Comparison of AccuContour and DeepViewer in auto-segmentation of organs-at-risk(PDF)

《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]

Issue:
2022年第3期
Page:
295-299
Research Field:
医学放射物理
Publishing date:

Info

Title:
Comparison of AccuContour and DeepViewer in auto-segmentation of organs-at-risk
Author(s):
SHU Jiong1 2 3 WANG Hongzhi1 2 3 CUI Xiangli1 3
1. Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China 2. Science Island Branch, Graduate School of University of Science and Technology of China, Hefei 230026, China 3. Radiotherapy Center, Hefei Cancer Hospital, Chinese Academy of Science, Hefei 230031, China
Keywords:
Keywords: organs-at-risk auto-segmentation AccuContour DeepViewer
PACS:
R318;R811
DOI:
DOI:10.3969/j.issn.1005-202X.2022.03.006
Abstract:
Abstract: Objective To compare and analyze the accuracies of two kinds of software (AccuContour and DeepViewer) in the auto-segmentation of organs-at-risk, thereby evaluating their applicability and superiority in the radiotherapy for different tumors. Methods A total of 60 patients with different cancer were selected from Hefei Cancer Hospital, Chinese Academy of Sciences, including nasopharyngeal cancer, lung cancer, breast cancer, and cervical cancer, each of 15 cases. The organs-at-risk in CT images were auto-segmented by a physicist using AccuContour software and DeepViewer software. Taking manual segmentation as the standard, the Dice similarity coefficient (DSC) and absolute volume difference (ΔV) were calculated and paired t test was also carried out for analyzing the differences in segmentation results obtained by different software. Results The overall DSC of the segmentation results obtained by Accucontour software and DeepViewer software were 0.90±0.11 and 0.87±0.14 (t=-5.029, P<0.05), and the overall ΔV were (13.23±18.77) and (29.89±45.27) cm3 (t=7.344, P<0.05). All the DSC of 20 organs-at-risk segmented by AccuContour was greater than 0.7, of which brain had the maximum DSC (0.99±0.00), and the right lens had the minimum DSC (0.71±0.11). The segmentation results obtained by DeepViewer showed that 18 out of 20 organs-at-risk had a DSC greater than or equal to 0.7, and that the maximum (0.98±0.00) and minimum (0.63±0.18) DSC was found in the lungs and the right femoris, respectively. The ΔV of the 13 organs segmented by AccuContour were all less than those segmented by DeepViewer. Conclusion Both two kinds of software achieve satisfactory segmentation results, and have preferable performance in the segmentation of larger organs rather than smaller organs. Moreover, AccuContour is superior to DeepViewer in segmentation performance.

References:

Memo

Memo:
-
Last Update: 2022-03-28