[1]牛振洋,费振乐,陈志. Octavius 4D系统稳定性验证分析[J].中国医学物理学杂志,2018,35(6):628-632.[doi:DOI:10.3969/j.issn.1005-202X.2018.06.002]
 NIU Zhenyang,FEI Zhenle,CHEN Zhi. Stability analysis of Octavius 4D system[J].Chinese Journal of Medical Physics,2018,35(6):628-632.[doi:DOI:10.3969/j.issn.1005-202X.2018.06.002]
点击复制

 Octavius 4D系统稳定性验证分析()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
35卷
期数:
2018年第6期
页码:
628-632
栏目:
医学放射物理
出版日期:
2018-06-22

文章信息/Info

Title:
 Stability analysis of Octavius 4D system
文章编号:
1005-202X(2018)06-0628-05
作者:
 牛振洋12费振乐2陈志1
 1.中国科学技术大学, 安徽 合肥 230027; 2.中国人民解放军第105医院, 安徽 合肥 230031
Author(s):
 NIU Zhenyang12 FEI Zhenle2 CHEN Zhi1
1. University of Science and Technology of China, Hefei 230027, China; 2. the 105 Hospital of the Chinese People’s Liberation Army, Hefei 230031, China
关键词:
 Octavius 4D系统容积旋转调强放射治疗探测器阵列γ通过率稳定性
Keywords:
 Octavius 4D system volumetric modulated arc therapy detector array gamma passing rate stability
分类号:
R312
DOI:
DOI:10.3969/j.issn.1005-202X.2018.06.002
文献标志码:
A
摘要:
 目的:探讨Octavius 4D系统用于容积旋转调强放射治疗(VMAT)三维剂量验证的稳定性。 方法:比较分析semiflex电离室和Octavius 729探测器阵列在6 MV、10 MV射束下对射野大小、剂量线性、剂量率线性和射野输出因子的响应。测量观察Octavius 4D系统旋转过程中角度仪示值与机架角的角度偏差。用3 %/3 mm标准分析(10×10) cm2 旋转照射计划和VMAT计划机架归零与旋转照射的二维剂量分布;用3%/3 mm gamma分析标准评估VMAT计划。 结果:预热剂量大于6 Gy是探测器稳定的必要条件。探测器阵列剂量响应是线性的,不同标称剂量率下剂量测量是稳定的。旋转照射过程中加速器机架角和Octavius 4D模体旋转角度误差在0.4°以内。6 MV和10 MV射束VMAT计划在分析标准为3%/3 mm时,三维剂量分布的平均通过率分别为96.03%和95.56%,满足临床计划剂量验证的标准。 结论:Octavius 4D模体联合Octavius 729探测器阵列是一套稳定性装置,用于治疗前验证VMAT计划是可靠的。
Abstract:
 Objective To explore the stability of Octavius 4D system in the three-dimensional dose verification of volumetric modulated arc therapy (VMAT). Methods The responses of semiflex ionization chamber and Octavius 729 detector array to field size, dose linearity, dose rate linearity and output factors were assessed for 6 MV and 10 MV beams. When Octavius 4D system was running, the angular deviations between inclinometer and gantry were measured. With gantry in rotating state or fixed at 0°, the two-dimensional dose distributions of (10×10) cm2 arc plans and VMAT plans were analyzed with 3%/3 mm criteria. VMAT plans were assessed by 3%/3 mm gamma analysis standard. Results A warm-up dose larger than 6 Gy was essential for detector stability. Dose response of detector array was linear, and dose-rate measurements were stable at different nominal dose rates. During rotating irradiation, the angular deviation of accelerator gantry angle and rotation angle of Octavius 4D phantom was found to be within 0.4°. When 3%/3 mm criteria was applied, the average gamma passing rate of three-dimensional dose distribution were 96.03% and 95.56% for VMAT plan with 6 MV or 10 MV beams. Conclusion Octavius 4D phantom combined with Octavius 729 detector array is a stable device and is reliable for pretreatment verification of VMAT.

相似文献/References:

[1]王遥,霍万里,熊壮,等.TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较[J].中国医学物理学杂志,2016,33(6):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
 [J].Chinese Journal of Medical Physics,2016,33(6):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
[2]张新,谷晓芳,王培臣,等.轻离子束治疗设备注册检验关键技术问题[J].中国医学物理学杂志,2016,33(6):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
 [J].Chinese Journal of Medical Physics,2016,33(6):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
[3]江芬芬,王培,康盛伟,等. 热释光剂量片测量肺部肿瘤放疗剂量的方法[J].中国医学物理学杂志,2016,33(6):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
 [J].Chinese Journal of Medical Physics,2016,33(6):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
[4]刘洪源,彭威,杨锐,等. 锥形束CT离线校正肺癌摆位误差[J].中国医学物理学杂志,2016,33(6):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
 [J].Chinese Journal of Medical Physics,2016,33(6):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
[5]赵彪,潘香,杨毅,等. 右乳癌保乳术后瘤床同步X线和后程电子线补量调强放疗剂量学比较[J].中国医学物理学杂志,2016,33(6):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
 [J].Chinese Journal of Medical Physics,2016,33(6):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
[6]邓南,钱建庭,刁现芬,等. 基于宽带检测放疗X-光光声效应仿体实验[J].中国医学物理学杂志,2016,33(9):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
 [J].Chinese Journal of Medical Physics,2016,33(6):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
[7]张先稳,李军,张西志,等. 宫颈癌术后5野调强放疗4个变量组合的最佳治疗模式的剂量学[J].中国医学物理学杂志,2016,33(9):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
 [J].Chinese Journal of Medical Physics,2016,33(6):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
[8]胡健,李承军,徐利明,等. 床面倾斜对剂量验证通过率的影响[J].中国医学物理学杂志,2016,33(9):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
 [J].Chinese Journal of Medical Physics,2016,33(6):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
[9]陈亚正,肖明勇,孙春堂,等. 准直器角度对宫颈癌术后VMAT计划的影响[J].中国医学物理学杂志,2016,33(9):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
 [J].Chinese Journal of Medical Physics,2016,33(6):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
[10]李毅,唐丰文,张晓智. 基于四维CT和锥形束CT确定非小细胞肺癌放疗靶区外放边界[J].中国医学物理学杂志,2016,33(9):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]
 [J].Chinese Journal of Medical Physics,2016,33(6):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]

备注/Memo

备注/Memo:
 【收稿日期】2017-12-25
【基金项目】国家重点研发计划(2017YFC0107504)
【作者简介】牛振洋,工程师,主要从事放射物理工作,E-mail: nzy105yy@163.com
【通信作者】陈志,副教授,研究方向:辐射防护,E-mail: zchen@ustc.edu.cn
更新日期/Last Update: 2018-06-22