[1]邓永锦,王朝阳,丘敏敏,等.基于平均密度投影影像的心脏表面运动全局模型的构建方法[J].中国医学物理学杂志,2025,42(2):199-207.[doi:DOI:10.3969/j.issn.1005-202X.2025.02.009]
 DENG Yongjin,WANG Zhaoyang,QIU Minmin,et al.Construction of a global model of cardiac surface motion based on average intensity projection image[J].Chinese Journal of Medical Physics,2025,42(2):199-207.[doi:DOI:10.3969/j.issn.1005-202X.2025.02.009]
点击复制

基于平均密度投影影像的心脏表面运动全局模型的构建方法()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
42
期数:
2025年第2期
页码:
199-207
栏目:
医学影像物理
出版日期:
2025-01-20

文章信息/Info

Title:
Construction of a global model of cardiac surface motion based on average intensity projection image
文章编号:
1005-202X(2025)02-0199-09
作者:
邓永锦王朝阳丘敏敏黄剑文
中山大学附属第一医院放射治疗科, 广东 广州 510080
Author(s):
DENG Yongjin WANG Zhaoyang QIU Minmin HUANG Jianwen
Department of Radiation Oncology, the First Affiliated Hospital of Sun Yat-sen University, Guangzhou 510080, China
关键词:
心脏平均密度投影心脏表面运动主要成分分析点云
Keywords:
Keywords: cardiac average intensity projection cardiac surface motion principal component analysis point cloud
分类号:
R318;R563.9
DOI:
DOI:10.3969/j.issn.1005-202X.2025.02.009
文献标志码:
A
摘要:
目的:构建一种基于平均密度投影(AIP)影像的心脏表面运动全局模型。方法:将核磁共振心电触发电影的影像数据分为训练集和测试集,进行模型的构建和验证。在AIP影像表面点云上获取基准点,通过曲面特征法确定各时相表面点云对应点。采用主成分分析算法提取特征信息,建立基准点和对应点间的映射关系,构建从AIP表面点云预测各时相表面点云的模型。结果:测试集上模型对应点预测误差RMSE为(0.209±0.020) mm~(0.841±0.074) mm,而各时相表面点云预测误差欧式距离为(1.399±0.029) mm~(1.658±0.100) mm。结论:本文提出的全局模型准确性较高,可为图像分割和临床治疗提供参考。
Abstract:
Abstract: Objective To construct a global model of cardiac surface motion based on average intensity projection (AIP) image. Methods The cine magnetic resonance imaging data were divided into training set and test set for model construction and validation. The datum points were obtained on the AIP surface point cloud, and the corresponding points of each cardiac phase surface point cloud were found based on surface features. Principal component analysis was used to extract feature information, establish the mapping relationship between the datum points and the corresponding points, and construct a model for predicting each temporal phase surface point cloud from the AIP surface point cloud. Results The RMSE of the model on test set for corresponding point prediction ranged from (0.209±0.020) mm to (0.841±0.074) mm, while the Euclidean distance for each time phase surface point cloud prediction ranged from (1.399±0.029) mm to (1.658±0.100) mm. Conclusion The proposed global model exhibit high accuracy and can provide a reference for image segmentation and clinical treatments.

相似文献/References:

