[1]王学敏,吴湘阳,常晓斌,等.医用直线加速器质控数据分析与管理系统-QAManager的功能设计与临床应用[J].中国医学物理学杂志,2021,38(5):545-550.[doi:DOI:10.3969/j.issn.1005-202X.2021.05.004]
 WANG Xuemin,WU Xiangyang,CHANG Xiaobin,et al.Development and clinical application of a data analysis and management system (QAManager) for accelerator quality assurance[J].Chinese Journal of Medical Physics,2021,38(5):545-550.[doi:DOI:10.3969/j.issn.1005-202X.2021.05.004]
点击复制

医用直线加速器质控数据分析与管理系统-QAManager的功能设计与临床应用()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
38卷
期数:
2021年第5期
页码:
545-550
栏目:
医学放射物理
出版日期:
2021-05-01

文章信息/Info

Title:
Development and clinical application of a data analysis and management system (QAManager) for accelerator quality assurance
文章编号:
1005-202X(2021)05-0545-06
作者:
王学敏吴湘阳常晓斌冯涛屈喜梅赵强杨迪邓佳
陕西省肿瘤医院放疗医院放射治疗区, 陕西 西安 710061
Author(s):
WANG Xuemin WU Xiangyang CHANG Xiaobin FENG Tao QU Ximei ZHAO Qiang YANG Di DENG Jia
Department of Radiotherapy, Shaanxi Provincial Cancer Hospital, Xian 710061, China
关键词:
医用直线加速器质量控制自动影像分析网页数据统计网络化管理
Keywords:
Keywords: medical accelerator quality assurance automatic image analysis web-based data statistics network-based management
分类号:
R811.1;R318
DOI:
DOI:10.3969/j.issn.1005-202X.2021.05.004
文献标志码:
A
摘要:
目的:基于Python Django框架的加速器质控自动化分析网页系统(QAManager)的开发和测试。方法:利用Python Django和MySQL数据库开发系统QAManager,实现加速器质控数据的统计分析和OBI系统影像自动分析功能。使用QAManager对TrueBeam加速器为期半年的质控结果统计分析并进行功能性测试,包括:[①]利用QAManager分析各项质控数据分布和变化趋势,对该段时间内TrueBeam的状态进行综合评估;[②]选取一年内TrueBeam OBI系统扫描Catphan504所得影像,分别使用人工、QAManager分析,并比较两者结果,分析QAManager图像自动识别算法的准确性和精确性;[③]将模体分别向前、后、左、右4个方向移动1 cm,采用QAManager自动检测,分析算法的鲁棒性。结果:QAManager界面简洁紧凑,用户能够使用QAManager自由选择需要展示的质控项目绘制曲线图,清晰显示各项目整体的分布趋势以及出现偏差最大的时间;QAManager能够准确识别到Catphan504 CBCT影像检测中各模块,除层厚(P=0.05)外,人工分析和自动分析结果比较差异没有统计学意义(P>0.05)。结论:QAManager系统准确可靠,算法能够准确地检测出加速器OBI影像系统参数,具有很强的应用性,对科室实现网络化管理具有重要意义。
Abstract:
Abstract: Objective To develop and test Python Django-based automatic analysis web system (QAManager) for accelerator quality assurance (QA). Methods QAManager was developed based on Python Django and MySQL database, with the functions of statistical analysis on accelerator QA data and automatic analysis on images obtained by on-board imaging (OBI) system. Half-a-year QA results of TrueBeam accelerator were statistically analyzed by QAManager. Besides, several functional tests were also conducted. [①] The distribution and variation trend of all QA items were analyzed by QAManager, thereby comprehensively evaluating the working state of TrueBeam accelerator during the period. [②] The results of manual analysis and QAManager analysis on Catphan504 images obtained by TrueBeam OBI system in the past year were analyzed and compared, thereby analyzing the accuracy and precision of QAManager image automatic recognition algorithm. [③ ]Catphan504 phantom which was set up on the treatment couch was deliberately shifted by 1 cm in lateral and longitudinal (no rotational) directions from the reference position, and then QAManager was used for automatic detection, thereby analyzing algorithm robustness. Results The interface of QAManager was user-friendly and compact. According to the custom QA item graphs drawn by QAManager, the rules of QA data distribution and the trends of data varying with time were pointed out and all modules in Catphan504 CBCT image detection were identified precisely by QAManager. No significant difference was found between manual analysis and QAManager analysis on Catphan504 images obtained by TrueBeam OBI system (P>0.05), except for slice thickness (P=0.05). Conclusion QAManager is accuracy and reliable, and the algorithm can be used to accurately detect all OBI parameters. Therefore, QAManager can be widely used in clinic and is vital for network-based department management.

