[1]戴兴,徐加利,梁保辉. 利用免洗胶片测量CT轴向和螺旋扫描的剂量分布[J].中国医学物理学杂志,2019,36(5):529-533.[doi:DOI:10.3969/j.issn.1005-202X.2019.05.007]
 DAI Xing,XU Jiali,LIANG Baohui. Using disposable film to measure the dose profiles in axial scanning and helical scanning with computed tomography[J].Chinese Journal of Medical Physics,2019,36(5):529-533.[doi:DOI:10.3969/j.issn.1005-202X.2019.05.007]
点击复制

 利用免洗胶片测量CT轴向和螺旋扫描的剂量分布()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
36卷
期数:
2019年第5期
页码:
529-533
栏目:
医学放射物理
出版日期:
2019-05-25

文章信息/Info

Title:
 Using disposable film to measure the dose profiles in axial scanning and helical scanning with computed tomography
文章编号:
1005-202X(2019)05-0529-05
作者:
 戴兴1徐加利2梁保辉1
 1.蚌埠医学院医学影像学院, 安徽 蚌埠 233000; 2.蚌埠医学院第一附属医院放射科, 安徽 蚌埠 233004
Author(s):
 DAI Xing1 XU Jiali2 LIANG Baohui1
 1. School of Medical Imaging, Benbu Medical College, Bengbu 233000, China; 2. Department of Radiology, the First Affiliated Hospital of Bengbu Medical College, Bengbu 233004, China
关键词:
 计算机断层成像免洗胶片轴向扫描螺旋扫描
Keywords:
 Keywords: computed tomography disposable film axial scanning helical scanning
分类号:
R144.1;R318
DOI:
DOI:10.3969/j.issn.1005-202X.2019.05.007
文献标志码:
A
摘要:
 目的:测量CT轴向扫描和螺旋扫描两种模式的剂量分布及其影响因素。方法:利用Gafchromic免洗胶片测量GE LightSpeed 64排CT的剂量分布。胶片经CT机扫描曝光后,利用HP scanjet 7400c扫描仪扫描获得数字图像,并利用ImageJ软件进行图像处理,以获得CT剂量分布。结果:在轴向扫描过程中,峰值半高宽与标称射束准直宽度偏差小于4 mm,视野大小和过滤器形状对轴向剂量分布的影响可以忽略。在螺旋扫描过程中,过扫描范围的大小主要与射束准直宽度有关,螺距、重建层厚和视野对过扫描范围的影响较小。结论:免洗胶片可用于快速检测CT轴向和螺旋扫描的剂量分布。
Abstract:
 Abstract: Objective To measure the dose profiles in axial scanning and helical scanning with computed tomography (CT), and investigate the related influence factors. Methods Gafchromic disposable film was used to measure the dose profile of GE LightSpeed 64 CT scanner. After being exposed by CT scanner, the disposable film was scanned with HP scanjet 7400c to obtain digital image, and then ImageJ software was applied to process the digital image for obtaining the dose profile. Results In axial scanning mode, the deviation between full width at half-maximum and nominal beam collimation width was within 4 mm, and moreover, the effects of field of view and types of filters on the dose profile in axial scanning were ignorable. In helical scanning mode, the overranging was mainly dependent on beam collimation width, and moreover, pitch, reconstruction slice thickness and field of view had trivial effects on overranging. Conclusion Disposable film is capable of rapidly measuring the dose profiles in axial scanning and helical scanning with CT.

相似文献/References:

[1]王遥,霍万里,熊壮,等.TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较[J].中国医学物理学杂志,2016,33(6):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
 [J].Chinese Journal of Medical Physics,2016,33(5):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
[2]张新,谷晓芳,王培臣,等.轻离子束治疗设备注册检验关键技术问题[J].中国医学物理学杂志,2016,33(6):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
 [J].Chinese Journal of Medical Physics,2016,33(5):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
[3]江芬芬,王培,康盛伟,等. 热释光剂量片测量肺部肿瘤放疗剂量的方法[J].中国医学物理学杂志,2016,33(6):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
 [J].Chinese Journal of Medical Physics,2016,33(5):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
[4]刘洪源,彭威,杨锐,等. 锥形束CT离线校正肺癌摆位误差[J].中国医学物理学杂志,2016,33(6):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
 [J].Chinese Journal of Medical Physics,2016,33(5):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
[5]赵彪,潘香,杨毅,等. 右乳癌保乳术后瘤床同步X线和后程电子线补量调强放疗剂量学比较[J].中国医学物理学杂志,2016,33(6):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
 [J].Chinese Journal of Medical Physics,2016,33(5):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
[6]邓南,钱建庭,刁现芬,等. 基于宽带检测放疗X-光光声效应仿体实验[J].中国医学物理学杂志,2016,33(9):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
 [J].Chinese Journal of Medical Physics,2016,33(5):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
[7]张先稳,李军,张西志,等. 宫颈癌术后5野调强放疗4个变量组合的最佳治疗模式的剂量学[J].中国医学物理学杂志,2016,33(9):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
 [J].Chinese Journal of Medical Physics,2016,33(5):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
[8]胡健,李承军,徐利明,等. 床面倾斜对剂量验证通过率的影响[J].中国医学物理学杂志,2016,33(9):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
 [J].Chinese Journal of Medical Physics,2016,33(5):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
[9]陈亚正,肖明勇,孙春堂,等. 准直器角度对宫颈癌术后VMAT计划的影响[J].中国医学物理学杂志,2016,33(9):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
 [J].Chinese Journal of Medical Physics,2016,33(5):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
[10]李毅,唐丰文,张晓智. 基于四维CT和锥形束CT确定非小细胞肺癌放疗靶区外放边界[J].中国医学物理学杂志,2016,33(9):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]
 [J].Chinese Journal of Medical Physics,2016,33(5):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]
[11]武王将,李言,杨智. 基于CT模拟数据研究多层CHO的低对比检测性能[J].中国医学物理学杂志,2018,35(12):1462.[doi:DOI:10.3969/j.issn.1005-202X.2018.12.018]
 WU Wangjiang,LI Yan,YANG Zhi. Performance of multi-slice channelized Hotelling observer for low-contrast signal detection in simulated CT data[J].Chinese Journal of Medical Physics,2018,35(5):1462.[doi:DOI:10.3969/j.issn.1005-202X.2018.12.018]

备注/Memo

备注/Memo:
 【收稿日期】2018-12-12
【基金项目】安徽高校自然科学研究重点项目(KJ2017A239);蚌埠医学院校级科研课题(byky1639)
【作者简介】戴兴,助理实验师,研究方向:医学影像技术,E-mail:382731193@qq.com
【通信作者】梁保辉,副教授,研究方向:放射诊疗中的辐射防护,E-mail:yxwlx@126.com
更新日期/Last Update: 2019-05-23