[1]鲜利勋,李光俊,肖青,等.基于食管癌放疗的剂量学参数研究几何指标评价自动勾画轮廓准确度的可行性[J].中国医学物理学杂志,2021,38(2):148-152.[doi:DOI:10.3969/j.issn.1005-202X.2021.02.004]
 XIAN Lixun,LI Guangjun,XIAO Qing,et al.Feasibility study of evaluating autosegmentation accuracy with geometric indices based on dosimetric parameters of esophageal cancer radiotherapy[J].Chinese Journal of Medical Physics,2021,38(2):148-152.[doi:DOI:10.3969/j.issn.1005-202X.2021.02.004]
点击复制

基于食管癌放疗的剂量学参数研究几何指标评价自动勾画轮廓准确度的可行性()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
38卷
期数:
2021年第2期
页码:
148-152
栏目:
医学放射物理
出版日期:
2021-02-02

文章信息/Info

Title:
Feasibility study of evaluating autosegmentation accuracy with geometric indices based on dosimetric parameters of esophageal cancer radiotherapy
文章编号:
1005-202X(2021)02-0148-05
作者:
鲜利勋12李光俊1肖青1陈黎1胡臻尧1柏森12
1.四川大学华西医院放疗科, 四川 成都 610041; 2.四川大学物理科学与技术学院, 四川 成都 610065
Author(s):
XIAN Lixun12 LI Guangjun1 XIAO Qing1 CHEN Li1 HU Zhenyao1 BAI Sen1 2
1.Department of Radiotherapy, West China Hospital of Sichuan University, Chengdu 610041, China 2. School of Physical Science and Technology, Sichuan University, Chengdu 610065, China
关键词:
食管癌放射治疗自动勾画软件危及器官几何指标剂量学参数
Keywords:
Keywords: esophageal cancer Atlas-based autosegmentation organs-at-risk geometric index dosimetric parameter
分类号:
R318;R811.1
DOI:
DOI:10.3969/j.issn.1005-202X.2021.02.004
文献标志码:
A
摘要:
目的:探讨几何指标HD、HDmean、HD95%、DSC、Jaccard间的差异,并结合食管癌放疗的剂量学参数研究几何指标评估自动勾画轮廓准确度的临床可行性。方法:选取在四川大学华西医院放疗科接受放射治疗的15例食管癌患者作为研究对象,采用ABAS软件勾画双肺、脊髓、心脏等结构,将高年资医生修改、审核后的轮廓视为参考轮廓。在参考轮廓产生的原剂量分布图上获取相应的自动勾画结构的剂量学参数,利用线性回归R?量化几何指标与剂量学参数间的相关性。结果:距离类几何指标(0~44.7 mm)波动范围较体积类指标(0.7~1.0)大;几何指标与剂量学参数间的相关性,强弱各异且不一致(45%存在相关性, P<0.05)。结论:剂量学参数深受轮廓所在位置、轮廓差异的影响,凸显了它在临床评估过程中的重要性,也表明仅用几何指标是不可靠的,建议与剂量学参数相结合。
Abstract:
Abstract: Objective To explore the differences among geometric indices HD, HDmean, HD95%, DSC and Jaccard, and to study the clinical feasibility of evaluating autosegmentation accuracy with geometric indices based on the dosimetric parameters in esophageal cancer radiotherapy. Methods Fifteen patients with esophageal cancer who received radiotherapy in Department of Radiotherapy, West China Hospital of Sichuan University were selected as the research objects, and their lungs, spinal cord and heart were outlined using Atlas-based autosegmentation software. The contours modified and reviewed by senior doctors were regarded as the references. The dosimetric parameters of the corresponding automatically-segmented structures were obtained on the original dose distribution map generated by the reference contours, and the linear regression R?was used to quantify the correlation between geometric indices and dosimetric parameters. Results The fluctuation range of distance-related geometric indices (0-44.7 mm) was larger than that of volume-related indices (0.7-1.0). The correlations between geometric indices and dosimetric parameters were different (45% correlated, P<0.05) and inconsistent. Conclusion The dosimetric parameter is deeply affected by the locations and differences of contours, which highlights its importance in clinical evaluation and shows that it is not reliable to use geometric indices only for clinical evaluation. The combination of geometric indices and dosimetric parameters is recommended for clinical evaluation.