[1]李丹明,孙新臣,张 胜,等.食道癌患者心脏图谱指导下心脏勾画的一致性研究[J].中国医学物理学杂志,2014,31(03):4857.[doi:10.3969/j.issn.1005-202X.2014.03.003]
[2]苏清秀,张 矛,金海国,等.比较调强放射治疗与三维适形放疗治疗中下段食管癌时心脏和冠状动脉的受量[J].中国医学物理学杂志,2014,31(05):5139.[doi:10.3969/j.issn.1005-202X.2014.05.010]
[3]柏晗,等.基于四维CT下胸部肿瘤调强计划中心脏和食道的剂量评估[J].中国医学物理学杂志,2016,33(3):293.[doi:DOI:10.3969/j.issn.1005-202X.2016.03.015]
 [J].Chinese Journal of Medical Physics,2016,33(2):293.[doi:DOI:10.3969/j.issn.1005-202X.2016.03.015]
[4]黄迎松,吴剑.心腔动态重建的迭代替换算法[J].中国医学物理学杂志,2017,34(1):70.[doi:10.3969/j.issn.1005-202X.2017.01.014]
 [J].Chinese Journal of Medical Physics,2017,34(2):70.[doi:10.3969/j.issn.1005-202X.2017.01.014]
[5]佟颖,尹勇,程品晶,等. 形变配准技术在心脏剂量评估中的应用[J].中国医学物理学杂志,2018,35(5):503.[doi:DOI:10.3969/j.issn.1005-202X.2018.05.002]
 TONG Ying,YIN Yong,CHENG Pinjing,et al. Application of deformable image registration in the evaluation of radiation dose to the heart[J].Chinese Journal of Medical Physics,2018,35(2):503.[doi:DOI:10.3969/j.issn.1005-202X.2018.05.002]
[6]安义均,赵彪,余立丹,等. 胸中段食管癌VMAT与IMRT的心脏及其亚结构剂量学比较[J].中国医学物理学杂志,2018,35(6):648.[doi:DOI:10.3969/j.issn.1005-202X.2018.06.006]
 AN Yijun,ZHAO Biao,YU Lidan,et al. Comparison of doses of heart and substructures in VMAT versus IMRT for middle thoracic esophageal cancer[J].Chinese Journal of Medical Physics,2018,35(2):648.[doi:DOI:10.3969/j.issn.1005-202X.2018.06.006]
[7]周博雅,金丹,严琼,等. 超声在心肌致密化不全患者诊断中的应用及其临床价值[J].中国医学物理学杂志,2019,36(9):1045.[doi:DOI:10.3969/j.issn.1005-202X.2019.09.010]
 ZHOU Boya,JIN Dan,YAN Qiong,et al.Application and clinical value of ultrasound in the diagnosis of noncompaction of the ventricular myocardium[J].Chinese Journal of Medical Physics,2019,36(2):1045.[doi:DOI:10.3969/j.issn.1005-202X.2019.09.010]
[8]时飞跃,王敏,秦伟,等.智能放疗云平台自动勾画食管癌患者心脏结构的应用[J].中国医学物理学杂志,2019,36(12):1377.[doi:DOI:10.3969/j.issn.1005-202X.2019.12.003]
 SHI Feiyue,WANG Min,et al.Application of RAIC.OIS in automatic segmentation of the heart in patients with esophageal cancer[J].Chinese Journal of Medical Physics,2019,36(2):1377.[doi:DOI:10.3969/j.issn.1005-202X.2019.12.003]
[9]常艳奎,彭昭,周解平,等.基于U-net的心脏自动勾画模型的临床应用及改进[J].中国医学物理学杂志,2020,37(10):1218.[doi:DOI:10.3969/j.issn.1005-202X.2020.10.002]
 CHANG Yankui,PENG Zhao,ZHOU Jieping,et al.Clinical application and improvement of U-net-based model for automatic segmentation of the heart[J].Chinese Journal of Medical Physics,2020,37(2):1218.[doi:DOI:10.3969/j.issn.1005-202X.2020.10.002]
[10]李侃,杜庆安.乳腺癌改良根治术后调强放疗与常规放疗疗效及对心肺的影响[J].中国医学物理学杂志,2021,38(2):168.[doi:DOI:10.3969/j.issn.1005-202X.2021.02.008]
 LI Kan,DU Qingan.Therapeutic effects of intensity-modulated radiotherapy and conventional radiotherapy on breast cancer after modified radical mastectomy and their effects on the heart and lungs[J].Chinese Journal of Medical Physics,2021,38(2):168.[doi:DOI:10.3969/j.issn.1005-202X.2021.02.008]

备注/Memo

备注/Memo:
【收稿日期】2024-08-16 【基金项目】广东省医学科研基金(A2024011) 【作者简介】邓永锦,工程师,研究方向:放疗剂量的精确性,E-mail: dengyj27@mail.sysu.edu.cn 【通信作者】黄剑文,主管技师,研究方向:放疗定位的精确性,E-mail: huangjw77@mail.sysu.edu.cn
更新日期/Last Update: 2025-01-22