based on the deformation field in DIR. Results The Gamma passing rates (1 mm/1% and 2 mm/2%) of virtual CT derived from two different set of virtual CBCT were(98.08±0.43)%/(97.95±0.37)% (P>0.05) and (99.53±0.08)%/(99.55±0.10)%(P>0.05). The dice similarity coefficient of region of interest generated based on deformation field was 0.78-0.95. Conclusion Virtual CBCT is a promising method to solve the problem that DIR algorithm lacks of golden standard and to verify the feasibility of DIR-based algorithm to evaluate the interfractional dose in the radiotherapy for prostate cancer.

相似文献/References:

[1]王遥,霍万里,熊壮,等.TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较[J].中国医学物理学杂志,2016,33(6):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
 [J].Chinese Journal of Medical Physics,2016,33(9):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
[2]张新,谷晓芳,王培臣,等.轻离子束治疗设备注册检验关键技术问题[J].中国医学物理学杂志,2016,33(6):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
 [J].Chinese Journal of Medical Physics,2016,33(9):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
[3]江芬芬,王培,康盛伟,等. 热释光剂量片测量肺部肿瘤放疗剂量的方法[J].中国医学物理学杂志,2016,33(6):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
 [J].Chinese Journal of Medical Physics,2016,33(9):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
[4]刘洪源,彭威,杨锐,等. 锥形束CT离线校正肺癌摆位误差[J].中国医学物理学杂志,2016,33(6):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
 [J].Chinese Journal of Medical Physics,2016,33(9):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
[5]赵彪,潘香,杨毅,等. 右乳癌保乳术后瘤床同步X线和后程电子线补量调强放疗剂量学比较[J].中国医学物理学杂志,2016,33(6):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
 [J].Chinese Journal of Medical Physics,2016,33(9):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
[6]董晓庆,胡杰,陆春花,等.前列腺癌图像引导放射治疗精准度评估[J].中国医学物理学杂志,2016,33(7):658.[doi:10.3969/j.issn.1005-202X.2016.07.003]
 [J].Chinese Journal of Medical Physics,2016,33(9):658.[doi:10.3969/j.issn.1005-202X.2016.07.003]
[7]邓南,钱建庭,刁现芬,等. 基于宽带检测放疗X-光光声效应仿体实验[J].中国医学物理学杂志,2016,33(9):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
 [J].Chinese Journal of Medical Physics,2016,33(9):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
[8]张先稳,李军,张西志,等. 宫颈癌术后5野调强放疗4个变量组合的最佳治疗模式的剂量学[J].中国医学物理学杂志,2016,33(9):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
 [J].Chinese Journal of Medical Physics,2016,33(9):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
[9]胡健,李承军,徐利明,等. 床面倾斜对剂量验证通过率的影响[J].中国医学物理学杂志,2016,33(9):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
 [J].Chinese Journal of Medical Physics,2016,33(9):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
[10]陈亚正,肖明勇,孙春堂,等. 准直器角度对宫颈癌术后VMAT计划的影响[J].中国医学物理学杂志,2016,33(9):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
 [J].Chinese Journal of Medical Physics,2016,33(9):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
[11]鞠孟阳,史玉静,李金凯,等. 直肠内气腔对前列腺癌放疗计划的影响[J].中国医学物理学杂志,2018,35(8):879.[doi:DOI:10.3969/j.issn.1005-202X.2018.08.003]
 JU Mengyang,SHI Yujing,LI Jinkai,et al. Effects of gas cavity in rectum on radiotherapy plan for prostate cancer[J].Chinese Journal of Medical Physics,2018,35(9):879.[doi:DOI:10.3969/j.issn.1005-202X.2018.08.003]
[12]张君席,刘振湘,张平,等. 基于太赫兹光谱和成像的前列腺癌检测[J].中国医学物理学杂志,2019,36(5):556.[doi:DOI:10.3969/j.issn.1005-202X.2019.05.012]
 ZHANG Junxi,LIU Zhenxiang,ZHANG Ping,et al. Detection of prostate cancer based on terahertz spectroscopy and imaging[J].Chinese Journal of Medical Physics,2019,36(9):556.[doi:DOI:10.3969/j.issn.1005-202X.2019.05.012]

备注/Memo

备注/Memo:
 【收稿日期】2019-03-11
【基金项目】国家自然科学基金(81472807);四川省卫计委科研项目(16PJ321);四川省科技计划项目(2016JY0072)
【作者简介】张祥斌,硕士研究生,研究方向:肿瘤放射物理,E-mail: rtcheungx@163.com
【通信作者】柏森,主任技师,研究方向:肿瘤放射物理,E-mail:baisen@scu.edu.cn
更新日期/Last Update: 2019-09-23