相似文献/References:

[1]武 杰,袁杭英,欧阳蓓蕾.内旋式放射治疗用面罩固定装置的设计[J].中国医学物理学杂志,2015,32(02):265.[doi:10.3969/j.issn.1005-202X.2015.02.027]
[2]杨一威,商海焦,单国平,等.两种不同优化算法在胸部肿瘤调强放射治疗计划中的对比研究[J].中国医学物理学杂志,2015,32(02):276.[doi:10.3969/j.issn.1005-202X.2015.02.030]
[3]司 森,吴鑫全,包尚联,等.基于GPU的蒙特卡洛放疗剂量模拟[J].中国医学物理学杂志,2015,32(01):1.[doi:10.3969/j.issn.1005-202X.2015.01.001]
[4]王 文,程梦云,杨 琪,等.基于MCNP源子程序的放射治疗剂量计算验证方法[J].中国医学物理学杂志,2015,32(01):13.[doi:10.3969/j.issn.1005-202X.2015.01.004]
[5]张一戈,邱小平,陈维军,等.基于图像引导技术对头颈部肿瘤临床摆位误差的剂量学影响[J].中国医学物理学杂志,2015,32(01):25.[doi:10.3969/j.issn.1005-202X.2015.01.007]
[6]孟慧鹏,孙小喆,王 昊,等.胸部偏后背肿瘤RapidArc采用仰卧位设计治疗计划的可行性分析[J].中国医学物理学杂志,2015,32(01):31.[doi:10.3969/j.issn.1005-202X.2015.01.008]
[7]曾 彪,张九堂,席许平,等.单中心上下半野技术在胸中上段食管癌放射治疗中的剂量学分布[J].中国医学物理学杂志,2015,32(03):357.[doi:10.3969/j.issn.1005-202X.2015.03.012]
[8]庞皓文,孙小扬.基于快速自由形变的弹性配准算法在放疗CT中的应用[J].中国医学物理学杂志,2015,32(03):404.[doi:10.3969/j.issn.1005-202X.2015.03.023]
[9]陈恩乐,吴 魁,董 事,等.改变多叶准直器角度对调强放疗计划效率的影响[J].中国医学物理学杂志,2015,32(03):437.[doi:10.3969/j.issn.1005-202X.2015.03.030]
[10]贾卫娟,周一兵,谭维维,等.利用模拟机及挡铅托架进行放疗前的治疗模拟[J].中国医学物理学杂志,2014,31(01):4622.[doi:10.3969/j.issn.1005-202X.2014.01.007]
[11]时飞跃,王敏,秦伟,等.智能放疗云平台自动勾画食管癌患者心脏结构的应用[J].中国医学物理学杂志,2019,36(12):1377.[doi:DOI:10.3969/j.issn.1005-202X.2019.12.003]
 SHI Feiyue,WANG Min,et al.Application of RAIC.OIS in automatic segmentation of the heart in patients with esophageal cancer[J].Chinese Journal of Medical Physics,2019,36(2):1377.[doi:DOI:10.3969/j.issn.1005-202X.2019.12.003]
[12]沈建军,牛维纳,闫冰,等.应用4DCT测量老年食管癌患者放疗引发的肺通气功能变化[J].中国医学物理学杂志,2021,38(3):277.[doi:DOI:10.3969/j.issn.1005-202X.2021.03.002]
 SHEN Jianjun,NIU Weina,YAN Bing,et al.Measurement of pulmonary ventilation in elderly patients with esophageal cancer by 4DCT[J].Chinese Journal of Medical Physics,2021,38(2):277.[doi:DOI:10.3969/j.issn.1005-202X.2021.03.002]

备注/Memo

备注/Memo:
【收稿日期】2020-08-12 【基金项目】国家自然科学基金(81472807) 【作者简介】鲜利勋,硕士研究生,研究方向:肿瘤放疗物理,E-mail:1271322836@qq.com 【通信作者】柏森,主任技师,研究方向:肿瘤放疗物理,E-mail: baisen@scu.edu.cn
更新日期/Last Update: 2021-02-02