相似文献/References:

[1]史贵连,叶福丽.PTW729二维矩阵的平面剂量验证[J].中国医学物理学杂志,2015,32(02):239.[doi:10.3969/j.issn.1005-202X.2015.02.020]
[2]张淑慧,杨敬贤,贾飞,等.肿瘤立体定向放射治疗摆位误差分析与质量控制[J].中国医学物理学杂志,2013,30(02):3988.[doi:10.3969/j.issn.1005-202X.2013.02.006]
[3]于得全,屈焕敏,邵秋菊,等.电子射野影像系统在加速器辐射野测量中的应用探讨[J].中国医学物理学杂志,2013,30(02):4001.[doi:10.3969/j.issn.1005-202X.2013.02.009]
[4]张淑慧,杨敬贤.肿瘤放射治疗摆位技术质量控制的探讨[J].中国医学物理学杂志,2013,30(06):4507.[doi:10.3969/j.issn.1005-202X.2013.06.010]
[5]张淑慧,杨敬贤,崔广余,等.放疗定位膜制作及体位固定质量控制[J].中国医学物理学杂志,2015,32(04):554.[doi:10.3969/j.issn.1005-202X.2015.04.022]
 [J].Chinese Journal of Medical Physics,2015,32(5):554.[doi:10.3969/j.issn.1005-202X.2015.04.022]
[6]刘卓伦,张艺宝,岳海振,等.医用直线加速器中心轴绝对剂量输出长期稳定性对比分析[J].中国医学物理学杂志,2016,33(1):1.[doi:DOI:10.3969/j.issn.1005-202X.2016.01.001]
 [J].Chinese Journal of Medical Physics,2016,33(5):1.[doi:DOI:10.3969/j.issn.1005-202X.2016.01.001]
[7]胡晓平,洪君.基于两种计算方法对15MV医用直线加速器机房进行辐射屏蔽分析[J].中国医学物理学杂志,2016,33(2):213.[doi:10.3969/j.issn.1005-202X.2016.02.022]
[8]李大鹏,孙遥,郑峰.质量控制检测技术在医用输液泵中的应用[J].中国医学物理学杂志,2016,33(6):639.[doi:10.3969/j.issn.1005-202X.2016.06.020]
 [J].Chinese Journal of Medical Physics,2016,33(5):639.[doi:10.3969/j.issn.1005-202X.2016.06.020]
[9]邱建峰,Bob Lei Hou,张照喜,等.医学成像质控标准器的自主化——“数字诊疗装备研发”重点专项“医学成像与放射治疗中的质量控制体模研发”[J].中国医学物理学杂志,2016,33(12):1217.[doi:10.3969/j.issn.1005-202X.2016.12.007]
 [J].Chinese Journal of Medical Physics,2016,33(5):1217.[doi:10.3969/j.issn.1005-202X.2016.12.007]
[10]魏鹏,邱杰,程品晶,等. 应用二维半导体矩阵进行螺旋断层加速器射野离轴剂量分布稳定性的分析[J].中国医学物理学杂志,2017,34(5):476.[doi:DOI:10.3969/j.issn.1005-202X.2017.05.009]
 [J].Chinese Journal of Medical Physics,2017,34(5):476.[doi:DOI:10.3969/j.issn.1005-202X.2017.05.009]
[11]刘礼东,李军烽,李书舟,等.统计过程控制方法在加速器日常输出剂量稳定性中的研究[J].中国医学物理学杂志,2021,38(2):138.[doi:DOI:10.3969/j.issn.1005-202X.2021.02.002]
 LIU Lidong,LI Junfeng,LI Shuzhou,et al.Statistical process control method in evaluating the stability of daily output dose of linear accelerator[J].Chinese Journal of Medical Physics,2021,38(5):138.[doi:DOI:10.3969/j.issn.1005-202X.2021.02.002]

备注/Memo

备注/Memo:
【收稿日期】2020-12-19 【基金项目】陕西省卫生健康科研基金(2018A007) 【作者简介】王学敏,工程师,研究方向:肿瘤放射物理,E-mail: wangxuemin2013@163.com 【通信作者】吴湘阳,主任技师,研究方向:肿瘤放射物理,E-mail: 13087566100@163.com
更新日期/Last Update: 2021-05-31