[1]史玉静,李金凯,鞠孟阳,等. 肺部肿瘤在放疗分次间随呼吸模式变化的研究[J].中国医学物理学杂志,2018,35(5):509-513.[doi:DOI:10.3969/j.issn.1005-202X.2018.05.003]
 SHI Yujing,LI Jinkai,JU Mengyang,et al. Displacements of pulmonary tumors with the changes of respiratory patterns in fractionated radiotherapy[J].Chinese Journal of Medical Physics,2018,35(5):509-513.[doi:DOI:10.3969/j.issn.1005-202X.2018.05.003]
点击复制

 肺部肿瘤在放疗分次间随呼吸模式变化的研究()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
35卷
期数:
2018年第5期
页码:
509-513
栏目:
医学放射物理
出版日期:
2018-05-22

文章信息/Info

Title:
 Displacements of pulmonary tumors with the changes of respiratory patterns in fractionated radiotherapy
文章编号:
1005-202X(2018)05-0509-05
作者:
 史玉静1李金凯2鞠孟阳1郑海伦2孙新臣2
 1.南京医科大学特种医学系, 江苏 南京 210009; 2.南京医科大学第一附属医院放疗科, 江苏 南京 210009
Author(s):
 SHI Yujing1 LI Jinkai2 JU Mengyang1 ZHENG Hailun2 SUN Xinchen2
 1. Department of Special Medicine, Nanjing Medical University, Nanjing 210009, China; 2. Department of Radiation Oncology, the First Affiliated Hospital of Nanjing Medical University, Nanjing 210009, China
关键词:
 肺部肿瘤 四维CBCT呼吸时相呼吸模式呼吸运动范围
Keywords:
 pulmonary tumor four-dimensional cone beam computed tomography respiratory phase respiratory pattern range of respiratory motion
分类号:
【收稿日期】2018-01-22
DOI:
DOI:10.3969/j.issn.1005-202X.2018.05.003
文献标志码:
A
摘要:
 目的:基于四维(4D)CBCT探讨肺部肿瘤在放疗中呼吸运动模式的变化规律。 方法:收集25例患者的4DCT及125次CBCT图像,通过双匹配(Clipbox 和Mask)功能匹配CBCT图像和计划CT图像。取CBCT图像中的每次图像上吸气与呼气所占时间权重的比值变化表示呼吸模式的变化,取Mask配准时的极值之差表示呼吸运动范围的变化。 结果:随着治疗分次进展,吸气呼气时相所占时间权重比均值为1.10±0.12,且变化与治疗分次及不同患者之间存在相关(F=3.890, P=0.000),吸气相与呼气相所占的时间权重:吸气相为(52±3)%,呼气相为(47±3)%。肿瘤相对位移在各方向的变化为X:0.20 cm,Y:0.39 cm,Z:0.19 cm,且在Y方向具有显著差异(F=2.070, P=0.040)。呼吸运动范围的变化与肿瘤的位移变化是一致的:头脚方向大于其他方向。呼吸运动范围与治疗分次不明显相关(F=0.498, P=0.790),与呼吸运动范围变化相关的是肿瘤大小(r=0.720, P=0.000)及肿瘤位置(r=0.360, P=0.018)。 结论:4DCBCT实时监测引导的PTV外放合理,对于呼吸运动幅度较大及肿瘤相对位移变化较大的患者价值更大。呼吸模式的变化对靶区外扩的影响较大,计划制定及治疗应依据呼吸模式变化进行。
Abstract:
 Objective To evaluate the displacements and motions of pulmonary tumors with the changes of respiratory patterns in radiotherapy by four-dimensional cone beam computed tomography (4DCBCT). Methods 4DCT images and 125 CBCT images were collected from 25 patients. Image matching between CBCT images and planning CT images was carried out with the use of dual registration (Clipbox and Mask). The change of respiratory patterns was defined as the change of the ratio of time spent in inspiration versus time spent in expiration, I/E ratio, in each CBCT image, and the difference between extrema in Mask registration was used to indicate the changes of the range of respiratory motion. Results With the progression of fractionated treatment, the mean I/E ratio was 1.10±0.12, and the change was related to the treatment fraction and different patients (F=3.890, P=0.000). The time weight of inspiratory phase and expiratory phase was (52±3)% and (47±3)%, respectively. The relative displacements of tumors were 0.20, 0.39 and 0.19 cm in X, Y and Z directions, respectively, and the deviation in Y direction had statistical significance (F=2.070, P=0.040). The changes of the range of respiration motion were consistent with the displacements of tumors: the changes in superior-inferior direction were always larger than those in the other directions. The changes of the range of respiratory motion was not significantly related to radiotherapy fractions (F=0.498, P=0.790) but was found to be related to the size and location of tumor (r=0.720, P=0.000; r=0.360, P=0.018). Conclusion Real-time 4DCBCT-guided radiotherapy is suitable for those patients who have large respiratory motions and who have considerable tumor displacements. The change of respiratory patterns affects the internal target volume so effectively that physicists should design plans based on the respiratory patterns.

