[1]李昕,李浩然,郑其斌.粒子放射治疗之束流监测的研究进展[J].中国医学物理学杂志,2024,41(3):273-281.[doi:DOI:10.3969/j.issn.1005-202X.2024.03.002]
 LI Xin,LI Haoran,ZHENG Qibin.Review on beam monitoring for particle radiotherapy[J].Chinese Journal of Medical Physics,2024,41(3):273-281.[doi:DOI:10.3969/j.issn.1005-202X.2024.03.002]
点击复制

粒子放射治疗之束流监测的研究进展()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
41卷
期数:
2024年第3期
页码:
273-281
栏目:
医学放射物理
出版日期:
2024-03-27

文章信息/Info

Title:
Review on beam monitoring for particle radiotherapy
文章编号:
1005-202X(2024)03-0273-09
作者:
李昕李浩然郑其斌
上海理工大学健康科学与工程学院辐射探测与医学成像实验室, 上海 200093
Author(s):
LI Xin LI Haoran ZHENG Qibin
Laboratory of Radiation Detection and Medical Imaging, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
关键词:
粒子治疗质量保证束流监测探测器综述
Keywords:
Keywords: particle therapy quality assurance beam monitoring detector review
分类号:
R318;R815.2
DOI:
DOI:10.3969/j.issn.1005-202X.2024.03.002
文献标志码:
A
摘要:
粒子放射治疗是一种新型的放射治疗方法,具有更好的瞄准性和更高的精度,能进行更精准的放射治疗。然而,粒子束流的复杂性以及每个患者的病变部位和体质不同,为了确保粒子放射治疗的疗效,需要一个高精度的束流监测系统来监测束流的空间和能量分布,如位置和剂量等重要参数。所以束流监测系统对于粒子治疗中的安全性和精准性有着非常重要的作用。通过监测束流的位置和剂量等重要参数,可以实时调整治疗计划,从而确保粒子束流能够准确地照射到病变部位,对周围健康组织的影响降到最低。因此,研制并验证这种束流监测系统是粒子放射治疗中极为重要的一步。本文将综述粒子治疗中质量保证束流监测的发展历程。首先简述粒子放射治疗的发展,重点说明束流监测系统对于粒子放射治疗的重要性。然后着重论述粒子束流监测的发展过程,并介绍不同类型的探测器及其应用和研究进展。最后探讨束流监测系统的未来发展趋势和可能面对的挑战。
Abstract:
Abstract: Particle radiotherapy is a new type of radiotherapy with superior targeting and precision for more accurate radiotherapy. Considering the complexity of the particle beams and the different lesion sites and physique of patients, a high-precision beam monitoring system which enables the monitoring of the spatial and energy distributions of the beams, such as position, dose and other important parameters, is needed to ensure the efficacy of particle radiotherapy. The beam monitoring system plays a crucial role in the safety and accuracy of particle therapy. By monitoring vital parameters such as the position and dose of the beams, the treatment plan can be adjusted in real-time, thus ensuring accurate lesion irradiation while minimizing the effects on the surrounding healthy tissues. Consequently, the development and validation of such a beam monitoring system are essential in particle radiotherapy. Herein the advances in beam monitoring for quality assurance for particle therapy are summarized. It gives a brief description of particle radiotherapy, emphasizing the significance of beam monitoring systems for particle radiotherapy, focuses on the development of particle beam monitoring and introduces different types of detectors, along with their applications and research advancements, and explores the future development trend of beam monitoring system and potential challenges it may face.

相似文献/References:

[1]张富利,王雅棣,许卫东,等.应用两种三维探测器阵列进行螺旋断层调强放疗计划剂量验证[J].中国医学物理学杂志,2015,32(02):218.[doi:10.3969/j.issn.1005-202X.2015.02.015]
[2]张富利,蒋华勇,王雅棣,等.应用一维、二维、三维探测器阵列进行螺旋断层调强放疗计划剂量验证[J].中国医学物理学杂志,2014,31(06):5230.[doi:10.3969/j.issn.1005-202X.2014.06.002]
[3]周永强,金献测,易金玲,等.锥形束CT的验收与QA探讨[J].中国医学物理学杂志,2013,30(01):3854.[doi:10.3969/j.issn.1005-202X.2013.01.005]
[4]刘浩,白靖平,李公平,等.锥形束CT图象引导放疗的应用性测试[J].中国医学物理学杂志,2013,30(01):3877.[doi:10.3969/j.issn.1005-202X.2013.01.010]
[5]徐慧军,李玉,张素静,等.G4射波刀两年质量保证检测结果的回顾与评价[J].中国医学物理学杂志,2013,30(03):4097.[doi:10.3969/j.issn.1005-202X.2013.03.002]
[6]张俊,王昊,谢丛华,等.基于解剖结构的三维剂量验证系统物理模型测试及应用[J].中国医学物理学杂志,2015,32(04):474.[doi:10.3969/j.issn.1005-202X.2015.04.005]
 [J].Chinese Journal of Medical Physics,2015,32(3):474.[doi:10.3969/j.issn.1005-202X.2015.04.005]
[7]谷珊珊,王运来,解传斌,等.电离室矩阵验证近距离治疗中放射源位置的准确性[J].中国医学物理学杂志,2015,32(04):586.[doi:10.3969/j.issn.1005-202X.2015.04.029]
 [J].Chinese Journal of Medical Physics,2015,32(3):586.[doi:10.3969/j.issn.1005-202X.2015.04.029]
[8]石锦平,石俊田,何宝贞,等.容积调强放射治疗多叶准直器质量保证方法[J].中国医学物理学杂志,2015,32(05):724.[doi:doi:10.3969/j.issn.1005-202X.2015.05.025]
 [J].Chinese Journal of Medical Physics,2015,32(3):724.[doi:doi:10.3969/j.issn.1005-202X.2015.05.025]
[9]高兴旺,Wang Yang,梁志强,等.快速容积旋转调强治疗系统的验收测试[J].中国医学物理学杂志,2016,33(6):541.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.001]
 [J].Chinese Journal of Medical Physics,2016,33(3):541.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.001]
[10]易海云,夏兵,姚雷,等. 应用提高分辨率的MatriXX检测等中心偏移的方法简介[J].中国医学物理学杂志,2018,35(1):19.[doi:DOI:10.3969/j.issn.1005-202X.2018.01.005]
 YI Haiyun,XIA Bing,YAO Lei,et al. Brief introduction to isocenter deviation detection using MatriXX with improved resolution[J].Chinese Journal of Medical Physics,2018,35(3):19.[doi:DOI:10.3969/j.issn.1005-202X.2018.01.005]

备注/Memo

备注/Memo:
【收稿日期】2023-09-26 【基金项目】国家重点研发计划(2023YFF0719202);国家自然科学基金(12105177) 【作者简介】李昕,硕士,研究方向:快电子学,E-mail: lixin_usst2021@163.com 【通信作者】郑其斌,副教授,研究方向:快电子学,E-mail: qbzheng@usst.edu.cn
更新日期/Last Update: 2024-03-27