[1]欧阳水根,苏群,陶娜,等.CBCT引导下不同体位子宫肿瘤IMRT摆位误差及其外放边界[J].中国医学物理学杂志,2018,35(10):1122-1127.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.002]
 OUYANG Shuigen,SU Qun,TAO Na,et al. Setup errors and margins of CBCT-guided IMRT in different positions for uterine neoplasms[J].Chinese Journal of Medical Physics,2018,35(10):1122-1127.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.002]
点击复制

CBCT引导下不同体位子宫肿瘤IMRT摆位误差及其外放边界()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
35卷
期数:
2018年第10期
页码:
1122-1127
栏目:
医学放射物理
出版日期:
2018-10-25

文章信息/Info

Title:
 Setup errors and margins of CBCT-guided IMRT in different positions for uterine neoplasms
文章编号:
1005-202X(2018)10-1122-06
作者:
 欧阳水根苏群陶娜郭晴刘婷婷刘志强魏玺仪牛瑞军陶发利
 甘肃省肿瘤医院放疗科, 甘肃 兰州 730050
Author(s):
 OUYANG Shuigen SU Qun TAO Na GUO Qing LIU Tingting LIU Zhiqiang WEI Xiyi NIU Ruijun TAO Fali
 Department of Radiation Oncology, Gansu Provincial Cancer Hospital, Lanzhou 730050, China
关键词:
 子宫肿瘤影像引导放射治疗锥形束CT摆位误差外放边界
Keywords:
 uterine neoplasm image-guided radiotherapy cone-beam computer setup error margin
分类号:
R811.1
DOI:
DOI:10.3969/j.issn.1005-202X.2018.10.002
文献标志码:
A
摘要:
 目的:研究在千伏级CBCT引导下,不同体位子宫肿瘤患者调强放射治疗中的摆位误差及靶区的外放边界。 方法:采用医科达直线加速器机载影像系统对251例子宫肿瘤患者接受调强放射治疗前行CBCT扫描,其中仰卧位117例、俯卧位134例。系统自动重建图像并与治疗计划CT图像进行配准,获得俯卧位与仰卧位患者x、y、z方向摆位误差,并分别计算患者临床靶区到计划靶区(PTV)的外放边界。 结果:所有患者共行3 128次扫描,俯卧位1 679次与仰卧位1 449次。x、y、z轴的误差均小于0.3 cm为981次,占31.36%;距离治疗等中心偏差距离小于0.3 cm为415次,占13.27%。考虑摆位误差方向时,俯卧位患者的x、y、z方向上摆位误差分别为(0.109 5±0.380 7)、(-0.035 1±0.569 2)、(0.075 1±0.285 2) cm;仰卧位患者的x、y、z方向上摆位误差分别为(0.001 1±0.303 4)、(0.118 4±0.583 0)、(0.033 2±0.248 0) cm。而考虑摆位误差大小时,俯卧位患者的x、y、z方向上摆位误差分别(0.300 8±0.257 7)、(0.442 8±0.359 2)、(0.227 1±0.188 2) cm;仰卧位患者的x、y、z方向上摆位误差分别为(0.229 3±0.198 6)、(0.470 2±0.364 4)、(0.183 2±0.170 3) cm。俯卧位患者PTV在x、y、z方向分别外放0.540、0.486、0.387 cm;仰卧位患者PTV在x、y、z方向分别外放0.215、0.704、0.257 cm。结论:子宫肿瘤患者仰卧位和俯卧位这两种体位的摆位误差有一定差异,以距离治疗等中心偏差距离小于0.3 cm作为摆位误差校准较适合;俯卧位患者的靶区在x、y、z方向分别外放0.540、0.486、0.387 cm;而仰卧位患者则外放0.215、0.704、0.257 cm。
Abstract:
 Objective To study the setup errors and margins in intensity-modulated radiotherapy guided by kV-cone-beam computed tomography (CBCT) for patients with uterine neoplasms who were in prone or supine position. Methods Before radiotherapy began, Elekta Synergy with on-board imager was used to perform CBCT scans on 251 patients with uterine neoplasms, including 117 patients in supine position and 134 in prone position. The setup errors in left-right (x), superior-inferior (y) and anterior-posterior (z) directions were obtained by the registration between the automatically reconstructed images and the planned CT image. Moreover, the margins of planning target areas were also calculated. Results A total of 3 128 CBCT scans were performed on all patients, including 1 679 scans in prone position and 1 449 scans in supine positions. In 981 scans (31.36%), the error of any axis (x, y, z) was less than 0.3 cm; and in 415 scans (13.27%), the deviation distance from the ioscenter was found to be less than 0.3 cm. When the error direction was considered, the setup errors in x, y and z directions were (0.109 5±0.380 7), (-0.035 1±0.569 2), (0.075 1±0.285 2) cm for prone position, and (0.001 1±0.303 4), (0.118 4±0.583 0), (0.033 2±0.248 0) cm for supine position. When the size of the setup error was considered, the setup errors in x, y and z directions were (0.300 8±0.257 7), (0.442 8±0.359 2), (0.227 1±0.188 2) cm for prone position, and (0.229 3±0.198 6), (0.470 2±0.364 4), (0.183 2±0.170 3) cm for supine position. The margins of planning target area in x, y, z directions were 0.540, 0.486, 0.387 cm for prone position and 0.215, 0.704, 0.257 cm for supine position. Conclusion The setup errors of the patients with uterine neoplasms who are in supine versus prone position have differences. The deviation distance from the ioscenter less than 0.3 cm should be used for the calibration of setup errors. The margins of target areas in x, y, z directions are 0.540, 0.486, 0.387 cm for prone position, and 0.215, 0.704, 0.257 cm for supine position.

