[1]周军,黄胜,刘崇武,等. 医用加速器输出剂量长期稳定性分析[J].中国医学物理学杂志,2019,36(8):903-907.[doi:DOI:10.3969/j.issn.1005-202X.2019.08.008]
 ZHOU Jun,HUANG Sheng,LIU Chongwu,et al. Long-term stability analysis on output dose of medical accelerator[J].Chinese Journal of Medical Physics,2019,36(8):903-907.[doi:DOI:10.3969/j.issn.1005-202X.2019.08.008]
点击复制

 医用加速器输出剂量长期稳定性分析()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
36卷
期数:
2019年第8期
页码:
903-907
栏目:
医学放射物理
出版日期:
2019-08-26

文章信息/Info

Title:
 Long-term stability analysis on output dose of medical accelerator
文章编号:
1005-202X(2019)08-0903-05
作者:
 周军黄胜刘崇武胡厚胡铭阳何水
 武警四川省总队医院肿瘤科, 四川 乐山 614000
Author(s):
ZHOU Jun HUANG Sheng LIU Chongwu HU Hou HU Mingyang HE Shui
 Department of Radiation Oncology, Sichuan Provincial Corps Hospital of Chinese People’s Armed Police Forces, Leshan 614000, China
关键词:
 医用加速器输出剂量剂量测量稳定性
Keywords:
 Keywords: medical accelerator output dose dose measurement stability
分类号:
R318.6;R811.1
DOI:
DOI:10.3969/j.issn.1005-202X.2019.08.008
文献标志码:
A
摘要:
 目的:分析医用加速器输出剂量长期稳定性及其影响因素。方法:按照IAEA TRS 277技术报告,对武警四川省总队医院医用加速器进行吸收剂量测量,统计分析2012年5月~2017年12月共计240组输出剂量数据,分析医用加速器输出剂量长期稳定性及其影响因素,为加速器剂量质量保证提供方法与措施。结果:6 MV-X输出剂量3组数据K-S检验双尾渐进概率P值分别为0.101、0.269、0.549,均大于显著性水平0.05,符合标准正态分布,且P值逐渐增大,符合程度越来越好;剂量误差≤1%符合率达到91.94%,剂量误差≤2%符合率达到97.92%。结论:武警四川省总队医院医用加速器输出剂量具有很好的正态性和长期稳定性,完全能够满足临床放疗需求;影响加速器输出剂量稳定性的主要因素有加速器硬件自身稳定性、剂量仪电离室稳定性、剂量测量方法准确性、摆位误差等;物理师应按照科室实际情况,制定个体化的加速器剂量质量保证程序,并按照规定频次校准输出剂量,监测输出剂量的稳定性,为精准放疗提供有力保障。
Abstract:
 Abstract: Objective To analyze the long-term stability of the output dose of medical accelerator and discuss its influencing factors. Methods According to IAEA TRS 277 report, the absorbed dose measurement was performed on medical accelerators in Sichuan Provincial Corps Hospital of Chinese People’s Armed Police Forces, and a total of 240 groups of output dose data from May 2012 to December 2017 were statistically analyzed. The long-term stability of the output dose of medical accelerator and its influencing factors were analyzed for providing methods and measures for the dose quality assurance of medical accelerator. Results The K-S test on 3 groups of 6 MV-X output doses showed that two-tailed progressive probability P values ??were 0.101, 0.269, and 0.549, respectively, which were all greater than the significance level of 0.05 and accord with the standard normal distribution. The P value was gradually increased, and the degree of coincidence was also gradually increased. Moreover, the coincidence rates of dose error ≤1% and ≤2% were 91.94% and 97.92%, respectively. Conclusion The output dose of the medical accelerator in Sichuan Provincial Corps Hospital of Chinese People’s Armed Police Forces has good normality and long-term stability, and can fully meet the needs of clinical radiotherapy. The main factors that affect the stability of the output dose of accelerator includes the self stable of accelerator hardware, the stable of dosimeter and ionization chamber, the accuracy of measurement method and setup errors, etc. Physicists should formulate an individualized accelerator dose quality assurance procedure according to the actual situation of the department, and calibrate the output dose according to the specified frequency, and monitor the stability of the output dose, thereby providing a guarantee for precision radiotherapy.

相似文献/References:

[1]徐云,吴章文,侯氢,等.医用加速器光子角分布的蒙特卡罗研究[J].中国医学物理学杂志,2013,30(02):3967.[doi:10.3969/j.issn.1005-202X.2013.02.001]
[2]陈明明,陈颖,陈相宁,等.基于ARM的医用加速器摆位控制系统研制[J].中国医学物理学杂志,2015,32(06):790.[doi:doi:10.3969/j.issn.1005-202X.2015.06.007]
 [J].Chinese Journal of Medical Physics,2015,32(8):790.[doi:doi:10.3969/j.issn.1005-202X.2015.06.007]
[3]王遥,霍万里,熊壮,等.TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较[J].中国医学物理学杂志,2016,33(6):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
 [J].Chinese Journal of Medical Physics,2016,33(8):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
[4]张新,谷晓芳,王培臣,等.轻离子束治疗设备注册检验关键技术问题[J].中国医学物理学杂志,2016,33(6):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
 [J].Chinese Journal of Medical Physics,2016,33(8):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
[5]江芬芬,王培,康盛伟,等. 热释光剂量片测量肺部肿瘤放疗剂量的方法[J].中国医学物理学杂志,2016,33(6):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
 [J].Chinese Journal of Medical Physics,2016,33(8):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
[6]刘洪源,彭威,杨锐,等. 锥形束CT离线校正肺癌摆位误差[J].中国医学物理学杂志,2016,33(6):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
 [J].Chinese Journal of Medical Physics,2016,33(8):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
[7]赵彪,潘香,杨毅,等. 右乳癌保乳术后瘤床同步X线和后程电子线补量调强放疗剂量学比较[J].中国医学物理学杂志,2016,33(6):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
 [J].Chinese Journal of Medical Physics,2016,33(8):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
[8]邓南,钱建庭,刁现芬,等. 基于宽带检测放疗X-光光声效应仿体实验[J].中国医学物理学杂志,2016,33(9):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
 [J].Chinese Journal of Medical Physics,2016,33(8):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
[9]张先稳,李军,张西志,等. 宫颈癌术后5野调强放疗4个变量组合的最佳治疗模式的剂量学[J].中国医学物理学杂志,2016,33(9):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
 [J].Chinese Journal of Medical Physics,2016,33(8):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
[10]胡健,李承军,徐利明,等. 床面倾斜对剂量验证通过率的影响[J].中国医学物理学杂志,2016,33(9):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
 [J].Chinese Journal of Medical Physics,2016,33(8):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]

备注/Memo

备注/Memo:
 【收稿日期】2019-02-01
【基金项目】乐山市重点科研项目(19SZD180)
【作者简介】周军,工程师,研究方向:放射物理、加速器物理与工程,
E-mal: joelchou@126.com