[1]侯凯,陈财忠,陆秀良,等.血管腔内治疗患者在数字减影血管造影中所受辐射剂量分析[J].中国医学物理学杂志,2023,40(10):1255-1259.[doi:DOI:10.3969/j.issn.1005-202X.2023.10.012]
 HOU Kai,CHEN Caizhong,LU Xiuliang,et al.Radiation dose in digital subtraction angiography for patients undergoing endovascular treatment[J].Chinese Journal of Medical Physics,2023,40(10):1255-1259.[doi:DOI:10.3969/j.issn.1005-202X.2023.10.012]
点击复制

血管腔内治疗患者在数字减影血管造影中所受辐射剂量分析()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
40卷
期数:
2023年第10期
页码:
1255-1259
栏目:
医学放射物理
出版日期:
2023-10-27

文章信息/Info

Title:
Radiation dose in digital subtraction angiography for patients undergoing endovascular treatment
文章编号:
1005-202X(2023)10-1255-05
作者:
侯凯陈财忠陆秀良曾蒙苏
复旦大学附属中山医院放射科/上海市影像医学研究所/复旦大学上海医学院影像学系, 上海 200032
Author(s):
HOU Kai CHEN Caizhong LU Xiuliang ZENG Mengsu
Department of Radiology, Zhongshan Hospital, Fudan University/Shanghai Institute of Medical Imaging/Department of Imaging, Shanghai Medical College of Fudan University, Shanghai 200032, China
关键词:
数字减影血管造影辐射剂量辐射防护
Keywords:
Keywords: digital subtraction angiography radiation dose radiation protection
分类号:
R318;R811.1
DOI:
DOI:10.3969/j.issn.1005-202X.2023.10.012
文献标志码:
A
摘要:
目的:统计血管腔内治疗患者在数字减影血管造影(DSA)中所接受的辐射剂量及影响辐射的相关因素,分析各部位接受辐射剂量的差别,为辐射防护提供参考依据。方法:收集200例受检者的全部辐射剂量值及其与剂量相关的技术参数值,按照疾病名称B型主动脉夹层、腹主动脉瘤、颈动脉狭窄、髂动脉狭窄和下肢动脉硬化闭塞症(ASO)进行分类。统计出每例受检者辐射总剂量、透视辐射剂量、DSA造影辐射剂量、射线照射总时间、透视照射时间和DSA造影时间;分别计算出相应的透视辐射剂量、造影辐射剂量与时间的比值;分别提取主动脉夹层和下肢ASO剂量DSA造影剂量报告各1例。结果:总累积辐射剂量,由高至低依次为主动脉夹层、颈动脉狭窄、腹主动脉瘤、髂动脉狭窄和下肢ASO。最高的是主动脉夹层,人均皮肤入射剂量值,为680.2 mGy,最低的是下肢ASO,为208.6 mGy。人均射线照射的时间由高至低依次为下肢ASO、颈动脉狭窄、髂动脉狭窄、腹主动脉瘤和主动脉夹层,其中最低的人均照射时间为主动脉夹层(337.8 s),下肢ASO最高,为935.4 s。辐射总剂量中的大部分是由DSA造影产生的,其中颈动脉狭窄的占比最高,占比约81.6%。单位时间DSA造影辐射剂量主动脉夹层最高,为11.24 mGy/s,下肢ASO最低,为1.38 mGy/s。照射部位体厚的增加和电子放大的使用成倍增加患者接受的辐射剂量。结论:DSA中各部位所接受的辐射剂量,胸部相对较高,其次为腹部和头颈部,外周部位最低;DSA减影所产生的辐射剂量占辐射总剂量中的绝大部分。
Abstract:
Abstract: Objective To analyze the radiation dose received by patients treated with endovascular surgery during digital subtraction angiography (DSA), investigate the related factors affecting radiation dose, and compare the difference of radiation dose received by different sites, so as to provide reference for radiation protection. Methods All the radiation doses and dose-related technical parameters of 200 patients were collected and classified according to different diseases, namely type B aortic dissection, abdominal aortic aneurysm, carotid artery stenosis, iliac artery stenosis, and lower extremity arteriosclerosis obliterans (ASO). The total radiation dose, fluoroscopy radiation dose, DSA radiation dose, total radiation exposure time, fluoroscopy exposure time, and DSA time were collected from each patient. The fluoroscopy radiation dose per unit time and contrast radiation dose per unit time were calculated. The DSA dose reports of 1 case of aortic dissection and 1 case of lower extremity ASO were analyzed. Results The total cumulative radiation dose was highest in aortic dissection (entrance skin dose per capita of 680.2 mGy), followed by carotid artery stenosis, abdominal aortic aneurysm, iliac artery stenosis, and lowest in lower extremity ASO (entrance skin dose per capita of 208.6 mGy). The exposure time per capita from high to low was lower extremity ASO, carotid artery stenosis, iliac artery stenosis, abdominal aortic aneurysm, and aortic dissection and the shortest exposure time per capita was 337.8 s in aortic dissection, and the longest was 935.4 s in lower extremity ASO. The majority of the total radiation dose was generated by DSA, among which the proportion in carotid artery stenosis (about 81.6%) was highest. The DSA radiation dose per unit time was highest in aortic dissection (11.24 mGy/s) and lowest in lower extremity ASO (1.38 mGy/s). An increase in the thickness of the irradiated site and the use of electronic amplification multiply the radiation dose received by the patient. Conclusion The radiation dose received by the chest was the highest, followed by the abdomen, head and neck, and the lowest is in the peripheral region. The radiation dose of DSA subtraction accounted for the majority of the total radiation dose.

