[1]吴文婧,李毅,孙玄子,等.基于4DCT和形变配准技术评估呼吸运动对肺癌立体定向放射治疗过程中剂量的影响[J].中国医学物理学杂志,2019,36(12):1406-1410.[doi:DOI:10.3969/j.issn.1005-202X.2019.12.008]
 WU Wenjing,LI Yi,SUN Xuanzi,et al.Dose variation caused by respiratory motion on SBRT for lung tumors: an analysis based on 4DCT and deformable registration[J].Chinese Journal of Medical Physics,2019,36(12):1406-1410.[doi:DOI:10.3969/j.issn.1005-202X.2019.12.008]
点击复制

基于4DCT和形变配准技术评估呼吸运动对肺癌立体定向放射治疗过程中剂量的影响()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
36卷
期数:
2019年第12期
页码:
1406-1410
栏目:
医学放射物理
出版日期:
2019-12-25

文章信息/Info

Title:
Dose variation caused by respiratory motion on SBRT for lung tumors: an analysis based on 4DCT and deformable registration
文章编号:
1005-202X(2019)12-1406-05
作者:
吴文婧1李毅2孙玄子2张晓智2孙雷焕1张斌1李军军3
1.西安市疾病预防控制中心放射卫生科, 陕西 西安 710054; 2.西安交通大学第一附属医院肿瘤放疗科, 陕西 西安 710061; 3.西安交通大学第一附属医院医学影像科, 陕西 西安 710061
Author(s):
WU Wenjing1 LI Yi2 SUN Xuanzi2 ZHANG Xiaozhi2 SUN Leihuan1 ZHANG Bin1 LI Junjun3
1. Department of Radiological Health, Xi’an Center for Disease Control and Prevention, Xi’an 710054, China; 2. Department of Radiation Oncology, the First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, China; 3. Department of Medical Imaging, the First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, China
关键词:
肺肿瘤四维CT形变配准技术呼吸曲线立体定向放射治疗剂量
Keywords:
Keywords: lung tumor four-dimensional computed tomography deformable registration respiratory motion curve stereotactic body radiotherapy dosage
分类号:
R811.1;R734.2
DOI:
DOI:10.3969/j.issn.1005-202X.2019.12.008
文献标志码:
A
摘要:
目的:探讨肺下叶肿瘤患者立体定向放射治疗(SBRT)治疗时,呼吸运动对肿瘤和正常器官受量的影响。方法:选取14例肺下叶肿瘤患者,均行平扫CT和四维CT(4DCT)扫描定位,获得平扫及10个呼吸时相的序列图像,同时记录患者放疗时的呼吸曲线,并得到各呼吸时相维持时间占比。利用MIM工作站勾画肿瘤和正常器官,基于平扫CT制定放疗计划,将3DCT计划移植到各呼吸时相的序列图像中并计算剂量,按照时间占比叠加各个时相的剂量。结果:比较平扫CT计划剂量分布和叠加剂量分布,得出相比平扫CT计划剂量。叠加剂量中,PTV平均剂量、患侧肺V20、患侧肺平均剂量、健侧肺平均剂量和全肺平均剂量的4D加权叠加均小于3D剂量,分别减小了2.37%、5.08%、5.19%、3.61%和3.46%,差异均有统计学意义(P<0.05)。结论:患者的呼吸运动导致肿瘤和肺受量的降低,但在较小的变化范围内。利用4DCT和形变配准技术,引入患者各呼吸时相维持时间占比的因素,可更合理评估呼吸运动对肺下叶肿瘤SBRT放射治疗过程中剂量的影响。
Abstract:
Abstract: Objective To discuss the effects of respiration motions on the doses to tumors and organs-at-risk in patients receiving stereotactic body radiotherapy for lung tumors in the lower lobe. Methods Fourteen patients with lung tumors in the lower lobe underwent plain CT scans and four-dimensional CT (4DCT) scans to acquire plain scanning image and sequence images of 10 respiratory phases. The percentage of time intervals of each respiratory phase in a whole respiratory motion was calculated from respiratory motion curves recorded during radiotherapy. MIM workstation was used to delineate tumors and organs-at-risks. Treatment plan was designed based on plain CT, and then 3DCT plan was ported to sequence images of each respiratory phase for dose calculation by accumulating doses based on the percentages of time intervals of each respiratory phase. Results The 4D weighted dose accumulations of the mean dose of planning target volume, the V20 and mean dose of ipsilateral lung, the mean dose of contralateral lung and the mean dose of lungs were decreased by 2.37%, 5.08%, 5.19%, 3.61% and 3.46%, respectively, compared with 3D planned doses, with statistical differences (P<0.05). Conclusion The respiratory motions of patients result in decreased doses to tumors and lungs, but the variation is within a small range. The dose variation caused by respiratory motion on SBRT for lung tumors in the lower lobe can be more accurately evaluated by utilizing 4DCT and deformable registration and introducing the percentages of time intervals of each respiratory phase

