[1]黄远聪.基于LabVIEW的眼结膜微血管采集管理系统及应用[J].中国医学物理学杂志,2023,40(8):964-970.[doi:DOI:10.3969/j.issn.1005-202X.2023.08.007]
 HUANG Yuancong.Conjunctival microvascular image acquisition and management system based on LabVIEW and its application[J].Chinese Journal of Medical Physics,2023,40(8):964-970.[doi:DOI:10.3969/j.issn.1005-202X.2023.08.007]
点击复制

基于LabVIEW的眼结膜微血管采集管理系统及应用()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
40卷
期数:
2023年第8期
页码:
964-970
栏目:
医学影像物理
出版日期:
2023-09-01

文章信息/Info

Title:
Conjunctival microvascular image acquisition and management system based on LabVIEW and its application
文章编号:
1005-202X(2023)08-0964-07
作者:
黄远聪
中山大学中山眼科中心, 广东 广州 510000
Author(s):
HUANG Yuancong
Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou 510000, China
关键词:
眼结膜微血管LabVIEW图像采集数据管理图像优化
Keywords:
Keywords: conjunctival microvessel LabVIEW image acquisition data management image optimization
分类号:
R318;R770.41
DOI:
DOI:10.3969/j.issn.1005-202X.2023.08.007
文献标志码:
A
摘要:
目的:建立全自动的眼结膜微血管采集管理系统以提高眼结膜微血管临床研究效率。方法:基于LabVIEW软件,自主设计一套眼结膜微血管采集管理系统,实现眼结膜微血管图像自动化采集;然后通过特征设计优化图像质量,最后建立规范化数据管理系统。本研究纳入10例正常人采集眼结膜微血管图像以验证该系统眼结膜微血管成像效率和价值。结果:10例正常人的眼结膜微血管图像的平均采集时间由23 min缩减为10 min,同时经过系统优化提升了图像质量,分析得出的眼结膜微血管参数趋于稳定。图像数据实现了可溯源和保存规范化。结论:经过实验验证,眼结膜微血管采集管理系统实现了眼结膜微血管图像快速、自动化采集和管理,有助于提高眼结膜微血管影像在临床的应用和研究价值。
Abstract:
Abstract: Objective To establish an automatic conjunctival microvascular image acquisition and management system for improving the efficiency of clinical research on conjunctival microvessel. Methods In LabVIEW environment, a set of conjunctival microvascular image acquisition and management system was developed independently to realize automatic image acquisition and optimize image quality through feature design, and finally, a standardized data management system is established. The conjunctival microvascular images collected from 10 healthy subjects were used to verify the efficiency and value of the system. Results The average acquisition time of the conjunctival microvascular images in 10 healthy subjects was reduced from 23 min to 10 min. After system optimization, the image quality was improved, and the microvascular parameters became more stable. The traceability of image data and the standardization of data storage were also realized. Conclusion The conjunctival microvascular image acquisition and management system realizes the rapid and automatic acquisition and management of conjunctival microvascular images, which will help to improve the clinical application and research value of conjunctival microvascular images.

相似文献/References:

[1]谭志向,张 懿,敬 李,等.基于MyDAQ和LabVIEW的胎心音实验系统[J].中国医学物理学杂志,2014,31(02):4782.[doi:10.3969/j.issn.1005-202X.2014.02.015]
[2]查悦明,张刚平,周 平,等.基于虚拟仪器的智能视觉识别机械手系统[J].中国医学物理学杂志,2014,31(02):4806.[doi:10.3969/j.issn.1005-202X.2014.02.020]
[3]李殿立,周宇,游国鹏,等.大功率射频电流环境下的温度测量系统[J].中国医学物理学杂志,2013,30(05):4417.[doi:10.3969/j.issn.1005-202X.2013.05.018]
[4]梁思,董涛,王慧,等.一种基于功能磁共振的味觉刺激装置的设计与验证[J].中国医学物理学杂志,2016,33(1):76.[doi:10.3969/j.issn.1005-202X.2016.01.017]
[5]周平,傅洪波,黄耀熊.基于LabVIEW的数据实时采集与预处理系统[J].中国医学物理学杂志,2016,33(6):626.[doi:10.3969/j.issn.1005-202X.2016.06.018]
 [J].Chinese Journal of Medical Physics,2016,33(8):626.[doi:10.3969/j.issn.1005-202X.2016.06.018]
[6]阮轶磊,李刚,陈财森.基于LabVIEW的X射线机电源电阻测量设计[J].中国医学物理学杂志,2022,39(5):585.[doi:DOI:10.3969/j.issn.1005-202X.2022.05.011]
 RUAN Yilei,LI Gang,CHEN Caisen.Power supply resistance measurement design for X-ray machine based on LabVIEW[J].Chinese Journal of Medical Physics,2022,39(8):585.[doi:DOI:10.3969/j.issn.1005-202X.2022.05.011]
[7]吴林,解玺洁,胡霞飞,等.磁共振空间定位成像的实现与验证[J].中国医学物理学杂志,2022,39(10):1225.[doi:DOI:10.3969/j.issn.1005-202X.2022.10.008]
 WU Lin,XIE Xijie,et al.Implementation and verification of magnetic resonance spatial positioning imaging[J].Chinese Journal of Medical Physics,2022,39(8):1225.[doi:DOI:10.3969/j.issn.1005-202X.2022.10.008]
[8]吴林,胡霞飞,解玺洁,等.磁共振序列同步执行的研究与实现[J].中国医学物理学杂志,2022,39(11):1355.[doi:DOI:10.3969/j.issn.1005-202X.2022.11.007]
 WU Lin,HU Xiafei,et al.Synchronous execution of magnetic resonance sequences and its implementation[J].Chinese Journal of Medical Physics,2022,39(8):1355.[doi:DOI:10.3969/j.issn.1005-202X.2022.11.007]

备注/Memo

备注/Memo:
【收稿日期】2022-11-03 【基金项目】国家自然科学基金(81670826) 【作者简介】黄远聪,初级工程师,研究方向:眼科成像设备,E-mail: huangyuancong@gzzoc.com
更新日期/Last Update: 2023-09-06