相似文献/References:

[1]梁保辉,刘海宽,陈 志,等.基于VirtualDose模拟不同CT扫描方案的儿童眼晶体剂量[J].中国医学物理学杂志,2015,32(02):193.[doi:10.3969/j.issn.1005-202X.2015.02.009]
[2]刘建鲁,王鹏程,侯立霞,等.数字化平板血管造影系统辐射剂量优化研究进展[J].中国医学物理学杂志,2013,30(02):4015.[doi:10.3969/j.issn.1005-202X.2013.02.013]
[3]朱景雨,李惠民,蔡 静,等.基于迭代算法小儿门静脉低剂量螺旋CT成像可行性[J].中国医学物理学杂志,2015,32(05):728.[doi:doi:10.3969/j.issn.1005-202X.2015.05.026]
 [J].Chinese Journal of Medical Physics,2015,32(10):728.[doi:doi:10.3969/j.issn.1005-202X.2015.05.026]
[4]蔡静,丁茗,薛建平,等.80 kV结合迭代算法进行多层螺旋CT小儿胸部成像可行性[J].中国医学物理学杂志,2016,33(3):297.[doi:DOI:10.3969/j.issn.1005-202X.2016.03.016]
 [J].Chinese Journal of Medical Physics,2016,33(10):297.[doi:DOI:10.3969/j.issn.1005-202X.2016.03.016]
[5]沈晓波.低剂量CT技术发展及其临床应用[J].中国医学物理学杂志,2016,33(3):238.[doi:10.3969/j.issn.1005-202X.2016.03.004]
 [J].Chinese Journal of Medical Physics,2016,33(10):238.[doi:10.3969/j.issn.1005-202X.2016.03.004]
[6]王遥,霍万里,熊壮,等.TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较[J].中国医学物理学杂志,2016,33(6):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
 [J].Chinese Journal of Medical Physics,2016,33(10):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
[7]吴明群,杨聪玲,高红霞. 图像域迭代重建算法对腹部CT平扫图像质量和辐射剂量的影响[J].中国医学物理学杂志,2018,35(10):1169.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.011]
 WU Mingqun,YANG Congling,GAO Hongxia.Effects of iterative reconstruction in image space on the quality of abdominal CT plain scan image and radiation dose[J].Chinese Journal of Medical Physics,2018,35(10):1169.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.011]
[8]田光美,张广达,郭颖,等. 新型数字减影血管造影设备床旁控制器的改进研究[J].中国医学物理学杂志,2018,35(10):1193.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.016]
 TIAN Guangmei,ZHANG Guangda,GUO Ying,et al. Improvement of bedside controller of digital subtraction angiography device[J].Chinese Journal of Medical Physics,2018,35(10):1193.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.016]
[9]李广民,林志凯,彭如臣,等. 甲状腺-乳腺防护衣在乳腺X线摄影中降低辐射剂量的研究[J].中国医学物理学杂志,2019,36(6):653.[doi:DOI:10.3969/j.issn.1005-202X.2019.06.007]
 LI Guangmin,LIN Zhikai,PENG Ruchen,et al. Protective effect of protective clothing on the thyroid and mammary gland in digital mammography[J].Chinese Journal of Medical Physics,2019,36(10):653.[doi:DOI:10.3969/j.issn.1005-202X.2019.06.007]
[10]王宽,孟凯龙,田志勇. 高分辨核磁检查在颅内动脉血管疾病的应用及临床意义[J].中国医学物理学杂志,2019,36(10):1207.[doi:DOI:10.3969/j.issn.1005-202X.2019.10.018]
 WANG Kuan,MENG Kailong,TIAN Zhiyong. Application and clinical significance of high-resolution magnetic resonance imaging in diagnosis of intracranial arterial diseases[J].Chinese Journal of Medical Physics,2019,36(10):1207.[doi:DOI:10.3969/j.issn.1005-202X.2019.10.018]

备注/Memo

备注/Memo:
【收稿日期】2023-04-19 【基金项目】国家重点研发计划(2022YFC2401605);上海市临床重点专科项目(shslczdzk03202) 【作者简介】侯凯,副主任技师,研究方向:CT及DSA影像,E-mail: hou.kai@zs-hospital.sh.cn 【通信作者】曾蒙苏,博士生导师,主任医师,研究方向:放射诊断,E-mail: zeng.mengsu@zs-hospital.sh.cn
更新日期/Last Update: 2023-10-27