[1]杨阳,杨凯华,崔鹏翔,等.颅脑专用线圈在0~6月龄婴儿颅脑MRI中的图像质量对比分析[J].中国医学物理学杂志,2024,41(8):1015-1020.[doi:DOI:10.3969/j.issn.1005-202X.2024.08.015]
 YANG Yang,YANG Kaihua,CUI Pengxiang,et al.Comparative analysis of image quality in magnetic resonance imaging with dedicated craniocerebral coil in infants aged 0-6 months[J].Chinese Journal of Medical Physics,2024,41(8):1015-1020.[doi:DOI:10.3969/j.issn.1005-202X.2024.08.015]
点击复制

颅脑专用线圈在0~6月龄婴儿颅脑MRI中的图像质量对比分析()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
41卷
期数:
2024年第8期
页码:
1015-1020
栏目:
医学影像物理
出版日期:
2024-08-31

文章信息/Info

Title:
Comparative analysis of image quality in magnetic resonance imaging with dedicated craniocerebral coil in infants aged 0-6 months
文章编号:
1005-202X(2024)08-1015-06
作者:
杨阳杨凯华崔鹏翔时胜利
郑州大学附属儿童医院医学影像科, 河南 郑州 450018
Author(s):
YANG Yang YANG Kaihua CUI Pengxiang SHI Shengli
Department of Medical Imaging, Childrens Hospital Affiliated to Zhengzhou University, Zhengzhou 450018, China
关键词:
颅脑图像质量专用线圈婴儿
Keywords:
Keywords: craniocerebral image quality dedicated coil infant
分类号:
R318
DOI:
DOI:10.3969/j.issn.1005-202X.2024.08.015
文献标志码:
A
摘要:
目的:探讨16通道婴幼儿颅脑专用线圈对0~6月龄婴儿颅脑MRI图像质量的影响。方法:选取32名0~6月龄患儿使用16通道婴幼儿颅脑专用线圈行颅脑MRI检查(专用线圈组),另选取同时期使用常规头颈联合线圈行颅脑MRI检查的32名0~6月龄患儿作为常规线圈组,扫描序列均包含横断位T1加权像(T1WI)、T2加权像(T2WI)、T2液体衰减反转恢复序列(FLAIR)以及横断位弥散加权像(DWI),分别对扫描图像进行主观和客观评价。结果:主观评分中:T1WI、T2WI、FLAIR序列评分均达到4分以上,DWI序列均达到3分以上;在T1WI、T2WI和FLAIR序列中两名评分者评分一致性程度较强(Kappa值分别为0.717、0.652、0.784),在DWI序列中,一致性程度一般(Kappa值为0.321),均具有统计学意义(P<0.05)。客观评价中,专用线圈组各序列的SNR和CNR在颅脑左右叶上均表现出高度的一致性,且颅脑左右叶SNR和CNR差异无统计学意义(P>0.05);相较于常规线圈组,专用线圈组在各个序列SNR、CNR均有所增加,其中在T1WI序列SNR、CNR和DWI序列SNR,两组差异有统计学意义(P<0.05)。结论:使用颅脑专用线圈扫描0~6月龄婴儿颅脑图像可以满足临床需求;专用线圈组图像质量在主、客观评价中均优于常规线圈组。
Abstract:
Objective To investigate the effects of 16-channel dedicated craniocerebral coil on brain magnetic resonance imaging (MRI) image quality in infants aged 0-6 months. Methods Thirty-two infants aged 0-6 months receiving craniocerebral MRI examination with 16-channel dedicated craniocerebral coil were enrolled as observation group, while 32 infant aged 0-6 months receiving craniocerebral MRI examination with conventional head and neck combined coil in the same period were enrolled as control group. The scanning sequences included transverse T1 weighted imaging (T1WI), T2 weighted imaging (T2WI), T2 fluid-attenuated inversion recovery (FLAIR) and diffusion-weighted imaging (DWI) sequences. The scanned images were evaluated subjectively and objectively. Results In the subjective evaluation, T1WI, T2WI and FLAIR sequences scored higher than 4, and DWI sequence scored higher than 3. There were high consistency between two raters for T1WI, T2WI and FLAIR sequences (Kappa value=0.717, 0.652, and 0.784, respectively P<0.05), and moderate consistency for DWI sequence (Kappa value=0.321 P<0.05). In the objective evaluation, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of each sequence in the dedicated coil group were highly consistent in the left and right lobes of the brain, and the differences in the SNR and CNR between the left and right lobes of the brain were trivial (P>0.05). The SNR and CNR of each sequence in the dedicated coil group increased as compared with the conventional coil group, and the differences in the SNR and CNR of T1WI sequence and the SNR of DWI sequence were statistically significant (P<0.05). Conclusion The brain images of infants aged 0-6 months obtained with a dedicated craniocerebral coil can better meet the clinical needs, and the image quality of the dedicated coil group is superior to that of the conventional coil group in both subjective and objective evaluations.

