[1]胡金炎,张丽媛,刘乐乐,等. 基于EPID采用参数化梯度法测定光子束射野边界[J].中国医学物理学杂志,2018,35(11):1261-1268.[doi:DOI:10.3969/j.issn.1005-202X.2018.11.005]
 HU Jinyan,ZHANG Liyuan,LIU Lele,et al. EPID-based parameterized gradient method for photon beam field size determination[J].Chinese Journal of Medical Physics,2018,35(11):1261-1268.[doi:DOI:10.3969/j.issn.1005-202X.2018.11.005]
点击复制

 基于EPID采用参数化梯度法测定光子束射野边界()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
35卷
期数:
2018年第11期
页码:
1261-1268
栏目:
医学放射物理
出版日期:
2018-11-18

文章信息/Info

Title:
 EPID-based parameterized gradient method for photon beam field size determination
文章编号:
1005-202X(2018)11-1261-08
作者:
 胡金炎1张丽媛2刘乐乐1王学敏3裴运通1郭跃信1
 1.郑州大学第一附属医院放射治疗部, 河南 郑州 450052; 2.郑州市中心医院放疗科, 河南 郑州 450052; 3.陕西省肿瘤医院放射治疗科, 陕西 西安 710061
Author(s):
 HU Jinyan1 ZHANG Liyuan2 LIU Lele1 WANG Xuemin3 PEI Yuntong1 GUO Yuexin1
 1. Department of Radiation Oncology, the First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China; 2. Department of Radiation Oncology, Zhengzhou Central Hospital, Zhengzhou 450052, China; 3. Department of Radiotherapy, Shaanxi Provincial Cancer Hospital, Xi’an 710061, China
关键词:
 光子束电子射野影像系统参数化梯度方法射野检测质量保障
Keywords:
 Keywords: photon beam electronic portal image dosimetry parameterized gradient method field size determination quality assurance
分类号:
R312;R811.1
DOI:
DOI:10.3969/j.issn.1005-202X.2018.11.005
文献标志码:
A
摘要:
 【摘 要】 目的:探究参数化梯度方法(PGM)测量电子射野影像系统(EPID)光子束射野大小的可行性。 方法:PGM通过一个修改的双曲正切函数拟合Profile半影区。瓦里安EDGE机载aS1200采集6 MV和10 MV FF及FFF射束EPID数据,TrueBeam机载aS1000采集6 MV FF射束EPID数据。γ分析1 mm/1%标准量化PGM拟合Profile半影区与EPID测量半影区一致性。比较半高宽方法与PGM测量的FF射束射野大小,比较最大斜率方法与PGM测量的FFF射束射野大小;比较PGM在不同射束能量、不同EPID探测器类型和引入铅门位置误差后测量射野边界的稳定性和扩展性。 结果:半影区PGM拟合与EPID实测数据Pearson相关系数大于0.999,γ值小于0.2。FF射束,半高宽方法测定射野均大于PGM,且随着射野增大而增大,Profile本影去除后,两种方法测量差值显著减小;FFF射束,最大斜率方法与PGM测定射野大小差值在0.1 mm以内。PGM能够稳定测量不同能量、不同模态、不同EPID探测器类型射野边界,能够准确识别铅门1 mm位置变动。 结论:PGM可作为一种鲁棒通用的方法适用于EPID光子束射野质量保障。
Abstract:
 