相似文献/References:

[1]王遥,霍万里,熊壮,等.TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较[J].中国医学物理学杂志,2016,33(6):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
 [J].Chinese Journal of Medical Physics,2016,33(10):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
[2]张新,谷晓芳,王培臣,等.轻离子束治疗设备注册检验关键技术问题[J].中国医学物理学杂志,2016,33(6):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
 [J].Chinese Journal of Medical Physics,2016,33(10):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
[3]江芬芬,王培,康盛伟,等. 热释光剂量片测量肺部肿瘤放疗剂量的方法[J].中国医学物理学杂志,2016,33(6):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
 [J].Chinese Journal of Medical Physics,2016,33(10):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
[4]刘洪源,彭威,杨锐,等. 锥形束CT离线校正肺癌摆位误差[J].中国医学物理学杂志,2016,33(6):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
 [J].Chinese Journal of Medical Physics,2016,33(10):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
[5]赵彪,潘香,杨毅,等. 右乳癌保乳术后瘤床同步X线和后程电子线补量调强放疗剂量学比较[J].中国医学物理学杂志,2016,33(6):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
 [J].Chinese Journal of Medical Physics,2016,33(10):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
[6]邓南,钱建庭,刁现芬,等. 基于宽带检测放疗X-光光声效应仿体实验[J].中国医学物理学杂志,2016,33(9):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
 [J].Chinese Journal of Medical Physics,2016,33(10):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
[7]张先稳,李军,张西志,等. 宫颈癌术后5野调强放疗4个变量组合的最佳治疗模式的剂量学[J].中国医学物理学杂志,2016,33(9):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
 [J].Chinese Journal of Medical Physics,2016,33(10):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
[8]胡健,李承军,徐利明,等. 床面倾斜对剂量验证通过率的影响[J].中国医学物理学杂志,2016,33(9):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
 [J].Chinese Journal of Medical Physics,2016,33(10):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
[9]陈亚正,肖明勇,孙春堂,等. 准直器角度对宫颈癌术后VMAT计划的影响[J].中国医学物理学杂志,2016,33(9):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
 [J].Chinese Journal of Medical Physics,2016,33(10):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
[10]李毅,唐丰文,张晓智. 基于四维CT和锥形束CT确定非小细胞肺癌放疗靶区外放边界[J].中国医学物理学杂志,2016,33(9):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]
 [J].Chinese Journal of Medical Physics,2016,33(10):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]

备注/Memo

备注/Memo:
 【收稿日期】2018-04-22
【基金项目】甘肃省卫生行业科研计划(GSWSKY-2015-29)
【作者简介】欧阳水根,副主医师,从事肿瘤放射物理,E-mail: ouyang328@126.com
更新日期/Last Update: 2018-10-22