[1]林恒山,林增如,李燕燕,等.磁共振扩散张量成像序列对脊髓型颈椎病的诊断价值[J].中国医学物理学杂志,2019,36(11):1291-1295.[doi:DOI:10.3969/j.issn.1005-202X.2019.11.009]
 LIN Hengshan,LIN Zengru,et al.Diagnostic value of diffusion tensor magnetic resonance imaging sequence in cervical spondylotic myelopathy[J].Chinese Journal of Medical Physics,2019,36(11):1291-1295.[doi:DOI:10.3969/j.issn.1005-202X.2019.11.009]
点击复制

磁共振扩散张量成像序列对脊髓型颈椎病的诊断价值()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
36卷
期数:
2019年第11期
页码:
1291-1295
栏目:
医学影像物理
出版日期:
2019-11-25

文章信息/Info

Title:
Diagnostic value of diffusion tensor magnetic resonance imaging sequence in cervical spondylotic myelopathy
文章编号:
1005-202X(2019)11-1291-05
作者:
林恒山12林增如12李燕燕12许伟明12李铭12潘星朵12吴垠12
1.福建中医药大学附属康复医院影像科, 福建 福州 350003; 2.福建省康复技术重点实验室, 福建 福州 350003
Author(s):
LIN Hengshan1 2 LIN Zengru1 2 LI Yanyan1 2 XU Weiming1 2 LI Ming1 2 PAN Xingduo1 2 WU Yin1 2
1. Department of Imaging, the Affiliated Rehabilitation Hospital of Fujian University of Traditional Chinese Medicine, Fuzhou 350003, China; 2. Fujian Key Laboratory of Rehabilitation Technology, Fuzhou 350003, China
关键词:
脊髓型颈椎病磁共振扩散张量成像
Keywords:
cervical spondylotic myelopathy magnetic resonance diffusion tensor imaging
分类号:
R816.8
DOI:
DOI:10.3969/j.issn.1005-202X.2019.11.009
文献标志码:
A
摘要:
目的:分析3.0T磁共振(MR)扩散张量成像(DTI)序列对脊髓型颈椎病(CSM)的诊断价值。方法:选择福建中医药大学附属康复医院收治的30例CSM患者纳入观察组,另选择同期体检人群中年龄匹配的30例健康志愿者为对照组,均运用常规MRI序列及DTI技术进行扫描,运用DTI技术测量FA及ADC值,进行图像后处理及数据分析,观察组患者根据MR平扫结果分为A组(n=10,单纯硬膜囊受压)、B组(n=14,颈髓受压,信号正常)和C组(n=6,颈髓受压,T2WI高信号),分析各组FA及DA值差异,评价DTI诊断脊髓型颈椎病的诊断价值。结果:对照组脊髓C2-3、C3-4、C4-5、C5-6、C6-7节段的ADC值与FA比较差异无统计学意义(P>0.05);对照组与A、B、C组的ADC值、FA值存在显著性差异(P<0.05),B组、C组的ADC值显著高于对照组(P<0.05),FA值显著低于对照组(P<0.05),A组ADC值、FA值与对照组比较差异无统计学意义(P>0.05);从A组到C组,ADC值呈升高趋势,FA值呈降低趋势,差异显著(P<0.05);MR T2WI、DTI序列扫描FA值、MR DTI序列扫描ADC值诊断扫描诊断CSM的敏感度与特异度为20.00%(6/30)与80.00%(24/30),80.00%(24/30)与20.00%(6/30),66.67%(20/30)与30.00%(9/30)。结论:DTI较常规MRI能更早期而准确地诊断CSM,是一种显示CSM病变和观察病变修复过程的有效手段。
Abstract:
To analyze the diagnostic value of 3.0T diffusion tensor magnetic resonance imaging (MR DTI) sequence in cervical spondylotic myelopathy (CSM). Methods Thirty patients with CSM admitted to the Affiliated Rehabilitation Hospital of Fujian University of Traditional Chinese Medicine were enrolled in observation group, while 30 age-matched healthy volunteers among physical examination population were selected as control group. The routine MRI sequence and DTI technology were used for scanning, and DTI technique for measuring fractional anisotropy (FA) values and apparent diffusion coefficient (ADC) values. Image post-processing and data analysis were also performed. The patients in observation group were divided into group A (n=10, simple dural sac compression), B (n=14, cervical spinal cord compression, normal signals) and C (n=6, cervical spinal cord compression, T2WI high signals) according to the results of MR plain scan. The differences of FA values and ADC values were analyzed in each group, and the diagnostic value of DTI in CSM was evaluated. Results No statistical difference was found in the FA values and ADC values of spinal cord C2-3, C3-4, C4-5, C5-6 and C6-7 segments in control group (P>0.05). There were significant differences in FA values and ADC values among control group and groups A, B and C (P<0.05). Compared with control group, groups B and C had significantly higher ADC values (P<0.05), but obviously lower FA values (P<0.05). The FA values and ADC values in group A were similar to those in control group, without statistical significance (P>0.05). From group A to C, ADC values showed an increasing trend; while FA values showed a decreasing trend, with significant differences (P<0.05). The sensitivity and specificity of FA values obtained by MR T2WI and DTI sequence and ADC value obtained by MR DTI sequence in the diagnosis of CSM were 20.00% (6/30) and 80.00% (24/30), 80.00% (24/30) and 20.00% (6/30), and 66.67% (20/30) and 30.00% (9/30). Conclusion DTI which is an early and accurate diagnosis of CSM cervical com pared with routine MRI is an effective means to show CSM lesions and observe the pathological repair process.

