[1]蒋大振,刘晖,戴静,等. 胃癌调强放疗中多叶光栅3种状态的剂量学比较[J].中国医学物理学杂志,2019,36(2):166-170.[doi:DOI:10.3969/j.issn.1005-202X.2019.02.009]
 JIANG Dazhen,LIU Hui,DAI Jing,et al. Dosimetric comparison among split-field, fixed-jaw and rotating multi-leaf collimator in the radiotherapy of gastric carcinoma[J].Chinese Journal of Medical Physics,2019,36(2):166-170.[doi:DOI:10.3969/j.issn.1005-202X.2019.02.009]
点击复制

 胃癌调强放疗中多叶光栅3种状态的剂量学比较()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
36卷
期数:
2019年第2期
页码:
166-170
栏目:
医学放射物理
出版日期:
2019-02-25

文章信息/Info

Title:
 Dosimetric comparison among split-field, fixed-jaw and rotating multi-leaf collimator in the radiotherapy of gastric carcinoma
文章编号:
1005-202X(2019)02-0166-05
作者:
 蒋大振刘晖戴静周福祥谢丛华王骁踊
 武汉大学中南医院肿瘤放化疗科, 湖北 武汉 430071
Author(s):
 JIANG Dazhen LIU Hui DAI Jing ZHOU Fuxiang XIE Conghua WANG Xiaoyong
 Department of Radiation Oncology, Zhongnan Hospital of Wuhan University, Wuhan 430071, China
关键词:
 胃癌多叶光栅锁野计划分野计划调强放射治疗
Keywords:
 Keywords: gastric carcinoma multi-leaf collimator fixed-jaw plan split-field plan intensity-modulated radiotherapy
分类号:
R735.2;R811.1
DOI:
DOI:10.3969/j.issn.1005-202X.2019.02.009
文献标志码:
A
摘要:
 目的:通过比较胃癌调强放疗中多叶光栅(MLC)3种不同状态下放疗计划的剂量学差异,为临床放疗方案的选择提供参考依据。 方法:选取10例胃癌患者分别制定9野的锁野调强、分野调强和旋转小机头分野调强的治疗计划,比较机器跳数,靶区适形度、均匀性、Dmax、Dmean、V45,以及body、肝脏、小肠、脊髓和肾脏V5、V10、V20、V30、V40、V45、Dmax、Dmean等参数的剂量学差异。 结果:3种计划均可满足临床需求。锁野计划相比分野和旋转小机头分野调强计划在body的V5、V10、V20、V30均显著降低且差异具有统计学意义,同时对于肾脏、肝脏和小肠在某些低剂量区均有一定的降低且有统计学差异。对于body(计划靶区)的Dmax参数,分野计划稍微低于锁野和旋转小机头分野调强计划且差异具有统计学意义。 结论:锁野计划可以更好地保护危及器官,同时减少低剂量区。
Abstract:
 Abstract: Objective To compare the dosimetric differences among split-field, fixed-jaw and rotating multi-leaf collimator (RMLC) used in intensity-modulated radiotherapy of gastric carcinoma for providing reference for the selection of treatment strategy. Methods Ten patients with gastric carcinoma was enrolled in this study, and 3 plans, namely fixed-jaw plan (9-field), split-field plan and RMLC plan, were designed for each patient. Several dosimetric parameters, including monitor units, the conformity index, homogeneity index, Dmax, Dmean, V45 of target areas, and the V5, V10, V20, V30, V40, V45, Dmax, Dmean of the body, liver, small intestine, spinal cord and kidneys were compared. Results All 3 plans met clinical requirements. The V5, V10, V20 and V30 of the body in fixed-jaw plan were significantly lower than those in split-field plan and RMLC plan, and meanwhile, there were some decreases in the low-dose volume of the kidney, liver and small intestine, with statistical differences. The Dmax of the body (planning target volume) in split-field plan was lower than that in fixed-jaw plan and RMLC plan, with statistical differences. Conclusion Compared with split-field plan and RMLC plan, fixed-jaw plan achieves a better organs-at-risk protection and reduces low-dose volume.

相似文献/References:

[1]易伟松,刘文强,陆 东,等.高光谱成像结合化学计量学诊断胃癌组织[J].中国医学物理学杂志,2015,32(01):124.[doi:10.3969/j.issn.1005-202X.2015.01.028]
[2]宋威,赵迪,鹿红,等.胃癌术后调强放疗射野角度优化的剂量学[J].中国医学物理学杂志,2015,32(06):815.[doi:doi:10.3969/j.issn.1005-202X.2015.06.012]
 [J].Chinese Journal of Medical Physics,2015,32(2):815.[doi:doi:10.3969/j.issn.1005-202X.2015.06.012]
[3]易伟松,钱辉跃,江厚敏.光纤和显微拉曼光谱结合化学计量学鉴别胃癌组织[J].中国医学物理学杂志,2016,33(2):134.[doi:10.3969/j.issn.1005-202X.2016.02.006]
[4]王遥,霍万里,熊壮,等.TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较[J].中国医学物理学杂志,2016,33(6):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
 [J].Chinese Journal of Medical Physics,2016,33(2):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
[5]张新,谷晓芳,王培臣,等.轻离子束治疗设备注册检验关键技术问题[J].中国医学物理学杂志,2016,33(6):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
 [J].Chinese Journal of Medical Physics,2016,33(2):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
[6]江芬芬,王培,康盛伟,等. 热释光剂量片测量肺部肿瘤放疗剂量的方法[J].中国医学物理学杂志,2016,33(6):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
 [J].Chinese Journal of Medical Physics,2016,33(2):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
[7]刘洪源,彭威,杨锐,等. 锥形束CT离线校正肺癌摆位误差[J].中国医学物理学杂志,2016,33(6):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
 [J].Chinese Journal of Medical Physics,2016,33(2):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
[8]赵彪,潘香,杨毅,等. 右乳癌保乳术后瘤床同步X线和后程电子线补量调强放疗剂量学比较[J].中国医学物理学杂志,2016,33(6):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
 [J].Chinese Journal of Medical Physics,2016,33(2):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
[9]卢晓光,刘细友,郑言宏,等.胃癌术后不同IMRT布野方式对剂量分布的影响[J].中国医学物理学杂志,2016,33(7):664.[doi:10.3969/j.issn.1005-202X.2016.07.004]
[10]邓南,钱建庭,刁现芬,等. 基于宽带检测放疗X-光光声效应仿体实验[J].中国医学物理学杂志,2016,33(9):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
 [J].Chinese Journal of Medical Physics,2016,33(2):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]

备注/Memo

备注/Memo:
 【收稿日期】2018-08-11
【作者简介】蒋大振,硕士,物理师,研究方向:放射治疗质量控制,E-mail: dzjiang@yeah.net
【通信作者】王骁踊,物理师,研究方向:放射治疗质量控制,E-mail: wangxiaoyong@znhospital.cn
更新日期/Last Update: 2019-02-26