[1]王锦红,郭道宁,卫云峰. 心肌应变与弹性模量三维成像技术在心脏瓣膜病中的应用[J].中国医学物理学杂志,2018,35(11):1291-1294.[doi:DOI:10.3969/j.issn.1005-202X.2018.11.010]
 WANG Jinhong,GUO Daoning,WEI Yunfeng. Application of myocardial strain and elastic modulus three-dimensional imaging technique in patients with valvular heart disease[J].Chinese Journal of Medical Physics,2018,35(11):1291-1294.[doi:DOI:10.3969/j.issn.1005-202X.2018.11.010]
点击复制

 心肌应变与弹性模量三维成像技术在心脏瓣膜病中的应用()
分享到:

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

卷:
35卷
期数:
2018年第11期
页码:
1291-1294
栏目:
医学影像物理
出版日期:
2018-11-18

文章信息/Info

Title:
 Application of myocardial strain and elastic modulus three-dimensional imaging technique in patients with valvular heart disease
文章编号:
1005-202X(2018)11-1291-04
作者:
 王锦红郭道宁卫云峰
 绵阳市中心医院, 四川 绵阳 621000
Author(s):
 WANG Jinhong GUO Daoning WEI Yunfeng
 Mianyang Central Hospital, Mianyang 621000, China
关键词:
 三维成像心脏瓣膜病心肌应变弹性模量
Keywords:
 Keywords: three-dimensional imaging valvular heart disease myocardial strain elastic modulus
分类号:
R445.1;R542.5
DOI:
DOI:10.3969/j.issn.1005-202X.2018.11.010
文献标志码:
A
摘要:
 目的:研究三维成像技术在心脏瓣膜病患者中的应用。 方法:选取2016年4月~2017年9月接收疑似心脏瓣膜病患者98例,按照入院先后顺序分为研究组和对照组,各49例。对照组采用二维超声检查,研究组进行三维超声成像技术检查,两组患者的病理结果与影像结果进行比较,对两组患者的左室整体应变相关参数(GLS、GCS、GRS、GLSendo、GLSepi、GCSendo、GCSepi)进行对比分析,对两组患者的心动图LVDd、LAD、LVEF相关指标进行对比分析,对两组患者的超声特征进行对比。 结果:研究组患者的病理检查结果与影像检查结果一致,对照组患者48例影像检查结果与病理结果一致。研究组患者的左室整体应变参数GLS、GCS、GRS、GLSendo、GLSepi、GCSendo、GCSepi较对照组患者低,差异有统计学意义(P<0.05)。研究组患者心动图LVDd、LAD相关指标高于对照组,LVEF指标低于对照组,差异有统计学意义(P<0.05)。研究组患者的影像显示瓣膜联合处增厚、挛缩、钙化,瓣口面积较为狭窄,且瓣口关闭时对合不严,瓣膜表面粗糙不平,可以多角度立体化观察病灶部位和病变程度。对照组患者显示瓣膜联合处增厚、挛缩、钙化,病灶边界较为模糊。 结论:三维成像技术可以立体显示心脏瓣膜病变部位和程度,为临床研究提供价值更高的信息,对瓣膜手术具有肯定的指导作用。
Abstract:
 Abstract: Objective To investigate the diagnostic value of three-dimensional imaging techniques in patients with valvular heart disease. Methods A total of 98 patients with suspected valvular heart disease who were admitted to Mianyang Central Hospital from April 2016 to September 2017 were randomly divided into study group and control group, with 49 patients in each group. Two-dimensional ultrasonic imaging technology was adopted in control group, and three-dimensional ultrasonic imaging technology in study group. The imaging results were than compared with the pathological results of the two groups of patients. The left ventricular global strain parameters (GLS, GCS, GRS, GLSendo, GLSepi, Gcsendo, GCSepi), related indexes on cardiogram (LVDd, LAD, and LVEF), and the ultrasonic features were analyzed and compared between the two groups. Results The imaging results of all patients in study group and 48 patients in control group were consistent with their pathological findings. The left ventricular global strain parameters (GLS, GCS, GRS, GLSendo, GLSepi, GCSendo, GCSepi) in study group were lower than those in control group, with statistical differences (P<0.05). Moreover, LVDd and LAD were higher and LVEF was lower in study group than in control group (P<0.05). The image manifestations of the patients in study group included the thickening, contracture, and calcification of the valve joint, narrow valve areas, and rough valve surface. The valves were unable to close properly. The location and degree of lesions could be observed at multiple angles. In control group, thickening, contracture, and calcification were observed at the valve joint, and the lesion boundary was blurred. Conclusion Three-dimensional imaging technology can stereoscopically display the location and degree of valve lesions, providing more valuable information for clinical research and guidance for valve surgery.

