3台医科达加速器束流匹配后互换执行容积旋转调强放射治疗计划的剂量准确性分析()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
39卷
期数:
2022年第9期
页码:
1070-1075
栏目:
医学放射物理
出版日期:
2022-11-02

文章信息/Info

Title:
Analysis of dose accuracy for swapping VMAT plan across 3 Elekta beam-matched linear accelerators
文章编号:
1005-202X(2022)09-1070-06
作者:
李毅1吴文婧2张龙1何瑞欣1唐丰文1路咏凯1张月美1袁维1柴林燕1王龙1张晓智1
1. 西安交通大学第一附属医院肿瘤放疗科, 陕西 西安 710061; 2.西安市疾病预防控制中心, 陕西 西安 710054
Author(s):
LI Yi1 WU Wenjing2 ZHANG Long1HE Ruixin1 TANG Fengwen1 LU Yongkai1 ZHANG Yuemei1 YUAN Wei1 CHAI Linyan1 WANG Long1 ZHANG Xiaozhi1
1. Department of Radiation Oncology, the First Affiliated Hospital of Xian Jiaotong University, Xian 710061, China 2. Xian Center for Disease Control and Prevention, Xian 710054, China
关键词:
直线加速器束流匹配容积旋转调强放射治疗计划互换执行剂量准确性
Keywords:
Keywords: linear accelerator beam-matched volumetric modulated arc therapy plan swap execution dose accuracy
分类号:
R318;R815
DOI:
DOI:10.3969/j.issn.1005-202X.2022.09.003
文献标志码:
A
摘要:
目的:探讨放疗科3台加速器束流匹配后互换执行容积旋转调强放射治疗(VMAT)计划的准确性。方法:随机选取18例头颈部、胸腹部和盆腔部患者,采用Synergy1、Synergy2和VersaHD 3台加速器模型分别制作VMAT放疗计划PlanSynergy1,PlanSynergy1和PlanVersaHD。同一VMAT计划(6 MV X射线)分别在3台加速器执行,采用电离室和Delta4分别测量绝对点剂量误差和相对三维剂量γ通过率(3 mm/3%)。互换执行VMAT计划后,点剂量和相对剂量的测量结果与治疗计划系统(TPS)计算的结果比较,评估3台加速器束流匹配后VMAT计划互换执行的可行性。结果:PlanSynergy1计划分别在Synergy1、Synergy2、VersaHD执行时,测得的点剂量与TPS计算的偏差分别为-0.27%±0.87%、-0.88%±1.74%和0.37%±2.18%,测量的相对剂量与TPS计算相比,γ通过率分别为99.84%±0.31%、98.89%±1.32%和99.16%±1.12%;PlanSynergy2计划分别在Synergy1、Synergy2、VersaHD执行时测得的点剂量与TPS计算的偏差分别为0.24%±1.98%、0.15%±1.97%和-0.09%±0.66%,测量的相对剂量与TPS计算相比,γ通过率分别为98.75%±1.38%、99.77%±0.42%和99.41%±1.66%;PlanVersaHD计划分别在Synergy1、Synergy2、VersaHD执行时测得的点剂量与TPS计算的偏差分别为-0.57%±1.07%、-0.42%±2.10%和-1.55%±1.62%,测量的相对剂量与TPS计算相比,γ通过率分别为97.79%±1.61%、98.75%±1.37%和99.78%±0.60%。在3台加速器互换执行VMAT计划中,点剂量偏差均在3%以内,相对剂量偏差的γ通过率均在95%以上,均满足临床要求。结论:3台医科达加速器束流(6 MV X射线)匹配后可互换执行VMAT计划。
Abstract:
Abstract: Objective To investigate the possibility of swapping volumetric modulated arc therapy (VMAT) plan across 3 beam-matched linear accelerators. Methods Synergy1, Synergy2 and VersaHD were used to generate VMAT plans named PlanSynergy1, PlanSynergy1 and PlanVersaHD for 18 cases with the tumor located in head and neck, chest and abdomen, or pelvis. The same VMAT plan (6 MV X-ray) was executed sequentially on 3 accelerators. The absolute point dose error and relative three-dimensional dose distribution with gamma passing rate (3 mm/3%) measured by ion chamber and Delta4 were compared with the results calculated by treatment planning system for assessing the feasibility of swapping VMAT radiotherapy plan across 3 beam-matched linear accelerators. Results The deviations between measured point dose of PlanSynergy1 executed on 3 accelerators (Synergy1, Synergy2 and VersaHD) and TPS calculation were (-0.27±0.87)%, (-0.88±1.74)% and (0.37±2.18)%, respectively and the comparison between measured relative dose and TPS calculation showed that the gamma passing rates were (99.84±0.31)%, (98.89±1.32)% and (99.16±1.12)%, respectively. For PlanSynergy2, the deviations between measured point dose and TPS calculation were (0.24±1.98)%, (0.15±1.97)% and (-0.09±0.66)%, respectively and the gamma passing rates of relative dose were (98.75±1.38)%, (99.77±0.42)% and (99.41±1.66)%, respectively. For PlanVersaHD, the deviations between measured point dose and TPS calculation were (-0.57±1.07)%, (-0.42±2.10)% and (-1.55±1.62)%, respectively the gamma passing rates of relative dose were (97.79±1.61)%, (98.75±1.37)% and (99.78±0.60)%, respectively. When VMAT plan was swapped across 3 Elekta beam-matched linear accelerators, the point dose deviations were within the range of ±3%, and the gamma passing rate of relative doses were higher than 95%, meeting clinical requirements. Conclusion VMAT plan can be swapped across 3 Elekta linear accelerators after beam match (6 MV X-ray).