Abstract: Objective To investigate the feasibility of using parameterized gradient method (PGM) to determine photon beam field size based on electronic portal image dosimetry (EPID). Methods Profile penumbra region was fitted by PGM via a modified hyperbolic tangent function. Varian EDGE aS1200 detector was used to collect the EPID data of 6 MV and 10 MV flattening-filter (FF) and flattening-filter-free (FFF) photon beams, while TrueBeam aS1000 detector was used to obtain the EPID data of 6 MV FF photon beams. Gamma analysis with 1 mm/1% criterion was used to quantitatively assess the consistency between Profile penumbra region fitted by PGM and that measured by EPID. The FF photon beam field sizes calculated by full-width at half-maximum method and those determined by PGM were compared, and the FFF photon beam field sizes obtained by maximum slope method and those obtained by PGM were also compared. By varying beam energies and types of EPID detectors and introducing Jaw position errors, the robustness and scalability of PGM for photon beam field size determination were evaluated. Results Pearson correlation coefficient between penumbra region fitted by PGM and data measured by EPID was greater than 0.999 and γ was less than 0.2. For FF beams, the field size calculated with full-width at half-maximum method were larger than that obtained with PGM, and even larger as the field size increasing. However, after subtracting the umbra region from profile, the differences in measurements between two methods were significantly reduced. For FFF beams, the differences between the field sizes calculated with maximum slope method and those obtained with PGM were within 0.1 mm. PGM achieved a stable measurement of field size at different beam energies, modalities, independent of EPID detector characteristics, and is effective in detecting Jaw errors which was within ±1 mm. Conclusion PGM can be universally applied to EPID photon beam of all modalities for quality assurance (QA).

相似文献/References:

[1]王遥,霍万里,熊壮,等.TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较[J].中国医学物理学杂志,2016,33(6):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
 [J].Chinese Journal of Medical Physics,2016,33(11):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
[2]张新,谷晓芳,王培臣,等.轻离子束治疗设备注册检验关键技术问题[J].中国医学物理学杂志,2016,33(6):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
 [J].Chinese Journal of Medical Physics,2016,33(11):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
[3]江芬芬,王培,康盛伟,等. 热释光剂量片测量肺部肿瘤放疗剂量的方法[J].中国医学物理学杂志,2016,33(6):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
 [J].Chinese Journal of Medical Physics,2016,33(11):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
[4]刘洪源,彭威,杨锐,等. 锥形束CT离线校正肺癌摆位误差[J].中国医学物理学杂志,2016,33(6):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
 [J].Chinese Journal of Medical Physics,2016,33(11):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
[5]赵彪,潘香,杨毅,等. 右乳癌保乳术后瘤床同步X线和后程电子线补量调强放疗剂量学比较[J].中国医学物理学杂志,2016,33(6):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
 [J].Chinese Journal of Medical Physics,2016,33(11):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
[6]邓南,钱建庭,刁现芬,等. 基于宽带检测放疗X-光光声效应仿体实验[J].中国医学物理学杂志,2016,33(9):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
 [J].Chinese Journal of Medical Physics,2016,33(11):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
[7]张先稳,李军,张西志,等. 宫颈癌术后5野调强放疗4个变量组合的最佳治疗模式的剂量学[J].中国医学物理学杂志,2016,33(9):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
 [J].Chinese Journal of Medical Physics,2016,33(11):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
[8]胡健,李承军,徐利明,等. 床面倾斜对剂量验证通过率的影响[J].中国医学物理学杂志,2016,33(9):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
 [J].Chinese Journal of Medical Physics,2016,33(11):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
[9]陈亚正,肖明勇,孙春堂,等. 准直器角度对宫颈癌术后VMAT计划的影响[J].中国医学物理学杂志,2016,33(9):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
 [J].Chinese Journal of Medical Physics,2016,33(11):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
[10]李毅,唐丰文,张晓智. 基于四维CT和锥形束CT确定非小细胞肺癌放疗靶区外放边界[J].中国医学物理学杂志,2016,33(9):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]
 [J].Chinese Journal of Medical Physics,2016,33(11):892.[doi:10.3969/j.issn.1005-202X.2016.09.005]

备注/Memo

备注/Memo:
 【收稿日期】2018-09-10
【作者简介】胡金炎,硕士研究生,助理工程师,研究方向:医学物理,E-mail: fcchujy@zzu.edu.cn
【通信作者】郭跃信,主任技师,研究方向:放疗物理与图像引导,E-mail: guoyx0371@126.com
更新日期/Last Update: 2018-11-22