[1]蒋晓兰,尹静,周礼平.320排螺旋CT不同时相选择方式对冠状动脉综合征的诊断价值[J].中国医学物理学杂志,2026,43(9):1196-1200.[doi:DOI:10.3969/j.issn.1005-202X.2026.09.006]
 JIANG Xiaolan,YIN Jing,ZHOU Liping.Diagnostic value of different phase selection strategies of 320-row spiral CT in coronary syndrome[J].Chinese Journal of Medical Physics,2026,43(9):1196-1200.[doi:DOI:10.3969/j.issn.1005-202X.2026.09.006]
点击复制

320排螺旋CT不同时相选择方式对冠状动脉综合征的诊断价值()

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
43卷
期数:
2026年第9期
页码:
1196-1200
栏目:
医学影像物理
出版日期:
2026-09-30

文章信息/Info

Title:
Diagnostic value of different phase selection strategies of 320-row spiral CT in coronary syndrome
文章编号:
1005-202X(2026)09-1196-05
作者:
蒋晓兰1; 尹静2; 周礼平1
1.四川省中西医结合医院放射科, 四川 成都 610041;2.四川省中西医结合医院泌尿外科, 四川 成都 610041
Author(s):
JIANG Xiaolan1;  YIN Jing2;  ZHOU Liping1
1. Department of Radiology, Sichuan Integrative Medicine Hospital, Chengdu 610041, China 2. Department of Urology, Sichuan Integrative Medicine Hospital, Chengdu 610041, China
关键词:
螺旋CT; 时相选择; 冠状动脉综合征; 诊断价值
Keywords:
Keywords: spiral-body CT phase selection coronary syndrome diagnostic value
分类号:
R541.1;R816.2
DOI:
DOI:10.3969/j.issn.1005-202X.2026.09.006
文献标志码:
A
摘要:
目的:探讨320排螺旋CT不同时相选择方式在冠状动脉综合征诊断中的价值。方法:选择2024年6月至2025年4月在四川省中西医结合医院行CT检查的161例冠状动脉综合征患者,分别运用人工选择时相与ePhase自动选择时相进行图像重建。对比两种时相选择方式下主动脉根部各项参数值以及冠状动脉各分支血管评分。结果:ePhase自动选择时相组较人工选择时相组主动脉根部噪声值降低(P<0.05),信噪比、右冠状动脉评分、左冠状动脉主干评分、左前降支评分、左回旋支评分升高(P<0.05)。结论:在320排螺旋CT检查冠状动脉综合征患者的过程中,ePhase自动时相选择重建显著优化图像质量,有助于提升诊断效率。
Abstract:
Abstract: Objective To investigate the value of different phase selection of 320-row spiral CT in the diagnosis of coronary syndrome. Methods A total of 161 patients with coronary syndrome who underwent CT examination at Sichuan Integrative Medicine Hospital from June 2024 to April 2025 were enrolled. Image reconstruction was performed using the manual phase selection and the ePhase automatic phase selection, separately. The parameters of aortic root and the scores of coronary artery branches were compared between the two phase selection strategies. Results Compared with the manual phase selection group, the ePhase automatic phase selection group exhibited a reduced noise value at the aortic root (P<0.05), increased signal-to-noise ratio, and superior scores of the right coronary artery, left main coronary artery, left anterior descending branch, and left circumflex branch (P<0.05). Conclusion During the 320-row spiral CT examination of patients with coronary syndrome, the ePhase automatic phase selection significantly optimizes image quality and improves diagnostic efficiency.

相似文献/References:

[1]梁 健.64排螺旋CT结肠成像技术诊断结直肠疾病的有效性分析[J].中国医学物理学杂志,2015,32(03):447.[doi:10.3969/j.issn.1005-202X.2015.03.033]
[2]沈奕晨,聂生东.锥形束CT与螺旋CT图像配准算法及其在放疗中的应用[J].中国医学物理学杂志,2014,31(05):5151.[doi:10.3969/j.issn.1005-202X.2014.05.013]
[3]刘东旭,周丹,王利峰. 胆囊癌及其病灶局部侵犯的MRI诊断及影像学特征[J].中国医学物理学杂志,2019,36(3):322.[doi:DOI:10.3969/j.issn.1005-202X.2019.03.015]
 LIU Dongxu,ZHOU Dan,WANG Lifeng. MRI features and diagnosis of gallbladder carcinoma and local invasion of gallbladder carcinoma[J].Chinese Journal of Medical Physics,2019,36(9):322.[doi:DOI:10.3969/j.issn.1005-202X.2019.03.015]
[4]何小红,纪久雨,陈英杰.256排螺旋CT鉴别诊断乏脂性肾血管平滑肌脂肪瘤和非透明细胞肾癌的价值分析[J].中国医学物理学杂志,2020,37(12):1520.[doi:DOI:10.3969/j.issn.1005-202X.2020.12.009]
 HE Xiaohong,JI Jiuyu,CHEN Yingjie.Value of 256-slice spiral CT in the differential diagnosis of renal angiomyolipoma with minimal fat and non-clear cell renal cell carcinoma[J].Chinese Journal of Medical Physics,2020,37(9):1520.[doi:DOI:10.3969/j.issn.1005-202X.2020.12.009]
[5]赵德春,余可斌,刘嘉,等.不同心率前后门控CT冠状动脉成像图像质量与辐射剂量的相关性分析[J].中国医学物理学杂志,2024,41(2):185.[doi:DOI:10.3969/j.issn.1005-202X.2024.02.010]
 ZHAO Dechun,YU Kebin,LIU Jia,et al.Correlations between image quality and radiation dose in prospective and retrospective ECG-gated CT coronary angiography in patients with different heart rates[J].Chinese Journal of Medical Physics,2024,41(9):185.[doi:DOI:10.3969/j.issn.1005-202X.2024.02.010]
[6]武月华,张爽,王泽正.螺旋CT及三维重建技术诊断颌面部骨折的价值[J].中国医学物理学杂志,2024,41(11):1357.[doi:DOI:10.3969/j.issn.1005-202X.2024.11.006]
 WU Yuehua,ZHANG Shuang,WANG Zezheng.Diagnostic value of spiral CT and three-dimensional reconstruction in maxillofacial fracture[J].Chinese Journal of Medical Physics,2024,41(9):1357.[doi:DOI:10.3969/j.issn.1005-202X.2024.11.006]
[7]张滔,李兰,但倩,等.螺旋CT三维重建技术评估胫骨远端三平面骨折的价值[J].中国医学物理学杂志,2025,42(11):1445.[doi:DOI:10.3969/j.issn.1005-202X.2025.11.006]
 ZHANG Tao,LI Lan,DAN Qian,et al.Value of spiral CT three-dimensional reconstruction technique in evaluating triplane fractures of the distal tibia[J].Chinese Journal of Medical Physics,2025,42(9):1445.[doi:DOI:10.3969/j.issn.1005-202X.2025.11.006]

备注/Memo

备注/Memo:
【收稿日期】2026-01-14 【基金项目】四川省中医药管理局科研专项(2023MS098) 【作者简介】蒋晓兰,主管技师,研究方向:影像技术,E-mail: 13408067- 116@163.com 【通信作者】周礼平,主任医师,研究方向:影像诊断,E-mail: ZLP710515@163.com
更新日期/Last Update: 2026-09-30