相似文献/References:

[1]宋小金,随 力,彭彬彬,等.基于碘对比剂的Micro-CT对离体鼠脑的三维成像[J].中国医学物理学杂志,2015,32(01):57.[doi:10.3969/j.issn.1005-202X.2015.01.014]
[2]王遥,霍万里,熊壮,等.TACE手术中不同站姿下铅眼镜和铅面罩对医生眼晶状体防护效果的蒙特卡洛模拟比较[J].中国医学物理学杂志,2016,33(6):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
 [J].Chinese Journal of Medical Physics,2016,33(11):553.[doi:DOI:10.3969/j.issn.1005-202X.2016.06.003]
[3]张新,谷晓芳,王培臣,等.轻离子束治疗设备注册检验关键技术问题[J].中国医学物理学杂志,2016,33(6):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
 [J].Chinese Journal of Medical Physics,2016,33(11):559.[doi:10.3969/j.issn.1005-202X.2016.06.004]
[4]江芬芬,王培,康盛伟,等. 热释光剂量片测量肺部肿瘤放疗剂量的方法[J].中国医学物理学杂志,2016,33(6):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
 [J].Chinese Journal of Medical Physics,2016,33(11):564.[doi:10.3969/j.issn.1005-202X.2016.06.005]
[5]刘洪源,彭威,杨锐,等. 锥形束CT离线校正肺癌摆位误差[J].中国医学物理学杂志,2016,33(6):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
 [J].Chinese Journal of Medical Physics,2016,33(11):573.[doi:10.3969/j.issn.1005-202X.2016.06.007]
[6]赵彪,潘香,杨毅,等. 右乳癌保乳术后瘤床同步X线和后程电子线补量调强放疗剂量学比较[J].中国医学物理学杂志,2016,33(6):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
 [J].Chinese Journal of Medical Physics,2016,33(11):576.[doi:10.3969/j.issn.1005-202X.2016.06.008]
[7]邓南,钱建庭,刁现芬,等. 基于宽带检测放疗X-光光声效应仿体实验[J].中国医学物理学杂志,2016,33(9):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
 [J].Chinese Journal of Medical Physics,2016,33(11):865.[doi:DOI:10.3969/j.issn.1005-202X.2016.09.001]
[8]张先稳,李军,张西志,等. 宫颈癌术后5野调强放疗4个变量组合的最佳治疗模式的剂量学[J].中国医学物理学杂志,2016,33(9):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
 [J].Chinese Journal of Medical Physics,2016,33(11):872.[doi:10.3969/j.issn.1005-202X.2016.09.002]
[9]胡健,李承军,徐利明,等. 床面倾斜对剂量验证通过率的影响[J].中国医学物理学杂志,2016,33(9):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
 [J].Chinese Journal of Medical Physics,2016,33(11):881.[doi:10.3969/j.issn.1005-202X.2016.09.003]
[10]陈亚正,肖明勇,孙春堂,等. 准直器角度对宫颈癌术后VMAT计划的影响[J].中国医学物理学杂志,2016,33(9):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]
 [J].Chinese Journal of Medical Physics,2016,33(11):885.[doi:10.3969/j.issn.1005-202X.2016.09.004]

备注/Memo

备注/Memo:
 【收稿日期】2018-07-14
【作者简介】王锦红,主治医师,研究方向:心脏及血管彩超,E-mail: chaihua008@163.com
更新日期/Last Update: 2018-11-22