相似文献/References:

[1]李金泽,李 华,喻 罡,等.基于大脑形态学和SVM的孤独症自动识别[J].中国医学物理学杂志,2014,31(06):5338.[doi:10.3969/j.issn.1005-202X.2014.06.026]
[2]黄磊,付峰,邓官华,等.磁共振拉莫尔频率下生物组织介电参数温度特性[J].中国医学物理学杂志,2015,32(06):798.[doi:doi:10.3969/j.issn.1005-202X.2015.06.009]
[3]何汶静,许玉霞,黄正宽.基于Computer Simulation Technology 的磁共振射频线圈模拟与设计[J].中国医学物理学杂志,2017,34(1):44.[doi:10.3969/j.issn.1005-202X.2017.01.009]
 [J].Chinese Journal of Medical Physics,2017,34(11):44.[doi:10.3969/j.issn.1005-202X.2017.01.009]
[4]喻伟,马永红,徐胜,等. 植入金标患者做MRI检查的安全性[J].中国医学物理学杂志,2017,34(4):377.[doi:DOI:10.3969/j.issn.1005-202X.2017.04.011]
[5]张振显,宋鹏. 脊柱结核与脊柱转移瘤的磁共振弥散加权成像影像学特征分析[J].中国医学物理学杂志,2018,35(6):676.[doi:DOI:10.3969/j.issn.1005-202X.2018.06.011]
 ZHANG Zhenxian,SONG Peng. Imaging features of magnetic resonance imaging-diffusion weighted imaging on spinal tuberculosis and spinal metastatic tumor[J].Chinese Journal of Medical Physics,2018,35(11):676.[doi:DOI:10.3969/j.issn.1005-202X.2018.06.011]
[6]王海东. Siemens Skyra3.0 T新型磁共振成像设备故障维修与保养[J].中国医学物理学杂志,2018,35(10):1217.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.021]
 WANG Haidong. Maintenance and repair of Siemens Skyra3.0 T magnetic resonance imaging apparatus[J].Chinese Journal of Medical Physics,2018,35(11):1217.[doi:DOI:10.3969/j.issn.1005-202X.2018.10.021]
[7]杨华,龚明福,邹利光,等. CL-PEG-MnFe2O4纳米胶束介导的肿瘤微血管和微淋巴管双重靶向MR成像[J].中国医学物理学杂志,2019,36(9):1034.[doi:DOI:10.3969/j.issn.1005-202X.2019.09.008]
 YANG Hua,GONG Mingfu,ZOU Liguang,et al. Magnetic resonance imaging of angiogenesis and lymphangiogenesis in tumor using dual-targeted CL-PEG-MnFe2O4 nanomicelles[J].Chinese Journal of Medical Physics,2019,36(11):1034.[doi:DOI:10.3969/j.issn.1005-202X.2019.09.008]
[8]朱熹,叶靖,王志军,等. 并行采集技术在头颅磁共振中产生伪影的原因及处理方法[J].中国医学物理学杂志,2019,36(9):1039.[doi:DOI:10.3969/j.issn.1005-202X.2019.09.009]
 ZHU Xi,YE Jing,WANG Zhijun,et al. Causes and solutions of artifacts caused by array spatial sensitivity encoding technique in brain MRI[J].Chinese Journal of Medical Physics,2019,36(11):1039.[doi:DOI:10.3969/j.issn.1005-202X.2019.09.009]
[9]杨镜全,高明勇,周新韩,等.FIESTA和SSFSE序列在胎盘植入磁共振成像技术中的应用[J].中国医学物理学杂志,2019,36(12):1444.[doi:DOI:10.3969/j.issn.1005-202X.2019.12.015]
 YANG Jingquan,GAO Mingyong,ZHOU Xinhan,et al.Applications of FIESTA and SSFSE sequences in magnetic resonance imaging of placenta increta[J].Chinese Journal of Medical Physics,2019,36(11):1444.[doi:DOI:10.3969/j.issn.1005-202X.2019.12.015]
[10]陈斐,唐澍.磁共振弥散加权成像在鉴别肝脏局灶性良恶性病变中的诊断价值[J].中国医学物理学杂志,2020,37(7):894.[doi:DOI:10.3969/j.issn.1005-202X.2020.07.018]
 CHEN Fei,TANG Shu.Diagnostic value of diffusion-weighted magnetic resonance imaging in malignant and benign hepatic focal lesions[J].Chinese Journal of Medical Physics,2020,37(11):894.[doi:DOI:10.3969/j.issn.1005-202X.2020.07.018]

备注/Memo

备注/Memo:
【收稿日期】2019-09-13 【基金项目】福建中医药大学校管科研课题(XB2017065) 【作者简介】林恒山,E-mail: 24426989@qq.com 【通信作者】林增如,副主任医师,主要从事核磁共振在脑病和脊柱康复方面的研究,E-mail: 844082633@qq.com
更新日期/Last Update: 2019-11-28