相似文献/References:

[1]张俊,朱金汉,庄永东,等. 基于卷积神经网络CT/CBCT影像质量自动分析[J].中国医学物理学杂志,2018,35(5):557.[doi:DOI:10.3969/j.issn.1005-202X.2018.05.012]
 ZHANG Jun,ZHU Jinhan,ZHUANG Yongdong,et al. Automatic analysis of CT/CBCT image quality based on convolutional neural network[J].Chinese Journal of Medical Physics,2018,35(8):557.[doi:DOI:10.3969/j.issn.1005-202X.2018.05.012]
[2]吴明群,杨聪玲,高红霞. 图像域迭代重建算法对腹部CT平扫图像质量和辐射剂量的影响[J].中国医学物理学杂志,2018,35(10):1169.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.011]
 WU Mingqun,YANG Congling,GAO Hongxia.Effects of iterative reconstruction in image space on the quality of abdominal CT plain scan image and radiation dose[J].Chinese Journal of Medical Physics,2018,35(8):1169.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.011]
[3]蔡冬鹭,蔡思清,颜丽笙,等. 数字乳腺三维断层摄影技术平均腺体剂量与图像质量的关系[J].中国医学物理学杂志,2019,36(10):1187.[doi:DOI:10.3969/j.issn.1005-202X.2019.10.014]
 CAI Donglu,CAI Siqing,YAN Lisheng,et al. Relationship between average glandular dose in digital breast tomosynthesis and image quality[J].Chinese Journal of Medical Physics,2019,36(8):1187.[doi:DOI:10.3969/j.issn.1005-202X.2019.10.014]
[4]任占丽,贺太平,于勇,等.多模型迭代重建在CT门静脉成像中改善图像质量的应用[J].中国医学物理学杂志,2020,37(8):1017.[doi:DOI:10.3969/j.issn.1005-202X.2020.08.015]
 REN Zhanli,HE Taiping,et al.Application of adaptive statistical iterative reconstruction-V technique in CT portal venography for improving image quality[J].Chinese Journal of Medical Physics,2020,37(8):1017.[doi:DOI:10.3969/j.issn.1005-202X.2020.08.015]
[5]薛莹,王瑞,李进丹,等.医学影像仿真人体模型及其临床应用[J].中国医学物理学杂志,2021,38(5):592.[doi:DOI:10.3969/j.issn.1005-202X.2021.05.013]
 XUE Ying,WANG Rui,LI Jindan,et al.Introduction and clinical application of anthropomorphic phantom for medical imaging[J].Chinese Journal of Medical Physics,2021,38(8):592.[doi:DOI:10.3969/j.issn.1005-202X.2021.05.013]
[6]李兰,殷小丹,李旭雪,等.3D MERGE与3D SPACE STIR序列在腰椎间盘突出症检查中的应用比较[J].中国医学物理学杂志,2024,41(1):27.[doi:DOI:10.3969/j.issn.1005-202X.2024.01.004]
 LI Lan,YIN Xiaodan,LI Xuxue,et al.Application of 3D MERGE sequence versus 3D SPACE STIR sequence in the examination of lumbar disc herniation[J].Chinese Journal of Medical Physics,2024,41(8):27.[doi:DOI:10.3969/j.issn.1005-202X.2024.01.004]
[7]高艳,潘小文,董晚亭,等.磁共振脂肪抑制质子密度加权序列诊断骨关节外伤性骨髓水肿的价值[J].中国医学物理学杂志,2024,41(2):181.[doi:DOI:10.3969/j.issn.1005-202X.2024.02.009]
 GAO Yan,PAN Xiaowen,DONG Wanting,et al.Diagnostic value of MRI using proton density-weighted fat-saturated sequence for bone marrow edema in osteoarticular injury[J].Chinese Journal of Medical Physics,2024,41(8):181.[doi:DOI:10.3969/j.issn.1005-202X.2024.02.009]
[8]赵德春,余可斌,刘嘉,等.不同心率前后门控CT冠状动脉成像图像质量与辐射剂量的相关性分析[J].中国医学物理学杂志,2024,41(2):185.[doi:DOI:10.3969/j.issn.1005-202X.2024.02.010]
 ZHAO Dechun,YU Kebin,LIU Jia,et al.Correlations between image quality and radiation dose in prospective and retrospective ECG-gated CT coronary angiography in patients with different heart rates[J].Chinese Journal of Medical Physics,2024,41(8):185.[doi:DOI:10.3969/j.issn.1005-202X.2024.02.010]
[9]戴姗姗,张晓颖,肖鹏飞,等.LightSpeed VCT Console图像升级改造技术的优化方案[J].中国医学物理学杂志,2024,41(6):747.[doi:DOI:10.3969/j.issn.1005-202X.2024.06.013]
 DAI Shanshan,ZHANG Xiaoying,XIAO Pengfei,et al.Optimization scheme of LightSpeed VCT Console image upgrade and transformation technology[J].Chinese Journal of Medical Physics,2024,41(8):747.[doi:DOI:10.3969/j.issn.1005-202X.2024.06.013]
[10]陈宇亭,周飞宇,张富利,等.兆伏级CT图像引导自适应放疗中生成合成CT研究[J].中国医学物理学杂志,2024,41(7):813.[doi:DOI:10.3969/j.issn.1005-202X.2024.07.005]
 CHEN Yuting,ZHOU Feiyu,et al.Generating synthetic CT in megavoltage CT image-guided adaptive radiotherapy[J].Chinese Journal of Medical Physics,2024,41(8):813.[doi:DOI:10.3969/j.issn.1005-202X.2024.07.005]

备注/Memo

备注/Memo:
【收稿日期】2024-01-20 【作者简介】杨阳,技师,研究方向:儿童CT、MR检查技术,E-mail: 804440249@qq.com 【通信作者】杨凯华,副主任技师,研究方向:儿童CT、MR检查技术,E-mail: 588ykh@163.com
更新日期/Last Update: 2024-08-31