相似文献/References:

[1]李军,张西志,花威,等.VARIAN直线加速器IGRT全碳纤维治疗床与虚拟治疗床对高能X射线剂量的影响[J].中国医学物理学杂志,2015,32(04):479.[doi:10.3969/j.issn.1005-202X.2015.04.006]
 [J].Chinese Journal of Medical Physics,2015,32(9):479.[doi:10.3969/j.issn.1005-202X.2015.04.006]
[2]岳海振,张艺宝,刘卓伦,等. 直线加速器均整和非均整模式下射线质和射野输出因子的蒙特卡罗模拟与实测值比较[J].中国医学物理学杂志,2016,33(6):548.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.002]
 [J].Chinese Journal of Medical Physics,2016,33(9):548.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.002]
[3]周鹏,胡南,刘岩海,等.医用直线加速器无均整器下6 MV X线能谱特性的蒙特卡罗研究[J].中国医学物理学杂志,2016,33(8):761.[doi:10.3969/j.issn.1005-202X.2016.08.002]
 [J].Chinese Journal of Medical Physics,2016,33(9):761.[doi:10.3969/j.issn.1005-202X.2016.08.002]
[4]喻伟,徐胜,马宏宾,等. 基于IAEA398号报告进行直线加速器输出量校准的实践与探索[J].中国医学物理学杂志,2017,34(3):235.[doi:10.3969/j.issn.1005-202X.2017.03.004]
 [J].Chinese Journal of Medical Physics,2017,34(9):235.[doi:10.3969/j.issn.1005-202X.2017.03.004]
[5]董晓庆,林清,胡杰,等. 病人皮肤剂量监测仪在放射治疗的临床应用[J].中国医学物理学杂志,2017,34(4):363.[doi:DOI:10.3969/j.issn.1005-202X.2017.04.009]
[6]门阔,戴建荣,陈辛元,等. 双能锥形束CT线性混合技术提高相对电子密度的准确性[J].中国医学物理学杂志,2017,34(5):433.[doi:DOI:10.3969/j.issn.1005-202X.2017.05.001]
[7]夏祥1,李永宝,吴朝霞,等. Varian RapidARC直线加速器6 MeV-X线虚拟源模型的建立[J].中国医学物理学杂志,2017,34(6):561.[doi:DOI:10.3969/j.issn.1005-202X.2017.06.005]
 [J].Chinese Journal of Medical Physics,2017,34(9):561.[doi:DOI:10.3969/j.issn.1005-202X.2017.06.005]
[8]闫冰,吴爱东. 非晶硅电子射野影像装置在直线加速器日检中的应用[J].中国医学物理学杂志,2017,34(10):988.[doi:DOI:10.3969/j.issn.1005-202X.2017.10.004]
 [J].Chinese Journal of Medical Physics,2017,34(9):988.[doi:DOI:10.3969/j.issn.1005-202X.2017.10.004]
[9]李建锋,黄顺平. 实验细胞直线加速器照射方法与剂量学探讨[J].中国医学物理学杂志,2017,34(12):1211.[doi:DOI:10.3969/j.issn.1005-202X.2017.12.005]
 LI Jianfeng,HUANG Shunping. Irradiation method of experimental cell on linear accelerator and dosimetry study[J].Chinese Journal of Medical Physics,2017,34(9):1211.[doi:DOI:10.3969/j.issn.1005-202X.2017.12.005]
[10]唐志全,蒋泽,彭旭东,等. 医科达加速器的剂量监测与控制系统[J].中国医学物理学杂志,2018,35(1):9.[doi:DOI:10.3969/j.issn.1005-202X.2018.01.003]
 TANG Zhiquan,JIANG Ze,PENG Xudong,et al. Dose monitoring and control system of Elekta linear accelerator[J].Chinese Journal of Medical Physics,2018,35(9):9.[doi:DOI:10.3969/j.issn.1005-202X.2018.01.003]

备注/Memo

备注/Memo:
【收稿日期】2022-04-20 【基金项目】陕西省重点研发计划一般项目(2022SF-440);中华医学交流基金会肿瘤精准放疗星火计划临床科研基金(2019-N-11-28) 【作者简介】李毅,博士,高级工程师,研究方向:图像引导肿瘤放射治疗,E-mail: flinglee@sina.com 【通信作者】吴文婧,硕士,副主任医师,E-mail: 176223433@qq.com;张晓智,博士,主任医师,E-mail: zhang9149@sina.com
更新日期/Last Update: 2022-09-27