Research progress on cone-beam CT image-guided precise radiotherapy of breast cancer(PDF)
《中国医学物理学杂志》[ISSN:1005-202X/CN:44-1351/R]
- Issue:
- 2019年第2期
- Page:
- 163-165
- Research Field:
- 医学放射物理
- Publishing date:
Info
- Title:
- Research progress on cone-beam CT image-guided precise radiotherapy of breast cancer
- Author(s):
- CHEN Shaofang
- Department of Radiation Oncology, Zhejiang Cancer Hospital, Hangzhou 310022, China
- Keywords:
- Keywords: cone-beam computed tomography; breast cancer; precise radiotherapy; review
- PACS:
- R811.1;R737.9
- DOI:
- DOI:10.3969/j.issn.1005-202X.2019.02.008
- Abstract:
- Abstract: On-board cone-beam CT (CBCT) has been widely used in imaged-guided radiotherapy of breast cancer for measuring the setup errors. So far, numerous studies have revealed that the average setup error in CBCT image-guided radiotherapy of breast cancer is controlled within 5 mm. Compared with electronic portal image devices, CBCT has tremendous advantages, especially for large-breasted patients. However, the use of CBCT significantly increases the dose to organs-at-risk, which potentially increases the likelihood of developing a secondary malignancy. Further studies are needed to assess the benefits of CBCT in breast radiotherapy.
Last Update: 2019-02-26