相似文献/References:

[1]王遥,霍万里,熊壮,等.TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较[J].中国医学物理学杂志,2016,33(6):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
 [J].Chinese Journal of Medical Physics,2016,33(5):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
[2]张新,谷晓芳,王培臣,等.轻离子束治疗设备注册检验关键技术问题[J].中国医学物理学杂志,2016,33(6):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
 [J].Chinese Journal of Medical Physics,2016,33(5):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
[3]刘洪源,彭威,杨锐,等. 锥形束CT离线校正肺癌摆位误差[J].中国医学物理学杂志,2016,33(6):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
 [J].Chinese Journal of Medical Physics,2016,33(5):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
[4]赵彪,潘香,杨毅,等. 右乳癌保乳术后瘤床同步X线和后程电子线补量调强放疗剂量学比较[J].中国医学物理学杂志,2016,33(6):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
 [J].Chinese Journal of Medical Physics,2016,33(5):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
[5]邓南,钱建庭,刁现芬,等. 基于宽带检测放疗X-光光声效应仿体实验[J].中国医学物理学杂志,2016,33(9):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
 [J].Chinese Journal of Medical Physics,2016,33(5):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
[6]张先稳,李军,张西志,等. 宫颈癌术后5野调强放疗4个变量组合的最佳治疗模式的剂量学[J].中国医学物理学杂志,2016,33(9):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
 [J].Chinese Journal of Medical Physics,2016,33(5):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
[7]胡健,李承军,徐利明,等. 床面倾斜对剂量验证通过率的影响[J].中国医学物理学杂志,2016,33(9):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
 [J].Chinese Journal of Medical Physics,2016,33(5):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
[8]陈亚正,肖明勇,孙春堂,等. 准直器角度对宫颈癌术后VMAT计划的影响[J].中国医学物理学杂志,2016,33(9):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
 [J].Chinese Journal of Medical Physics,2016,33(5):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
[9]李毅,唐丰文,张晓智. 基于四维CT和锥形束CT确定非小细胞肺癌放疗靶区外放边界[J].中国医学物理学杂志,2016,33(9):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]
 [J].Chinese Journal of Medical Physics,2016,33(5):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]
[10]王贝,全红,邱杰,等. 容积旋转调强技术用于直肠癌时最佳机架角度设置研究[J].中国医学物理学杂志,2016,33(9):898.[doi:10.3969/j.issn.1005-202X.2016.09.006]
 [J].Chinese Journal of Medical Physics,2016,33(5):898.[doi:10.3969/j.issn.1005-202X.2016.09.006]
[11]江芬芬,王培,康盛伟,等. 热释光剂量片测量肺部肿瘤放疗剂量的方法[J].中国医学物理学杂志,2016,33(6):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
 [J].Chinese Journal of Medical Physics,2016,33(5):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
[12]宋孟孟,王运来,黄祥,等. 肺部肿瘤基于最大密度投影图像和四维CT勾画的内靶区差异性分析[J].中国医学物理学杂志,2018,35(2):135.[doi:DOI:10.3969/j.issn.1005-202X.2018.02.003]
 SONG Mengmeng,WANG Yunlai,HUANG Xiang,et al. Differences of internal target areas delineated from maximum intensity projection image versus four-dimensional computed tomography image of lung tumor[J].Chinese Journal of Medical Physics,2018,35(5):135.[doi:DOI:10.3969/j.issn.1005-202X.2018.02.003]

备注/Memo

备注/Memo:
 【收稿日期】2018-01-22
【基金项目】国家自然科学基金(81472809,81502653,81672983,81703028)
【作者简介】史玉静,硕士研究生,研究方向:放射物理学,E-mail:1208519910@qq.com;李金凯,硕士,主管技师,研究方向:放射物理学,E-mail:ljinkai1028@163.com
【通信作者】孙新臣,博士,主任医师,研究方向:肿瘤放射治疗学与放射生物学,E-mail:sunxinchen123@hotmail.com
更新日期/Last Update: 2018-05-22