[1]杨晶,刘洪源,柳刚,等. 基于肺部模体研究处方等剂量线对射波刀计划质量的影响[J].中国医学物理学杂志,2019,36(10):1125-1128.[doi:DOI:10.3969/j.issn.1005-202X.2019.10.002]
 YANG Jing,LIU Hongyuan,LIU Gang,et al. Lung phantom-based study on the effect of prescription isodose line on CyberKnife plan quality[J].Chinese Journal of Medical Physics,2019,36(10):1125-1128.[doi:DOI:10.3969/j.issn.1005-202X.2019.10.002]
点击复制

 基于肺部模体研究处方等剂量线对射波刀计划质量的影响()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
36卷
期数:
2019年第10期
页码:
1125-1128
栏目:
医学放射物理
出版日期:
2019-10-29

文章信息/Info

Title:
 Lung phantom-based study on the effect of prescription isodose line on CyberKnife plan quality
文章编号:
1005-202X(2019)10-1125-04
作者:
 杨晶刘洪源柳刚聂鑫杨志勇韩军李勤张盛梁志文
 华中科技大学同济医学院附属协和医院肿瘤中心,湖北 武汉 430022
Author(s):
 YANG Jing LIU Hongyuan LIU Gang NIE Xin YANG Zhiyong HAN Jun LI Qin ZHANG Sheng LIANG Zhiwen
 Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
关键词:
 肺部模体射波刀计划处方等剂量线蒙特卡罗算法
Keywords:
 Keywords: lung phantom CyberKnife plan prescription isodose line Monte Carlo algorithm
分类号:
R312;R815
DOI:
DOI:10.3969/j.issn.1005-202X.2019.10.002
文献标志码:
A
摘要:
 目的:基于仿真肺部模体研究不同处方等剂量线(PIDL)的选取对射波刀计划质量的影响。方法:以仿真肺部模体中球方中心球体外扩3 mm作为靶区,体积13.46 cc,设置3个剂量限值壳层,分别距离靶区表面2、15和25 mm。按照已制定的方案优化计划,在靶区处方覆盖率大于98%的情况下获得不同PIDL计划。结果:采用蒙特卡罗算法计算剂量获得40%~73% PIDL计划,其中剂量梯度指数、均匀性指数和V25与PIDL相关系数分别为0.960(P<0.01)、-1.000(P<0.01)和0.673(P=0.033),其它参数与PIDL的相关性无统计学意义。结论:肺部模体的射波刀计划参数中剂量梯度指数、均匀性指数和V25与PIDL显著性相关。50%左右PIDL计划具有较陡峭剂量跌落梯度,同时较高或较低PIDL计划可能导致靶区剂量适形性下降。
Abstract:
 Abstract: Objective To study the effects of prescription isodose line (PIDL) on the quality of CyberKnife plans designed on anthropomorphic lung phantom. Methods The spherical center sphere in anthropomorphic lung phantom was expanded 3 mm and selected as the target area, with a volume of 13.46 cc. Three dose-limit shells were set to be 2, 15 and 25 mm from the target surface, respectively. The plans were optimized according to predesigned strategy, and the plans of different PIDL were obtained under the condition that the prescription coverage of target area was above 98%. Results Monte Carlo algorithm for dose calculation was used to obtain the plans of 40% to 73% PIDL, in which the correlation coefficients of dose gradient index, homogeneity index and V25 with PIDL were 0.960 (P<0.01), -1.000 (P<0.01) and 0.673 (P=0.033), respectively. There was no statistically significant correlation between other parameters and PIDL. Conclusion Among the parameters of CyberKnife plans designed on lung phantom, dose gradient index, homogeneity index and V25 were significantly correlated with PIDL. The plan of about 50% PIDL has a sharper dose falloff gradient, and the plan of higher or lower PIDL may lead to a decreased dose conformity in target areas.

相似文献/References:

[1]王遥,霍万里,熊壮,等.TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较[J].中国医学物理学杂志,2016,33(6):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
 [J].Chinese Journal of Medical Physics,2016,33(10):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
[2]张新,谷晓芳,王培臣,等.轻离子束治疗设备注册检验关键技术问题[J].中国医学物理学杂志,2016,33(6):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
 [J].Chinese Journal of Medical Physics,2016,33(10):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
[3]江芬芬,王培,康盛伟,等. 热释光剂量片测量肺部肿瘤放疗剂量的方法[J].中国医学物理学杂志,2016,33(6):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
 [J].Chinese Journal of Medical Physics,2016,33(10):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
[4]刘洪源,彭威,杨锐,等. 锥形束CT离线校正肺癌摆位误差[J].中国医学物理学杂志,2016,33(6):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
 [J].Chinese Journal of Medical Physics,2016,33(10):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
[5]赵彪,潘香,杨毅,等. 右乳癌保乳术后瘤床同步X线和后程电子线补量调强放疗剂量学比较[J].中国医学物理学杂志,2016,33(6):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
 [J].Chinese Journal of Medical Physics,2016,33(10):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
[6]邓南,钱建庭,刁现芬,等. 基于宽带检测放疗X-光光声效应仿体实验[J].中国医学物理学杂志,2016,33(9):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
 [J].Chinese Journal of Medical Physics,2016,33(10):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
[7]张先稳,李军,张西志,等. 宫颈癌术后5野调强放疗4个变量组合的最佳治疗模式的剂量学[J].中国医学物理学杂志,2016,33(9):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
 [J].Chinese Journal of Medical Physics,2016,33(10):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
[8]胡健,李承军,徐利明,等. 床面倾斜对剂量验证通过率的影响[J].中国医学物理学杂志,2016,33(9):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
 [J].Chinese Journal of Medical Physics,2016,33(10):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
[9]陈亚正,肖明勇,孙春堂,等. 准直器角度对宫颈癌术后VMAT计划的影响[J].中国医学物理学杂志,2016,33(9):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
 [J].Chinese Journal of Medical Physics,2016,33(10):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
[10]李毅,唐丰文,张晓智. 基于四维CT和锥形束CT确定非小细胞肺癌放疗靶区外放边界[J].中国医学物理学杂志,2016,33(9):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]
 [J].Chinese Journal of Medical Physics,2016,33(10):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]

备注/Memo

备注/Memo:
 【收稿日期】2019-04-16
【基金项目】国家重点研发计划(2016YFC0106700);华中科技大学同济医学院附属协和医院院内科学研究(02.03.2018-131)
【作者简介】杨晶,博士,主管技师,研究方向:放射治疗技术,E-mail:jingy200@163.com
更新日期/Last Update: 2019-10-29