相似文献/References:

[1]邢晓汾,郭瑞嵩,傅翔宇,等.肺部肿瘤立体定向放射治疗摆位误差及靶区外扩距离[J].中国医学物理学杂志,2015,32(04):529.[doi:10.3969/j.issn.1005-202X.2015.04.017]
 [J].Chinese Journal of Medical Physics,2015,32(12):529.[doi:10.3969/j.issn.1005-202X.2015.04.017]
[2]崔建国,柏晗,王丽,等.主野数量和角度对肺癌静态IMRT计划设计的影响[J].中国医学物理学杂志,2015,32(06):806.[doi:doi:10.3969/j.issn.1005-202X.2015.06.010]
 [J].Chinese Journal of Medical Physics,2015,32(12):806.[doi:doi:10.3969/j.issn.1005-202X.2015.06.010]
[3]柏晗,等.基于四维CT下胸部肿瘤调强计划中心脏和食道的剂量评估[J].中国医学物理学杂志,2016,33(3):293.[doi:DOI:10.3969/j.issn.1005-202X.2016.03.015]
 [J].Chinese Journal of Medical Physics,2016,33(12):293.[doi:DOI:10.3969/j.issn.1005-202X.2016.03.015]
[4]李毅,唐丰文,张晓智. 基于四维CT和锥形束CT确定非小细胞肺癌放疗靶区外放边界[J].中国医学物理学杂志,2016,33(9):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]
 [J].Chinese Journal of Medical Physics,2016,33(12):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]
[5]周丁屹,蒋大振,全红,等. 四维CT扫描参数和扫描模式对CT值的影响[J].中国医学物理学杂志,2016,33(9):919.[doi:10.3969/j.issn.1005-202X.2016.09.010]
 [J].Chinese Journal of Medical Physics,2016,33(12):919.[doi:10.3969/j.issn.1005-202X.2016.09.010]
[6]高文超,王军良,周振山,等. 基于四维CT和TumorLoc软件测定肺下叶呼吸动度[J].中国医学物理学杂志,2016,33(9):944.[doi:10.3969/j.issn.1005-202X.2016.09.015]
 [J].Chinese Journal of Medical Physics,2016,33(12):944.[doi:10.3969/j.issn.1005-202X.2016.09.015]
[7]时飞跃,秦伟,陈飞,等.呼吸时相和模体位置对4D-CT图像均匀性的影响[J].中国医学物理学杂志,2020,37(1):65.[doi:DOI:10.3969/j.issn.1005-202X.2020.01.013]
 SHI Feiyue,QIN Wei,et al.Effects of respiratory phase and phantom position on uniformity of 4D-CT image[J].Chinese Journal of Medical Physics,2020,37(12):65.[doi:DOI:10.3969/j.issn.1005-202X.2020.01.013]
[8]刘卫朋,祁业东,李健,等.基于多尺度区域可靠性感知的半监督肺肿瘤分割[J].中国医学物理学杂志,2024,41(9):1078.[doi:DOI:10.3969/j.issn.1005-202X.2024.09.004]
 LIU Weipeng,QI Yedong,et al.Semi-supervised lung tumor segmentation based on multi-scale consistency and regional reliability perception[J].Chinese Journal of Medical Physics,2024,41(12):1078.[doi:DOI:10.3969/j.issn.1005-202X.2024.09.004]

备注/Memo

备注/Memo:
【收稿日期】2019-07-15 【基金项目】西安交通大学第一附属医院院基金(2018MS-25) 【作者简介】吴文婧,硕士,主要研究方向:肿瘤放疗剂量安全,E-mail: 176223433@qq.com 【通信作者】李毅,硕士,主要研究方向:肿瘤放射物理,E-mail: flinglee@sina.com